Source author record

L. M. Pant

L. M. Pant appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

18works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

18 published item(s)

preprint2023arXiv

Background measurements and detector response studies for ISMRAN experiment

We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) experiment at very short baseline located at Dhruva research reactor facility. It is enclosed by a shielding made of 10 cm thick lead and 10 cm thick borated polyethylene to minimize the backgrounds and is mounted on a movable base structure, situated at $\sim$ 13 m away from the reactor core. These measurements are useful in the context of the ISMRAN detector setup that will be used to detect the reactor $\mathrm{\overlineν_{e}}$ and measure its energy spectrum through the inverse beta decay (IBD) process. In this paper, we present the energy resolution model and energy non-linearity model of PSB and the cosmogenic muon-induced background, based on the sum of their energy depositions and number of hit bars. Reconstructed sum energy spectrum and number of hit bars distribution for $\mathrm{{}^{22}Na}$ radioactive source has been compared with Geant4 based Monte Carlo simulations. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.

preprint2022arXiv

Cosmic ray measurements using the ISMRAN setup in a non-reactor environment

The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muons has been measured and compared with Monte Carlo expectations. The detector setup was further used to measure the lifetime distribution of stopped muons and extract their rates inside the detector matrix. The measured spectra of decaying muons and associated electrons show a good agreement with the MC simulations performed through GEANT4 simulation.

preprint2020arXiv

Active-sterile neutrino mixing constraint using reactor antineutrinos with the ISMRAN set-up

In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near and far positions from the given reactor core. Results extracted in the later case are independent of the theoretical prediction of the reactor anti-neutrino spectrum and detector related systematic uncertainties. Our analysis shows that the results obtained from the measurement carried out at a combination of the near and far detector positions are improved significantly at higher $Δm^{2}_{41}$ compared to the ones obtained with the measurement at a single detector position only. It is found that the best possible combination of near and far detector positions from a 100 MW$_{th}$ power DHRUVA research reactor core are 7 m and 9 m, respectively, for which ISMRAN set-up can exclude in the range 1.4 $eV^{2} \leq Δm^{2}_{41} \leq$ 4.0 $eV^{2}$ of reactor antineutrino anomaly region along with the present best-fit point of active-sterile neutrino oscillation parameters. At those combinations of detector positions, the ISMRAN set-up can observe the active sterile neutrino oscillation with a 95$\%$ confidence level provided that $\sin^{2}2θ_{14}\geq 0.09$ at $Δm^{2}_{41}$ = 1 eV$^{2}$ for an exposure of 1 ton-yr. The active-sterile neutrino mixing sensitivity can be improved by about 22\% at the same exposure by placing the detector at near and far distances of 15 m and 17 m, respectively, from the compact proto-type fast breeder reactor (PFBR) facility which has a higher thermal power of 1250 MW$_{th}$.

preprint2020arXiv

Machine learning technique to improve anti-neutrino detection efficiency for the ISMRAN experiment

The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and delayed neutron from IBD will provide the signature of $\barν_e$ event in ISMRAN. The number of segments with energy deposit ($\mathrm{N_{bars}}$) and sum total of these deposited energies are used as discriminants for identifying prompt positron event and delayed neutron capture event. However, a simple cut based selection of above variables leads to a low $\barν_e$ signal detection efficiency due to overlapping region of $\mathrm{N_{bars}}$ and sum energy for the prompt and delayed events. Multivariate analysis (MVA) tools, employing variables suitably tuned for discrimination, can be useful in such scenarios. In this work we report the results from an application of artificial neural network -- the multilayer perceptron (MLP), particularly the Bayesian extension -- MLPBNN, to the simulated signal and background events in ISMRAN. The results from application of MLP to classify prompt positron events from delayed neutron capture events on Hydrogen, Gadolinium nuclei and also from the typical reactor $γ$-ray and fast neutron backgrounds is reported. An enhanced efficiency of $\sim$91$\%$ with a background rejection of $\sim$73$\%$ for prompt selection and an efficiency of $\sim$89$\%$ with a background rejection of $\sim$71$\%$ for the delayed capture event, is achieved using the MLPBNN classifier for the ISMRAN experiment.

preprint2018arXiv

High Rate RPC detector for LHC

The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\ {\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.

preprint2016arXiv

Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.

preprint2016arXiv

R&D towards the CMS RPC Phase-2 upgrade

The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.

preprint2015arXiv

A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.

preprint2015arXiv

Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data

A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.

preprint2014arXiv

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.

preprint2012arXiv

Transparency ratio in γA -> η' A' and the in-medium η' width

The photoproduction of η'-mesons off different nuclei has been measured with the CBELSA/TAPS detector system for incident photon energies between 1500 - 2200 MeV. The transparency ratio has been deduced and compared to theoretical calculations describing the propagation of η'-mesons in nuclei. The comparison indicates a width of the η' -meson of the order of Γ= 15-25 MeV at ρ=ρ_0 for an average momentum p_{η'} = 1050 MeV/c, at which the η'-meson is produced in the nuclear rest frame. The inelastic η' N cross section is estimated to be 3 - 10 mb. Parameterizing the photoproduction cross section of η'-mesons by σ(A) = σ_0 A^α, a value of α= 0.84\pm0.03 has been deduced.

