Source author record

Lihong V. Wang

Lihong V. Wang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2026arXiv

An Ingestible Light Source for Deep Photoacoustic Imaging

Photoacoustic tomography leverages ultrasound's deep tissue penetration to retrieve optical absorption contrast well beyond the optical diffusion limit. Conventional photoacoustic systems rely on externally delivered light and are therefore constrained by optical attenuation, limiting imaging depths to several centimeters. Here, we overcome this constraint using a compact, acoustically powered device that provides optical excitation directly from within the target medium. By exploiting the weak attenuation of low-MHz ultrasound, acoustic energy is transmitted through tissue to wirelessly power a pulsed laser diode. The emitted light pulses generate photoacoustic signals that encode local optical absorption at clinically relevant depths, which could enable imaging in regions such as the gastrointestinal tract that are inaccessible to surface-based illumination. We demonstrate this approach by imaging through a 12 cm thick phantom, establishing a pathway toward deep-tissue photoacoustic imaging.

preprint2022arXiv

Transcranial photoacoustic computed tomography of human brain function

Herein we report the first in-human transcranial imaging of brain function using photoacoustic computed tomography. Functional responses to benchmark motor tasks were imaged on both the skull-less and the skull-intact hemispheres of a hemicraniectomy patient. The observed brain responses in these preliminary results demonstrate the potential of photoacoustic computed tomography for achieving transcranial functional imaging.

preprint2020arXiv

Learning-based super interpolation and extrapolation for speckled image reconstruction

Speckles arise when coherent light interacts with biological tissues. Information retrieval from speckles is desired yet challenging, requiring understanding or mapping of the multiple scattering process, or reliable capability to reverse or compensate for the scattering-induced phase distortions. In whatever situation, insufficient sampling of speckles undermines the encoded information, impeding successful object reconstruction from speckle patterns. In this work, we propose a deep learning method to combat the physical limit: the sub-Nyquist sampled speckles (~14 below the Nyquist criterion) are interpolated up to a well-resolved level (1024 times more pixels to resolve the same FOV) with smoothed morphology fine-textured. More importantly, the lost information can be retraced, which is impossible with classic interpolation or any existing methods. The learning network inspires a new perspective on the nature of speckles and a promising platform for efficient processing or deciphering of massive scattered optical signals, enabling widefield high-resolution imaging in complex scenarios.

preprint2016arXiv

Sub-Nyquist sampling boosts targeted light transport through opaque scattering media

Optical time-reversal techniques are being actively developed to focus light through or inside opaque scattering media. When applied to biological tissue, these techniques promise to revolutionize biophotonics by enabling deep-tissue non-invasive optical imaging, optogenetics, optical tweezers and photodynamic therapy. In all previous optical time-reversal experiments, the scattered light field was well-sampled during wavefront measurement and wavefront reconstruction, following the Nyquist sampling criterion. Here, we overturn this conventional practice by demonstrating that even when the scattered field is under-sampled, light can still be focused through or inside opaque media. Even more surprisingly, we show both theoretically and experimentally that the focus achieved by under-sampling is usually about one order of magnitude brighter than that achieved by conventional well-sampling conditions. Moreover, sub-Nyquist sampling improves the signal-to-noise ratio and the collection efficiency of the scattered light. We anticipate that this newly explored under-sampling scheme will transform the understanding of optical time reversal and boost the performance of optical imaging, manipulation, and communication through opaque scattering media.

preprint2015arXiv

A constrained variable projection reconstruction method for photoacoustic computed tomography without accurate knowledge of transducer responses

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging system employs conventional piezoelectric ultrasonic transducers, the ideal photoacoustic (PA) signals are degraded by the transducers' acousto-electric impulse responses (EIRs) during the measurement process. If unaccounted for, this can degrade the accuracy of the reconstructed image. In principle, the effect of the EIRs on the measured PA signals can be ameliorated via deconvolution; images can be reconstructed subsequently by application of a reconstruction method that assumes an idealized EIR. Alternatively, the effect of the EIR can be incorporated into an imaging model and implicitly compensated for during reconstruction. In either case, the efficacy of the correction can be limited by errors in the assumed EIRs. In this work, a joint optimization approach to PACT image reconstruction is proposed for mitigating errors in reconstructed images that are caused by use of an inaccurate EIR. The method exploits the bi-linear nature of the imaging model and seeks to refine the measured EIR during the process of reconstructing the sought-after absorbed optical energy density. Computer-simulation and experimental studies are conducted to investigate the numerical properties of the method and demonstrate its value for mitigating image distortions and enhancing the visibility of fine structures.

preprint2015arXiv

Fast binarized time-reversed adapted-perturbation (b-TRAP) optical focusing inside scattering media

Light scattering inhibits high-resolution optical imaging, manipulation and therapy deep inside biological tissue by preventing focusing. To form deep foci, wavefront-shaping and time-reversal techniques that break the optical diffusion limit have been developed. For in vivo applications, such focusing must provide high gain, high speed, and a large number of spatial modes. However, none of the previous techniques meet these requirements simultaneously. Here, we overcome this challenge by rapidly measuring the perturbed optical field within a single camera exposure followed by adaptively time-reversing the phase-binarized perturbation. Consequently, a phase-conjugated wavefront is synthesized within a millisecond, two orders of magnitude shorter than the digitally achieved record. We demonstrated real-time focusing in dynamic scattering media, and extended laser speckle contrast imaging to new depths. The unprecedented combination of fast response, high gain, and large mode count makes this work a major stride toward in vivo deep tissue optical imaging, manipulation, and therapy.

preprint2015arXiv

Joint Reconstruction of Absorbed Optical Energy Density and Sound Speed Distribution in Photoacoustic Computed Tomography: A numerical Investigation

