Source author record

Loïc Toraille

Loïc Toraille appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Widefield NV Magnetic Field Reconstruction for Probing the Meissner Effect and Critical Current Density under Pressure

The spatial distribution of a magnetic field can be determined with micrometer resolution using widefield nitrogen vacancy (NV) center magnetic imaging. Nevertheless, reconstructing the magnetic field from the raw data can be challenging due to the degeneracy of the four possible NV axes and the tremendous amount of data. While a qualitative approach is sufficient for most analyses, a quantitative analysis offers deeper insight into the physical system. Here, we apply NV widefield magnetic imaging to a HgBa$_{2}$Ca$_{2}$Cu$_{3}$O$_{8+δ}$ (Hg-1223) superconducting microcrystal at a pressure of 4 GPa. We fit the results with solutions from the Hamiltonian describing the NV center ground state and take into account the relative intensities of the resonances to determine the local magnetic field magnitude and angle. Thus, we reconstruct the temperature-dependent expulsion of the magnetic field due to the Meissner effect around the superconductor. By comparing the resulting parameters to Brandt's model, which describes the magnetic behavior of a type-II superconductor, we extract the critical current density $j_c$. Overall, this work showcases the first widefield quantitative reconstruction of the Meissner effect under pressure and an optical method to study critical current density. Thus, it provides new insights into the application of NV magnetometry to superconductivity research at high pressures.

preprint2023arXiv

NV center magnetometry up to 130 GPa as if at ambient pressure

Engineering a layer of nitrogen-vacancy (NV) centers on the tip of a diamond anvil creates a multipurpose quantum sensors array for high pressure measurements, especially for probing magnetic and superconducting properties of materials. Expanding this concept above 100 GPa appears to be a substantial challenge. We observe that deviatoric stress on the anvil tip sets a limit at 40-50 GPa for practical magnetic measurements based on optically detected magnetic resonance (ODMR) of NV centers under pressure. We show that this limit can be circumvented up to at least 130 GPa by machining a micropillar on the anvil tip to create a quasi-hydrostatic stress environment for the NV centers. This is quantified using the pressure dependence of the diamond Raman shift, the NV ODMR dependence on applied magnetic field, and NV photoluminescence spectral shift. This paves the way for direct and reliable detection of the Meissner effect in superconductors above 100 GPa, such as super-hydrides.

preprint2018arXiv

Magnetic measurements on micron-size samples under high pressure using designed NV centers

Pressure is a unique tool to tune the interplay between structural, electronic and magnetic interactions. It leads to remarkable properties of materials such as recent temperature records in superconductivity. Advanced magnetic measurements under very high pressure in the Diamond Anvil Cell (DAC) use synchrotron approaches but these are lacking a formal link to the macroscopic magnetic properties. We report an alternative method consisting in optical magnetometry based on nitrogen-vacancy (NV) centers created at the surface of a diamond anvil. We illustrate the method by two measurements realized at room and low temperature respectively: the pressure evolution of the magnetization of an iron bead up to 30 GPa showing the iron ferromagnetic collapse and the detection of the superconducting transition of MgB2 at 7 GPa.

preprint2015arXiv

Nitrogen-Vacancy Centers in Diamond for Current Imaging at the Redistributive Layer Level of Integrated Circuits

We present a novel technique based on an ensemble of Nitrogen-Vacancy (NV) centers in diamond to perform Magnetic Current Imaging (MCI) on an Integrated Circuit (IC). NV centers in diamond allow measuring the three components of the magnetic fields generated by a mA range current in an IC structure over a field of 50 x 200 μm^2 with sub-micron resolution. Vector measurements allow using a more robust algorithm than those used for MCI using Giant Magneto Resistance (GMR) or Superconducting Quantum Interference Device (SQUID) sensors and it is opening new current reconstruction prospects. Calculated MCI from these measurements shows a very good agreement with theoretical current path. Acquisition time is around 10 sec, which is much faster than scanning measurements using SQUID or GMR. The experimental set-up relies on a standard optical microscope, and the measurements can be performed at room temperature and atmospheric pressure. These early experiments, not optimized for IC, show that NV centers in diamond could become a real alternative for MCI in IC.