Source author record

L. Robison

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
4topics
4close collaborators

Published work

3 publications

preprint2020arXiv

Measurement of the Photon Beam Asymmetry in γ⃗p→K+Σ0\vecγ p\to K^+Σ^0 at Eγ=8.5E_γ = 8.5 GeV

We report measurements of the photon beam asymmetry ΣΣ for the reaction γ⃗p→K+Σ0\vecγ p\to K^+Σ^0(1193) using the GlueX spectrometer in Hall D at Jefferson Lab. Data were collected using a linearly polarized photon beam in the energy range of 8.2-8.8 GeV incident on a liquid hydrogen target. The beam asymmetry ΣΣ was measured as a function of the Mandelstam variable tt, and a single value of ΣΣ was extracted for events produced in the uu-channel. These are the first exclusive measurements of the photon beam asymmetry ΣΣ for the reaction in this energy range. For the tt-channel, the measured beam asymmetry is close to unity over the tt-range studied, −t=(0.1−1.4) -t=(0.1-1.4)~(GeV/cc)2^{2}, with an average value of Σ=1.00±0.05Σ= 1.00\pm 0.05. This agrees with theoretical models that describe the reaction via the natural-parity exchange of the K∗K^{*}(892) Regge trajectory. A value of Σ=0.41±0.09Σ= 0.41 \pm 0.09 is obtained for the uu-channel integrated up to −u=2.0-u=2.0~(GeV/cc)2^{2}.

preprint2020arXiv

The GlueX Beamline and Detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 μμs. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

preprint2016arXiv

First Results from The GlueX Experiment

The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of π0π^{0}, ηη and ωω mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the ρρ has been observed.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.