Source author record

Li Bai

Li Bai appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2026arXiv

United We Defend: Collaborative Membership Inference Defenses in Federated Learning

Membership inference attacks (MIAs), which determine whether a specific data point was included in the training set of a target model, have posed severe threats in federated learning (FL). Unfortunately, existing MIA defenses, typically applied independently to each client in FL, are ineffective against powerful trajectory-based MIAs that exploit temporal information throughout the training process to infer membership status. In this paper, we investigate a new FL defense scenario driven by heterogeneous privacy needs and privacy-utility trade-offs, where only a subset of clients are defended, as well as a collaborative defense mode where clients cooperate to mitigate membership privacy leakage. To this end, we introduce CoFedMID, a collaborative defense framework against MIAs in FL, which limits local model memorization of training samples and, through a defender coalition, enhances privacy protection and model utility. Specifically, CoFedMID consists of three modules: a class-guided partition module for selective local training samples, a utility-aware compensation module to recycle contributive samples and prevent their overconfidence, and an aggregation-neutral perturbation module that injects noise for cancellation at the coalition level into client updates. Extensive experiments on three datasets show that our defense framework significantly reduces the performance of seven MIAs while incurring only a small utility loss. These results are consistently verified across various defense settings.

preprint2020arXiv

A Learning-from-noise Dilated Wide Activation Network for denoising Arterial Spin Labeling (ASL) Perfusion Images

Arterial spin labeling (ASL) perfusion MRI provides a non-invasive way to quantify cerebral blood flow (CBF) but it still suffers from a low signal-to-noise-ratio (SNR). Using deep machine learning (DL), several groups have shown encouraging denoising results. Interestingly, the improvement was obtained when the deep neural network was trained using noise-contaminated surrogate reference because of the lack of golden standard high quality ASL CBF images. More strikingly, the output of these DL ASL networks (ASLDN) showed even higher SNR than the surrogate reference. This phenomenon indicates a learning-from-noise capability of deep networks for ASL CBF image denoising, which can be further enhanced by network optimization. In this study, we proposed a new ASLDN to test whether similar or even better ASL CBF image quality can be achieved in the case of highly noisy training reference. Different experiments were performed to validate the learning-from-noise hypothesis. The results showed that the learning-from-noise strategy produced better output quality than ASLDN trained with relatively high SNR reference.

preprint2016arXiv

Automated Segmentation of Retinal Layers from Optical Coherent Tomography Images Using Geodesic Distance

Optical coherence tomography (OCT) is a non-invasive imaging technique that can produce images of the eye at the microscopic level. OCT image segmentation to localise retinal layer boundaries is a fundamental procedure for diagnosing and monitoring the progression of retinal and optical nerve disorders. In this paper, we introduce a novel and accurate geodesic distance method (GDM) for OCT segmentation of both healthy and pathological images in either two- or three-dimensional spaces. The method uses a weighted geodesic distance by an exponential function, taking into account both horizontal and vertical intensity variations. The weighted geodesic distance is efficiently calculated from an Eikonal equation via the fast sweeping method. The segmentation is then realised by solving an ordinary differential equation with the geodesic distance. The results of the GDM are compared with manually segmented retinal layer boundaries/surfaces. Extensive experiments demonstrate that the proposed GDM is robust to complex retinal structures with large curvatures and irregularities and it outperforms the parametric active contour algorithm as well as the graph theoretic based approaches for delineating the retinal layers in both healthy and pathological images.

preprint2016arXiv

Tensor Based Second Order Variational Model for Image Reconstruction

Second order total variation (SOTV) models have advantages for image reconstruction over their first order counterparts including their ability to remove the staircase artefact in the reconstructed image, but they tend to blur the reconstructed image. To overcome this drawback, we introduce a new Tensor Weighted Second Order (TWSO) model for image reconstruction. Specifically, we develop a novel regulariser for the SOTV model that uses the Frobenius norm of the product of the SOTV Hessian matrix and the anisotropic tensor. We then adapt the alternating direction method of multipliers (ADMM) to solve the proposed model by breaking down the original problem into several subproblems. All the subproblems have closed-forms and can thus be solved efficiently. The proposed method is compared with a range of state-of-the-art approaches such as tensor-based anisotropic diffusion, total generalised variation, Euler's elastica, etc. Numerical experimental results of the method on both synthetic and real images from the Berkeley database BSDS500 demonstrate that the proposed method eliminates both the staircase and blurring effects and outperforms the existing approaches for image inpainting and denoising applications.

preprint2013arXiv

Cellular buckling in I-section struts

An analytical model that describes the interactive buckling of a thin-walled I-section strut under pure compression based on variational principles is presented. A formulation combining the Rayleigh--Ritz method and continuous displacement functions is used to derive a system of differential and integral equilibrium equations for the structural component. Numerical continuation reveals progressive cellular buckling (or snaking) arising from the nonlinear interaction between the weakly stable global buckling mode and the strongly stable local buckling mode. The resulting behaviour is highly unstable and when the model is extended to include geometric imperfections it compares excellently with some recently published experiments.

preprint2010arXiv

The Influence of Intensity Standardization on Medical Image Registration

Acquisition-to-acquisition signal intensity variations (non-standardness) are inherent in MR images. Standardization is a post processing method for correcting inter-subject intensity variations through transforming all images from the given image gray scale into a standard gray scale wherein similar intensities achieve similar tissue meanings. The lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterizability, image display, and analysis, including image segmentation. This phenomenon has been documented well; however, effects of standardization on medical image registration have not been studied yet. In this paper, we investigate the influence of intensity standardization in registration tasks with systematic and analytic evaluations involving clinical MR images. We conducted nearly 20,000 clinical MR image registration experiments and evaluated the quality of registrations both quantitatively and qualitatively. The evaluations show that intensity variations between images degrades the accuracy of registration performance. The results imply that the accuracy of image registration not only depends on spatial and geometric similarity but also on the similarity of the intensity values for the same tissues in different images.