Source author record

Lesley A. Jarvis

Lesley A. Jarvis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Comparing fast imaging techniques for individual pulse imaging by Cherenkov in vivo from electron FLASH irradiation

Objective: In this study, a fast imaging technique was developed for the first in vivo Cherenkov emission imaging from an ultra-high dose rate (UHDR) electron beam source at single pulse (360 Hz) submillimeter resolution. Approach: A CMOS camera, gated to the UHDR LINAC, imaged the Cherenkov emission profiles pulse by pulse passively during the irradiation of mice on their limbs and intestinal region. The utility of an intensifier was investigated for its effect on image quality including signal to noise and spatial resolution. Pulse by pulse variability in Cherenkov emission profile were quantified spatially and temporally. Main results: An intensifier improved the emission profile signal to noise ratio from 15 to 280, with reduced spatial resolution. The profile extended beyond of the treatment field due to the lateral scattering of the electrons in tissue and its optical properties. The CMOS camera with an intensifier detected the changes in Cherenkov emission profile during expiration and inspiration of the respiration cycle for the mice to be about 3 mm. Significance: This fast imaging technique can be utilized for in vivo intrafraction monitoring of FLASH patient treatments at single pulse resolution. It can display delivery differences during respiration, and variability in the delivered treatment's surface profile, which may perturb from the intended UHDR treatment more for pencil beam scanning systems. The technique may leverage Cherenkov emission surface profile to gate the treatment delivery via respiratory gating systems under FLASH conditions.

preprint2021arXiv

Treatment Planning System for Electron FLASH Radiotherapy: Open-source for Clinical Implementation

Purpose: A Monte Carlo (MC) beam model and its implementation in a clinical treatment planning system (TPS, Varian Eclipse) are presented for a modified ultra-high dose-rate electron FLASH radiotherapy (eFLASH-RT) LINAC. Methods: The gantry head without scattering foils or targets, representative of the LINAC modifications, was modelled in Geant4. The energy spectrum (σE) and beam source emittance cone angle (θcone) were varied to match the calculated and Gafchromic film measured central-axis percent depth dose (PDD) and lateral profiles. Its Eclipse configuration was validated with measured profiles of the open field and nominal fields for clinical applicators. eFLASH-RT plans were MC forward calculated in Geant4 for a mouse brain treatment and compared to a conventional (Conv-RT) plan in Eclipse for a human patient with metastatic renal cell carcinoma. Results: The beam model and its Eclipse configuration agreed best with measurements at σE=0.5 MeV and θcone=3.9+/-0.2 degrees to clinically acceptable accuracy (the absolute average error was within 1.5% for in-water lateral, 3% for in-air lateral, and 2% for PDD). The forward dose calculation showed dose was delivered to the entire mouse brain with adequate conformality. The human patient case demonstrated the planning capability with routine accessories in relatively complex geometry to achieve an acceptable plan (90% of the tumor volume receiving 95% and 90% of the prescribed dose for eFLASH and Conv-RT, respectively). Conclusion: To the best of our knowledge, this is the first functional beam model commissioned in a clinical TPS for eFLASH-RT, enabling planning and evaluation with minimal deviation from Conv-RT workflow. It facilitates the clinical translation as eFLASH-RT and Conv-RT plan quality were comparable for a human patient. The methods can be expanded to model other eFLASH irradiators.