Source author record

L. Gallin-Martel

L. Gallin-Martel appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy

In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in order to build TOF spectra of PG generated in a heterogeneous target presenting an air cavity of variable thickness. Since the measurement was carried out at low beam currents ($<$ 1 proton/bunch) it was possible to reach excellent coincidence time resolutions, of the order of 100 ps ($σ$). Our goal is to detect possible deviations of the proton range with respect to treatment planning within a few intense irradiation spots at the beginning of the session and then carry on the treatment at standard beam currents. The measurements were limited to 10 mm proton range shift. A Monte Carlo simulation study reproducing the experiment has shown that a 3 mm shift can be detected at 2$σ$ by a single detector of $\sim 1.4 \times 10^{-3}$ absolute detection efficiency within a single irradiation spot ($\sim$10$^{8}$ protons) and an optimised experimental set-up.

preprint2012arXiv

NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires only two coaxial cables for instrumenting such a large array. The chosen solution and the performances achieved are presented in this paper.

preprint1998arXiv

An Integrated Circuit for Signal Processing of the AMS RICH Photmultipliers Tubes

An analog integrated circuit has been designed, in a BiCMOS 0.8 micron technology, for the feasability study of the signal processing of the AMS RICH photomultiplier tubes. This low power, three channel gated integrator includes its own gate and no external analog delay is requiered. It processes PMT pulses over a dynamic range of more than 100. A logic output that indicates whether the analog charge has to be considered is provided. This gated integrator is used with a compact DSP based acquisition system in a 132 channels RICH prototype. The charge calibration of each channel is carried out using a LED. The pedestal measurement is performed on activation of a dedicated input. The noise contribution study of the input RC network and amplifiers is presented.