preprint2011arXiv

Photoproduction of $ω$ mesons on nuclei near the production threshold

The photoproduction of $ω$ mesons on LH_2, C and Nb has been studied for incident photon energies from 900 to 1300 MeV using the CB/TAPS detector at ELSA. The $ω$ line shape does not show any significant difference between the LH_2 and the Nb targets. The data are compared with results of transport calculations that predict a sensitivity of the $ω$ line shape to in-medium modifications near the production threshold on a free nucleon of $E_γ^{lab}$ = 1109 MeV.}

preprint2011arXiv

Photoproduction of Neutral Pions off Protons

Photoproduction of neutral pions has been studied with the CBELSA/TAPS detector in the reaction $γp\to pπ^0$ for photon energies between 0.85 and 2.50 GeV. The $π^0$ mesons are observed in their dominant neutral decay mode: $π^0\toγγ$. For the first time, the differential cross sections cover the very forward region, $θ_{\rm c.m.}<60^\circ$. A partial-wave analysis of these data within the Bonn-Gatchina framework observes the high-mass resonances $G_{17}$(2190), $D_{13}$(2080), and $D_{15}$(2070).

preprint2011arXiv

Quasi-free photoproduction of eta-mesons off the deuteron

Precise data for quasi-free photoproduction of $η$ mesons off the deuteron have been measured at the Bonn ELSA accelerator with the combined Crystal Barrel/TAPS detector for incident photon energies up to 2.5 GeV. The $η$-mesons have been detected in coincidence with recoil protons and neutrons. Possible nuclear effects like Fermi motion and re-scattering can be studied via a comparison of the quasi-free reaction off the bound proton to $η$-production off the free proton. No significant effects beyond the folding of the free cross section with the momentum distribution of the bound protons have been found. These Fermi motion effects can be removed by an analysis using the invariant mass of the $η$-nucleon pairs reconstructed from the final state four-momenta of the particles. The total cross section for quasi-free $η$-photoproduction off the neutron reveals even without correction for Fermi motion a pronounced bump-like structure around 1 GeV of incident photon energy, which is not observed for the proton. This structure is even narrower in the invariant mass spectrum of the $η$-neutron pairs. Position and width of the peak in the invariant mass spectrum are $W\approx 1665$ MeV and FWHM $Γ\approx 25$ MeV. The data are compared to the results of different models.

preprint2010arXiv

In-medium $ω$ mass from the $γ+ Nb \to π^{0}γ+ X$ reaction

Data on the photoproduction of $ω$ mesons on nuclei have been re-analyzed in a search for in-medium modifications. The data were taken with the Crystal Barrel(CB)/TAPS detector system at the ELSA accelerator facility in Bonn. First results from the analysis of the data set were published by D. Trnka et al. in Phys. Rev. Lett 94 (2005) 192303 \cite{david}, claiming a lowering of the $ω$ mass in the nuclear medium by 14$%$ at normal nuclear matter density. The extracted $ω$ line shape was found to be sensitive to the background subtraction. For this reason a re-analysis of the same data set has been initiated and a new method has been developed to reduce the background and to determine the shape and absolute magnitude of the background directly from the data. Details of the re-analysis and of the background determination are described. The $ω$ signal on the $Nb$ target, extracted in the re-analysis, does not show a deviation from the corresponding line shape on a $LH_2$ target, measured as reference. The earlier claim of an in-medium mass shift is thus not confirmed. The sensitivity of the $ω$ line shape to different in-medium modification scenarios is discussed.

preprint2010arXiv

Measurement of the Beam Asymmetry $Σ$ in the Forward Direction for pi0 Photoproduction

Photoproduction of neutral pions has been studied with the CBELSA/TAPS detector for photon energies between 0.92 and 1.68~GeV at the electron accelerator ELSA. The beam asymmetry~$Σ$ has been extracted for $115^\circ < θ_{\rm c.m.} < 155^\circ$ of the $π^0$~meson and for $θ_{\rm c.m.} < 60^\circ$. The new beam asymmetry data improve the world database for photon energies above 1.5~GeV and, by covering the very forward region, extend previously published data for the same reaction by our collaboration. The angular dependence of $Σ$ shows overall good agreement with the SAID parameterization.

preprint2010arXiv

Photoproduction of $η'$-mesons off the deuteron

Quasi-free photoproduction of $η'$ mesons off nucleons bound in the deuteron has been measured with the combined Crystal Barrel - TAPS detector. The experiment was done at a tagged photon beam of the ELSA electron accelerator in Bonn for incident photon energies from the production threshold up to 2.5 GeV. The $η'$-mesons have been detected in coincidence with recoil protons and recoil neutrons. The quasi-free proton data are in good agreement with the results for free protons, indicating that nuclear effects have no significant impact. The coincidence with recoil neutrons provides the first data for the $γn \rightarrow nη'$ reaction. In addition, also first estimates for coherent $η'$-production off the deuteron have been obtained. In agreement with model predictions, the total cross section for this channel is found to be very small, at most at the level of a few nb. The data are compared to model calculations taking into account contributions from nucleon resonances and $t$-channel exchanges.