Researcher profile

L. Robinson

L. Robinson contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2026arXiv

Calibrating Mid-Infrared Emission Features As Diagnostics of Star Formation in Infrared-Luminous Galaxies via Radiative Transfer Modeling

Luminous infrared galaxies are key sites of obscured stellar mass assembly at z > 0.5. Their star formation rates (SFRs) are often estimated using the luminosities of the 6.2 micron and 11.2 micron polycyclic aromatic hydrocarbon (PAH) features, or those of the [Ne II] and [Ne III] fine-structure lines, as they are minimally affected by obscuration. It is uncertain whether the calibration of these features as SFR tracers depends on the starburst bolometric luminosity or the level of Active Galactic Nucleus (AGN) activity. We here investigate the relationship between the luminosities of PAH and Neon lines with star formation rate for highly luminous objects using radiative transfer modeling and archival observations of 42 local Ultraluminous (>= 10^12 L_sun) Infrared Galaxies (ULIRGs). We find that PAH and [Ne II] features arise mainly in star-forming regions, with small contributions from the AGN or host, but that the [Ne III] line has a mixed contribution from both star formation and AGN activity. We present relations between L_PAH and L_NeII, and both starburst luminosity and SFR. We find relations for lower luminosity (L_IR ~= 10^10-10^12 L_sun) systems underestimate the SFRs in local ULIRGs by up to ~1 dex. The 6.2 micron and 11.2 micron PAH features, and the [Ne II] line, are thus good tracers of SFR in ULIRGs. We do not find that a more luminous AGN affects the relationship between SFR and PAH or Neon luminosity, but that it can make PAH emission harder to discern. Our results and derived relations are relevant to studies of star-forming and composite galaxies at z < 3 with the James Webb Space Telescope.

preprint2022arXiv

Multitube monitors: a new-generation of neutron beam monitors

With the renewal of many neutron science instruments and the commissioning of new neutron facilities, there is a rising demand for improved neutron beam monitoring systems with reduced beam perturbations and higher counting rate capability. Fission chambers are the most popular beam monitors; however, their use on some instruments may be prevented by the background generated by fast neutrons emitted during neutron captures in 235U and by neutrons scattered in the material of the fission chamber. Multitube detectors, on the other hand, offer a good alternative with minimum beam perturbations. The purpose of this paper is to report and analyse the results of the measurements performed with several Multitubes used for beam monitoring. We show that the transparency of Multitube beam monitors is 97.6 +/-0.4 %, and that their detection efficiency is uniform, with a deviation from the mean value < 0.7%. A counting rate reduction of 10% due to pile-up effects is measured at a rate of 550 kHz. In addition to neutron beam intensity monitoring, the Multitube can be configured for 1-dimensional or 2-dimensional localisation. We present the preliminary results of these additional functionalities.

preprint2021arXiv

Time- and energy-resolved effects in the boron-10 based Multi-Grid and helium-3 based thermal neutron detectors

The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $μ$eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ~ $μ$s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of $μ$s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.

preprint2021arXiv

uRANIA-V: an innovative solution for neutron detection in homeland security

Detection of neutrons is becoming of the utmost importance, especially in the studies of radioactive waste and in homeland security applications. The crisis of 3He availability has required the development of innovative techniques. One solution is to develop light gas detectors for neutron counting to be used as portals for ports and airports. The neutron is converted on the Boron-coated cathode, releasing a charged particle, whose passage can be identified by the gas detector. While several technologies have been deployed in the past, the project μRANIA-V ( μRwell Advanced Neutron Identification Apparatus) aims to detect thermal neutrons by means of the μRwell technology, an innovative gas detector. The goal is to produce tiles to operate as portals in homeland security or for radioactive waste management. The technological transfer towards the industry has started, thus the production can be cost-effective also owing to a construction process relatively easier compared to similar apparatus. By reading directly the signals from the amplification stage, the neutrons can be counted with simplified electronics further reducing the total cost. In this paper, the project will be described, with details on the μRwell technology and on the neutron counting, on the test beam performed, and on the future plans.

preprint2020arXiv

Multilayer $^{10}B$-RPC neutron imaging detector

Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap $^{10}B$-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer $^{10}B$-RPCs detector with a stack of ten double-gap hybrid RPCs. A description of the detector design and the results of its characterization performed at the TREFF neutron beamline at the FRM II neutron facility are presented. The results demonstrate that the detection efficiency exceeds 60% for neutrons with a wavelength of 4.7 Å and the spatial resolution (FWHM) is about 0.25 mm and 0.35 mm in the X and Y direction, respectively.

preprint2020arXiv

The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer

The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scaled-down demonstrator of Estia. The results of these tests are discussed. It will be shown how the characteristics of the Multi-Blade detector are features that allow the focusing reflectometry operation mode. Additionally the performance of the Multi-Blade, in terms of rate capability, exceeds current state-of-the-art technology. The improvements with respect to the previous prototypes are also highlighted; from background considerations to the linear and angular uniformity response of the detector.

preprint2020arXiv

u-RANIA: a neutron detector based on μ-RWELL technology

In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($μ$ -RWELL) technology. The $μ$ -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B$_4$C on the copper surface of the cathode allows the thermal neutrons detection through the release of $^7$Li and $α$ particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the $^3$He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.