Source author record

L. Kuckert

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
4topics
4close collaborators

Published work

2 publications

preprint2016arXiv

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

preprint2016arXiv

Measurement of αα-particle quenching in LAB based scintillator in independent small-scale experiments

The αα-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, αα-particles were produced in the scintillator via 12^{12}C(nn,αα)9^9Be reactions. In the second approach, the scintillator was loaded with 2% of nat^{\mathrm{nat}}Sm providing an αα-emitter, 147^{147}Sm, as an internal source. In the third approach, a scintillator flask was deployed into the water-filled SNO+ detector and the radioactive contaminants 222^{222}Rn, 218^{218}Po and 214^{214}Po provided the αα-particle signal. The behavior of the observed αα-particle light outputs are in agreement with each case successfully described by Birks' law. The resulting Birks parameter kBkB ranges from (0.0066±0.0016)(0.0066\pm0.0016) cm/MeV to (0.0076±0.0003)(0.0076\pm0.0003) cm/MeV. In the first approach, the αα-particle light response was measured simultaneously with the light response of recoil protons produced via neutron-proton elastic scattering. This enabled a first time a direct comparison of kBkB describing the proton and the αα-particle response of LAB based scintillator. The observed kBkB values describing the two light response functions deviate by more than 5σ5σ. The presented results are valuable for all current and future detectors, using LAB based scintillator as target, since they depend on an accurate knowledge of the scintillator response to different particles.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.