Researcher profile

L. Valdez

L. Valdez contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

GT strengths and electron-capture rates for pf-shell nuclei of relevance for late stellar evolution

This paper presents a systematic evaluation of the ability of theoretical models to reproduce experimental Gamow-Teller transition strength distributions measured via (n,p)-type charge-exchange reactions at intermediate beam energies. The focus is on transitions from stable nuclei in the pf shell (45<A<64). The impact of deviations between experimental and theoretical Gamow-Teller strength distributions on derived stellar electron-capture rates at densities and temperatures of relevance for Type Ia and Type II supernovae is investigated. The theoretical models included in the study are based on the shell-model, using the KB3G and GXPF1a interactions, and quasiparticle random-phase approximation (QRPA) using ground-state deformation parameters and masses from the finite-range droplet model.

preprint2012arXiv

LENDA, a Low Energy Neutron Detector Array for experiments with radioactive beams in inverse kinematics

The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Lab- oratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its design has been motivated by the need to study the spin-isospin response of unstable nuclei using (p, n) charge-exchange reactions at intermediate energies (> 100 MeV/u). It can be used, however, for any reaction study that involves emission of low energy neutrons (150 keV - 10 MeV). The array consists of 24 plastic scintillator bars and is capable of registering the recoiling neutron energy and angle with high detection efficiency. The neutron energy is determined by the time-of-flight technique, while the position of interaction is deduced using the timing and energy information from the two photomultipliers of each bar. A simple test setup utilizing radioactive sources has been used to characterize the array. Results of test measurements are compared with simulations. A neutron energy threshold of < 150 keV, an intrinsic time (position) resolution of \sim 400 ps (\sim 6 cm) and an efficiency > 20 % for neutrons below 4 MeV have been obtained.