Researcher profile

L. Bignell

L. Bignell contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

CLARION2-TRINITY: a Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $γ$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors ($\approx4\%$ efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Finally, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from $^{16}$O + $^{18}$O fusion-evaporation, and PID and Doppler-corrected $γ$-ray spectra from $^{48}$Ti + $^{12}$C Coulomb excitation.

preprint2020arXiv

Improved precision on the experimental E0 decay branching ratio of the Hoyle state

Stellar carbon synthesis occurs exclusively via the $3α$ process, in which three $α$ particles fuse to form $^{12}$C in the excited Hoyle state, followed by electromagnetic decay to the ground state. The Hoyle state is above the $α$ threshold, and the rate of stellar carbon production depends on the radiative width of this state. The radiative width cannot be measured directly, and must instead be deduced by combining three separately measured quantities. One of these quantities is the $E0$ decay branching ratio of the Hoyle state, and the current $10$\% uncertainty on the radiative width stems mainly from the uncertainty on this ratio. The $E0$ branching ratio was deduced from a series of pair conversion measurements of the $E0$ and $E2$ transitions depopulating the $0^+_2$ Hoyle state and $2^+_1$ state in $^{12}$C, respectively. The excited states were populated by the $^{12}$C$(p,p^\prime)$ reaction at 10.5 MeV beam energy, and the pairs were detected with the electron-positron pair spectrometer, Super-e, at the Australian National University. The deduced branching ratio required knowledge of the proton population of the two states, as well as the alignment of the $2^+_1$ state in the reaction. For this purpose, proton scattering and $γ$-ray angular distribution experiments were also performed. An $E0$ branching ratio of $Γ^{E0}_π/Γ=8.2(5)\times10^{-6}$ was deduced in the current work, and an adopted value of $Γ^{E0}_π/Γ=7.6(4)\times10^{-6}$ is recommended based on a weighted average of previous literature values and the new result. The new recommended value for the $E0$ branching ratio is about 14% larger than the previous adopted value of $Γ^{E0}_π/Γ=6.7(6)\times10^{-6}$, while the uncertainty has been reduced from 9% to 5%.