Source author record

Lawrence T. Lin

Lawrence T. Lin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam

Prime-Cam is a first-generation instrument for the Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) Facility. The 850$~$GHz module for Prime-Cam will probe the highest frequency of all the instrument modules. We describe the parameter space of the 850$~$GHz optical system between the F$λ$ spacing, beam size, pixel sensitivity, and detector count. We present the optimization of an optical design for the 850$~$GHz instrument module for CCAT-prime. We further describe the development of the cryogenic RF chain design to accommodate $>$30 readout lines to read 41,400 kinetic inductance detectors (KIDs) within the cryogenic testbed.

preprint2022arXiv

CCAT-prime: The Optical Design for the Epoch of Reionization Spectrometer

The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity mapping of the 158 $μ$m [CII] line in aggregates of star-forming galaxies between redshifts of 3.5 and 8 to trace the evolution of structure in the universe during the epoch of reionization. Here we present the optical design of the module including studies of the optical quality and other key parameters at the image surface. In order to achieve the required resolving power (R$\sim$100) with the FPI, it is important to have a highly collimated beam at the Lyot stop of the system; the optimization process to achieve this goal with four lenses instead of three as used in other Prime-Cam modules is outlined. As part of the optimization, we test the effect of replacing some of the aspheric lenses with biconic lenses in this Crossed Dragone design and find that the biconic lenses tend to improve the image quality across the focal plane of the module.