Source author record

Laura Maugeri

Laura Maugeri appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2024arXiv

Influence of scanning plane on Human Spinal Cord functional Magnetic Resonance echo planar imaging

BACKGROUND: Functional Magnetic Resonance Imaging (fMRI) is based on the Blood Oxygenation Level Dependent contrast and has been exploited for the indirect study of the neuronal activity within both the brain and the spinal cord. However, the interpretation of spinal cord fMRI (scfMRI) is still controversial and its diffusion is rather limited because of technical limitations. Overcoming these limitations would have a beneficial effect for the assessment and follow-up of spinal injuries and neurodegenerative diseases. PURPOSE: This study was aimed at systematically verify whether sagittal scanning in scfMRI using EPI readout is a viable alternative to the more common axial scanning, and at optimizing a pipeline for EPI-based scfMRI data analysis, based on Spinal Cord Toolbox (SCT). METHODS: Forty-five healthy subjects underwent MRI acquisition in a Philips Achieva 3T MRI scanner. T2*-weighted fMRI data were acquired using a GE-EPI sequence along sagittal and axial planes during an isometric motor task. Differences on benchmarks were assessed via paired two-sample t-test at p=0.05. RESULTS: We investigated the impact of the acquisition strategy by means of various metrics such as Temporal Signal to Noise Ratio (tSNR), Dice Coefficient to assess geometric distortions, Reproducibility and Sensitivity. tSNR was higher in axial than in sagittal scans, as well as reproducibility within the whole cord mask (t=7.4, p<0.01) and within the GM mask (t=4.2, p<0.01). The other benchmarks, associated with distortion and functional response, showed no difference between images obtained along the axial and sagittal planes. CONCLUSIONS: Quantitative metrics of data quality suggest that axial scanning would be the optimal choice. We conclude that axial acquisition is advantageous specially to mitigate the effects of physiological noise and to minimize inter-subject variance.

preprint2013arXiv

Temperature dependent local atomic displacements in Ru substituted SmFe_{1-x}Ru_{x}AsO_{0.85}F_{0.15} superconductors

Local structure of SmFe$_{1-x}$Ru$_x$AsO$_{0.85}$F$_{0.15}$ ($x$ = 0.0, 0.05, 0.25 and 0.5) superconductors has been investigated by temperature dependent As $K$-edge extended x-ray absorption fine structure. The effect of Ru substitution remains confined to the iron-arsenide layer but neither the static disorder nor the Fe-As bond strength suffers any change for $x \le$ 0.25. With further Ru substitution the static disorder increases while the Fe-As bond strength remains unchanged. Also, the Ru-As distance ($\sim$2.42 Å), different from the Fe-As distance ($\sim$2.39 Å), does not show any change in its force constant with the Ru substitution. These observations suggest that the SmFe$_{1-x}$Ru$_x$AsO$_{0.85}$F$_{0.15}$ system breaks down to coexisting local electronic phases on isoelectric substitution in the active FeAs layer.