Source author record

Kyung-Han Hong

Kyung-Han Hong appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

Terahertz-driven, all-optical electron gun

Ultrashort electron beams with narrow energy spread, high charge, and low jitter are essential for resolving phase transitions in metals, semiconductors, and molecular crystals. These semirelativistic beams, produced by phototriggered electron guns, are also injected into accelerators for x-ray light sources. The achievable resolution of these time-resolved electron diffraction or x-ray experiments has been hindered by surface field and timing jitter limitations in conventional RF guns, which thus far are <200 MV/m and >96 fs, respectively. A gun driven by optically-generated single-cycle THz pulses provides a practical solution to enable not only GV/m surface fields but also absolute timing stability, since the pulses are generated by the same laser as the phototrigger. Here, we demonstrate an all-optical THz gun yielding peak electron energies approaching 1 keV, accelerated by 300 MV/m THz fields in a novel micron-scale waveguide structure. We also achieve quasimonoenergetic, sub-keV bunches with 32 fC of charge, which can already be used for time-resolved low-energy electron diffraction. Such ultracompact, easy to implement guns driven by intrinsically synchronized THz pulses that are pumped by an amplified arm of the already present photoinjector laser provide a new tool with potential to transform accelerator based science.

preprint2015arXiv

Terahertz-driven linear electron acceleration

The cost, size and availability of electron accelerators is dominated by the achievable accelerating gradient. Conventional high-brightness radio-frequency (RF) accelerating structures operate with 30-50 MeV/m gradients. Electron accelerators driven with optical or infrared sources have demonstrated accelerating gradients orders of magnitude above that achievable with conventional RF structures. However, laser-driven wakefield accelerators require intense femtosecond sources and direct laser-driven accelerators and suffer from low bunch charge, sub-micron tolerances and sub-femtosecond timing requirements due to the short wavelength of operation. Here, we demonstrate the first linear acceleration of electrons with keV energy gain using optically-generated terahertz (THz) pulses. THz-driven accelerating structures enable high-gradient electron or proton accelerators with simple accelerating structures, high repetition rates and significant charge per bunch. Increasing the operational frequency of accelerators into the THz band allows for greatly increased accelerating gradients due to reduced complications with respect to breakdown and pulsed heating. Electric fields in the GV/m range have been achieved in the THz frequency band using all optical methods. With recent advances in the generation of THz pulses via optical rectification of slightly sub-picosecond pulses, in particular improvements in conversion efficiency and multi-cycle pulses, increasing accelerating gradients by two orders of magnitude over conventional linear accelerators (LINACs) has become a possibility. These ultra-compact THz accelerators with extremely short electron bunches hold great potential to have a transformative impact for free electron lasers, future linear particle colliders, ultra-fast electron diffraction, x-ray science, and medical therapy with x-rays and electron beams.

preprint2015arXiv

Toward a terahertz-driven electron gun

Femtosecond electron bunches with keV energies and eV energy spread are needed by condensed matter physicists to resolve state transitions in carbon nanotubes, molecular structures, organic salts, and charge density wave materials. These semirelativistic electron sources are not only of interest for ultrafast electron diffraction, but also for electron energy-loss spectroscopy and as a seed for x-ray FELs. Thus far, the output energy spread (hence pulse duration) of ultrafast electron guns has been limited by the achievable electric field at the surface of the emitter, which is 10 MV/m for DC guns and 200 MV/m for RF guns. A single-cycle THz electron gun provides a unique opportunity to not only achieve GV/m surface electric fields but also with relatively low THz pulse energies, since a single-cycle transform-limited waveform is the most efficient way to achieve intense electric fields. Here, electron bunches of 50 fC from a flat copper photocathode are accelerated from rest to tens of eV by a microjoule THz pulse with peak electric field of 72 MV/m at 1 kHz repetition rate. We show that scaling to the readily-available GV/m THz field regime would translate to monoenergetic electron beams of ~100 keV.

preprint2013arXiv

Recombination Amplitude Calculations of Noble Gases, in Length and Acceleration Forms, beyond Strong Field Approximation

Transition of an electron from a free to a bound state is critical in determining the qualitative shape of the spectrum in high-order harmonic generation (HHG), and in tomographic imaging of orbitals. We calculate and compare the recombination amplitude, from a continuum state described by a plane wave and an outgoing scattering eigenstate, to the bound state for the noble gases that are commonly used in HHG. These calculations are based on the single active electron model and the Hartree-Fock-Slater method, using both the length form and the acceleration form of the dipole matrix element. We confirm that the recombination amplitude versus emitted photon energy strongly depends upon the wavefunction used to describe the free electron. Depending on the choice of the wavefunction and the dipole form, the square of the absolute value of the recombination amplitude can differ by almost two orders of magnitude near the experimentally measured Cooper minima. Moreover, only the outgoing scattering eigenstates with the length form roughly predict the experimentally observed Cooper minimum for Ar (~50 eV) and Kr (~85 eV). We provide a detailed derivation of the photorecombination cross sections (PRCSs) from photo ionization cross sections (PICSs) calculated by the relativistic random phase approximation (RRPA)., For Ar, Kr and Xe, compare the total PICSs calculated using our recombination amplitudes with that obtained from RRPA. We find that PICS calculated using the outgoing scattering eigenstates with the length form is in better agreement with the RRPA calculations than the acceleration form.

preprint2012arXiv

High-order harmonic generation in Xe, Kr, and Ar driven by a 2.1-μm source: high-order harmonic spectroscopy under macroscopic effects

We experimentally and numerically study the atomic response and pulse propagation effects of high-order harmonics generated in Xe, Kr, and Ar driven by a 2.1-μm infrared femtosecond light source. The light source is an optical parametric chirped-pulse amplifier, and a modified strong-field approximation and 3-dimensional pulse propagation code are used for the numerical simulations. The extended cutoff in the long-wavelength driven high-harmonic generation has revealed the spectral shaping of high-order harmonics due to the atomic structure (or photo-recombination cross-section) and the macroscopic effects, which are the main factors of determining the conversion efficiency besides the driving wavelength. Using precise numerical simulations to determine the macroscopic electron wavepacket, we are able to extract the photo-recombination cross-sections from experimental high-order harmonic spectra in the presence of macroscopic effects. We have experimentally observed that the macroscopic effects shift the observed Cooper minimum of Kr from 80 eV to 60-70 eV and wash out the Cooper minimum of Ar. Measured high-harmonic conversion efficiencies per harmonic near the cutoff are ~10^{-9} for all three gases.