Researcher profile

Leonardo Salvi

Leonardo Salvi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Practical limits for large-momentum-transfer clock atom interferometers

Atom interferometry on optical clock transitions is being pursued for numerous long-baseline experiments both terrestrially and for future space missions. Crucial to meeting these experiments' required sensitivities is the implementation of large momentum transfer ($>$10$^3\hbar k$). Here we show that to sequentially apply such a large momentum via $π$ pulses places stringent requirements on the frequency noise of the interferometry laser, finding that the linewidth is required to be considerably lower than has previously been suggested. This is due to imperfect pulse fidelity in the presence of noise and is apparent even for an atom at rest interacting with resonant light, making this a fundamental constraint on operational fidelity for a given laser and pulse sequence. Within this framework, we further present and analyse two high-power, frequency-stabilised laser sources designed to perform interferometry on the $^1$S$_0$ - $^3$P$_0$ clock transitions of cadmium and strontium, respectively operating at 332 nm and 698 nm.

preprint2021arXiv

Watt-level blue light for precision spectroscopy, laser cooling and trapping of strontium and cadmium atoms

High-power and narrow-linewidth laser light is a vital tool for atomic physics, being used for example in laser cooling and trapping and precision spectroscopy. Here we produce Watt-level laser radiation at 457.49 nm and 460.86 nm of respective relevance for the cooling transitions of cadmium and strontium atoms. This is achieved via the frequency doubling of a kHz-linewidth vertical-external-cavity surface-emitting laser (VECSEL), which is based on a novel gain chip design enabling lasing at > 2 W in the 915-928 nm region. Following an additional doubling stage, spectroscopy of the $^1S_0\to{}^1P_1$ cadmium transition at 228.89 nm is performed on an atomic beam, with all the transitions from all eight natural isotopes observed in a single continuous sweep of more than 4 GHz in the deep ultraviolet. The absolute value of the transition frequency of Cd-114 and the isotope shifts relative to this transition are determined, with values for some of these shifts provided for the first time

preprint2020arXiv

Canceling the cavity length induced phase noise in an optical ring cavity for phase shift measurement and spin squeezing

We demonstrate a new method of light phase shift measurement using a high-finesse optical ring cavity which exhibits reduced phase noise due to cavity length fluctuations. Two laser beams with a frequency difference of one cavity free spectral range are simultaneously resonant with the cavity, demonstrating noise correlations in the error signals due to the common-mode cavity length fluctuations. The differential error signal shows a 30 dB reduction in cavity noise down to the noise floor in a frequency range up to half the cavity linewidth ($δν/2 \simeq 30$ kHz). Various noise sources are analyzed and their contributions to the noise floor are evaluated. Additionally, we apply this noise-reduced phase shift measurement scheme in a simulated spin-squeezing experiment where we have achieved a factor of 40 improvement in phase sensitivity with a phase resolution of 0.7 mrad, which may remove one important barrier against attaining highly spin-squeezed states. The demonstrated method is the first reported measurement using an optical ring cavity and two independent beams, a flexible situation. This method can find direct application to non-destructive measurements in quantum systems, such as for the generation of spin-squeezed states in atom interferometers and atomic clocks.

preprint2019arXiv

Sr atom interferometry with the optical clock transition as a gravimeter and a gravity gradiometer

We characterize the performance of a gravimeter and a gravity gradiometer based on the $^{1}$S$_{0}$-$^3$P$_0$ clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity of $1.7\times10^{-5}$, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiometer configuration, a differential phase sensitivity of 1.53~rad/$\sqrt{Hz}$ was achieved at an artificially introduced differential phase of $π/2$~rad. We experimentally investigated the effects of the contrast and visibility based on various parameters and achieve a total interferometry time of 30~ms, which is longer than previously reported for such interferometers. The characterization and determined limitations of the present apparatus employing $^{88}$Sr atoms provides a guidance for the future development of large-scale clock-transition gravimeters and gravity gradiometers with alkali-earth and alkali-earth-like atoms (e.g., $^{87}$Sr, Ca, Yb).