Researcher profile

Louis Schofield

Louis Schofield contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2013arXiv

Rotating-crystal Malaria Diagnosis: Pre-clinical validation

Improving the efficiency of malaria diagnosis is one of the main goals of current malaria research. We have recently developed a magneto-optical (MO) method which allows high-sensitivity detection of malaria pigment (hemozoin) crystals via their magnetically induced rotation in blood. Here, we validate this technique on laboratory derived blood samples infected with \textit{Plasmodium falciparum}. Using two parasite cultures, the first containing mostly ring stages and the second corresponding to the end of the parasite life cycle, we demonstrate that our novel method can detect parasite densities as low as $\sim$40 and $\sim$10\,parasites per microliter of blood for ring and schizont stage parasites, respectively. This detection limit exceeds the performance of rapid diagnostic tests and competes with the threshold achievable by light microscopic observation of blood smears. Our method can be performed with as little as 50\,microliter of capillary blood and is sensitive to the presence of hemozoin micro-crystals down to ppm concentrations. The device, designed to a portable format for clinical and in-field tests, requires no special training of the operator or specific reagents, except for an inexpensive lysis solution to release intracellular hemozoin. Beyond diagnostics, this technique may offer an efficient tool to study hemozoin formation, trace hemozoin kinetics in the body and test susceptibility/resistance of parasites to new antimalarial drugs inhibiting hemozoin formation.