Photoacoustic computed tomography (PACT) is a rapidly emerging bioimaging modality that seeks to reconstruct an estimate of the absorbed optical energy density within an object. Conventional PACT image reconstruction methods assume a constant speed-of-sound (SOS), which can result in image artifacts when acoustic aberrations are significant. It has been demonstrated that incorporating knowledge of an object's SOS distribution into a PACT image reconstruction method can improve image quality. However, in many cases, the SOS distribution cannot be accurately and/or conveniently estimated prior to the PACT experiment. Because variations in the SOS distribution induce aberrations in the measured photoacoustic wavefields, certain information regarding an object's SOS distribution is encoded in the PACT measurement data. Based on this observation, a joint reconstruction (JR) problem has been proposed in which the SOS distribution is concurrently estimated along with the sought-after absorbed optical energy density from the photoacoustic measurement data. A broad understanding of the extent to which the JR problem can be accurately and reliably solved has not been reported. In this work, a series of numerical experiments is described that elucidate some important properties of the JR problem that pertain to its practical feasibility. To accomplish this, an optimization-based formulation of the JR problem is developed that yields a non-linear iterative algorithm that alternatingly updates the two image estimates. Heuristic analytic insights into the reconstruction problem are also provided. These results confirm the ill-conditioned nature of the joint reconstruction problem that will present significant challenges for practical applications.

preprint2014arXiv

Nonlinear photoacoustic wavefront shaping (PAWS) for single speckle-grain optical focusing in scattering media

Non-invasively focusing light into strongly scattering media, such as biological tissue, is highly desirable but challenging. Recently, wavefront shaping technologies guided by ultrasonic encoding or photoacoustic sensing have been developed to address this limitation. So far, these methods provide only acoustic diffraction-limited optical focusing. Here, we introduce nonlinear photoacoustic wavefront shaping (PAWS), which achieves optical diffraction-limited (i.e. single-speckle-grain) focusing in scattering media. We develop an efficient dual-pulse excitation approach to generate strong nonlinear photoacoustic (PA) signals based on the Grueneisen memory effect. These nonlinear PA signals are used as feedback to guide iterative wavefront optimization. By maximizing the amplitude of the nonlinear PA signal, light is effectively focused to a single optical speckle grain. Experimental results demonstrate a clear optical focus on the scale of 5-7 micrometers, which is ~10 times smaller than the acoustic focus in linear dimension, with an enhancement factor of ~6000 in peak fluence. This technology has the potential to provide highly confined strong optical focus deep in tissue for microsurgery of Parkinson's disease and epilepsy or single-neuron imaging and optogenetic activation.

preprint2014arXiv

Tracking and imaging of dynamic objects in scattering media by time-reversed adapted-perturbation (TRAP) optical focusing

The ability to steer light propagation inside scattering media has long been sought-after due to its potential widespread applications. To form optical foci inside scattering media, the only feasible strategy is to guide photons by using either implanted or virtual guide stars. However, all of these guide stars must be introduced extrinsically, either invasively or by physical contact, limiting the scope of their application. Here, we focus light inside scattering media by employing intrinsic dynamics as guide stars. By time-reversing the perturbed component of the scattered light adaptively, we concentrate light to the origin of the perturbation, where the permittivity varied spontaneously. We demonstrate dynamic light focusing onto moving targets and imaging of a time-variant object obscured by highly scattering media, without invasiveness and physical contact. Anticipated applications include all-weather optical communication with airplanes or satellites, tracking vehicles in thick fogs, and imaging and photoablation of angiogenic vessels in tumors.

preprint2013arXiv

Digital ultrasonically encoded (DUE) optical focusing into random media

Focusing light into opaque random or scattering media such as biological tissue is a much sought-after goal for biomedical applications such as photodynamic therapy, optical manipulation, and photostimulation. However, focusing with conventional lenses is restricted to one transport mean free path in scattering media, limiting both optical penetration depth and resolution. Focusing deeper is possible by using optical phase conjugation or wavefront shaping to compensate for the scattering. For practical applications, wavefront shaping offers the advantage of a robust optical system that is less sensitive to optical misalignment. Here, the phase of the incident light is spatially tailored using a phase-shifting array to pre-compensate for scattering. The challenge, then, is to determine the phase pattern which allows light to be optimally delivered to the target region. Optimization algorithms are typically employed for this purpose, with visible particles used as targets to generate feedback. However, using these particles is invasive, and light delivery is limited to fixed points. Here, we demonstrate a method for non-invasive and dynamic focusing, by using ultrasound encoding as a virtual guide star for feedback to an optimization algorithm. The light intensity at the acoustic focus was increased by an order of magnitude. This technique has broad biomedical applications, such as in optogenetics or photoactivation of drugs.

preprint2013arXiv

Full-Wave Iterative Image Reconstruction in Photoacoustic Tomography with Acoustically Inhomogeneous Media

Existing approaches to image reconstruction in photoacoustic computed tomography (PACT) with acoustically heterogeneous media are limited to weakly varying media, are computationally burdensome, and/or cannot effectively mitigate the effects of measurement data incompleteness and noise. In this work, we develop and investigate a discrete imaging model for PACT that is based on the exact photoacoustic (PA) wave equation and facilitates the circumvention of these limitations. A key contribution of the work is the establishment of a procedure to implement a matched forward and backprojection operator pair associated with the discrete imaging model, which permits application of a wide-range of modern image reconstruction algorithms that can mitigate the effects of data incompleteness and noise. The forward and backprojection operators are based on the k-space pseudospectral method for computing numerical solutions to the PA wave equation in the time domain. The developed reconstruction methodology is investigated by use of both computer-simulated and experimental PACT measurement data.