Source author record

Adam Butykai

Adam Butykai appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Architecture of nanoscale ferroelectric domains in GaMo4S8

Local-probe imaging of the ferroelectric domain structure and auxiliary bulk pyroelectric measurements were conducted at low temperatures with the aim to clarify the essential aspects of the orbitally driven phase transition in GaMo4S8, a lacunar spinel crystal that can be viewed as a spin-hole analogue of its GaV4S8 counterpart. We employed multiple scanning probe techniques combined with symmetry and mechanical compatibility analysis to uncover the hierarchical domain structures, developing on the 10-100 nm scale. The identified domain architecture involves a plethora of ferroelectric domain boundaries and junctions, including primary and secondary domain walls in both electrically neutral and charged configurations, and topological line defects transforming neutral secondary walls into two oppositely charged ones.

preprint2015arXiv

Efficient monitoring of blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method

Global research efforts have been focused on the simultaneous improvement of the efficiency and sensitivity of malaria diagnosis in resource-limited settings and for the active case detection of asymptomatic infections. A recently developed magneto-optical (MO) method allows the high-sensitivity detection of malaria pigment (hemozoin) crystals in blood via their magnetically induced rotational motion. The evaluation of the method using synthetic $β$-hematin crystals and P. falciparum in vitro cultures implies its potential for in-field diagnosis. Here, we study the performance of the method in monitoring the in vivo onset and progression of the blood stage infection using a malaria mouse model. We found that the MO method can detect the first generation of intraerythrocytic parasites at the ring stage 61-66 hours after sporozoite injection demonstrating better sensitivity than light microscopy and flow cytometry. MO measurements performed after treatment of severe P. berghei infections show that the clearance period of hemozoin in mice is approx. 5 days which indicates the feasibility of the detection of later reinfections as well. Being label and reagent-free, cost-effective and rapid, together with the demonstrated sensitivity, we believe that the MO method is a suitable candidate for in-depth clinical evaluation in endemic settings.

preprint2013arXiv

Rotating-crystal Malaria Diagnosis: Pre-clinical validation

Improving the efficiency of malaria diagnosis is one of the main goals of current malaria research. We have recently developed a magneto-optical (MO) method which allows high-sensitivity detection of malaria pigment (hemozoin) crystals via their magnetically induced rotation in blood. Here, we validate this technique on laboratory derived blood samples infected with \textit{Plasmodium falciparum}. Using two parasite cultures, the first containing mostly ring stages and the second corresponding to the end of the parasite life cycle, we demonstrate that our novel method can detect parasite densities as low as $\sim$40 and $\sim$10\,parasites per microliter of blood for ring and schizont stage parasites, respectively. This detection limit exceeds the performance of rapid diagnostic tests and competes with the threshold achievable by light microscopic observation of blood smears. Our method can be performed with as little as 50\,microliter of capillary blood and is sensitive to the presence of hemozoin micro-crystals down to ppm concentrations. The device, designed to a portable format for clinical and in-field tests, requires no special training of the operator or specific reagents, except for an inexpensive lysis solution to release intracellular hemozoin. Beyond diagnostics, this technique may offer an efficient tool to study hemozoin formation, trace hemozoin kinetics in the body and test susceptibility/resistance of parasites to new antimalarial drugs inhibiting hemozoin formation.