Source author record

KyeoReh Lee

KyeoReh Lee appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2026arXiv

Video-rate holographic telepresence via single-shot, reference-free wavefront measurement

We present a reference-free holographic telepresence system that directly captures and replays complex optical wavefronts from a single intensity speckle measurement. Using a pre-characterized geometric phase diffuser, the incident field self-interferes to form a speckle pattern, from which the wavefront is recovered via a speckle-correlation scattering-matrix approach and refined using smoothed amplitude flow with Nesterov acceleration. The reconstructed phase is directly projected onto a spatial light modulator for holographic replay. We demonstrate volumetric refocusing, dynamic three-dimensional reconstruction, and sustained video-rate operation at approximately 28 frames per second with modest communication bandwidth. The results highlight measurement-driven wavefront acquisition as a practical pathway toward compact and physically faithful holographic telepresence.

preprint2021arXiv

3D Fourier transformation light scattering for reconstructing extend angled resolved light scattering of individual particles

We represent three-dimensional Fourier transform light scattering, a method to reconstruct angle-resolved light scattering (ARLS) with extended angle-range from individual spherical objects. To overcome the angle limitation determined by the physical numerical aperture of an optical system, the optical light fields scattered from a sample are measured with various illumination angles, and then synthesized onto the Ewald Sphere corresponding to the normal illumination in Fourier space by rotating the scattered light signals. The method extends the angle range of the ARLS spectra beyond 90 degree, beyond the limit of forward optical measurements. Extended scattered light fields in 3D and corresponding ARLS spectra of individual microscopic polystyrene beads, and protein droplets are represented.

preprint2021arXiv

Enhancing sensitivity in absorption spectroscopy using a scattering cavity

Absorption spectroscopy is widely used to detect samples with spectral specificity. Here, we propose and demonstrate a method for enhancing the sensitivity of absorption spectroscopy. Exploiting multiple light scattering generated by a boron nitride (h-BN) scattering cavity, the optical path lengths of light inside a diffusive reflective cavity are significantly increased, resulting in more than ten times enhancement of sensitivity in absorption spectroscopy. We demonstrate highly sensitive spectral measurements of low concentrations of malachite green and crystal violet aqueous solutions. Because this method only requires the addition of a scattering cavity to existing absorption spectroscopy, it is expected to enable immediate and widespread applications in various fields, from analytical chemistry to environmental sciences.

preprint2020arXiv

Low-coherence optical diffraction tomography using a ferroelectric liquid crystal spatial light modulator

Optical diffraction tomography (ODT) is a three-dimensional (3D) label-free imaging technique. The 3D refractive index distribution of a sample can be reconstructed from multiple two-dimensional optical field images via ODT. Herein, we introduce a temporally low-coherence ODT technique using a ferroelectric liquid crystal spatial light modulator (FLC SLM). The fast binary-phase modulation provided by the FLC SLM ensures a high spatiotemporal resolution with considerably reduced coherent noise. We demonstrate the performance of the proposed system using various samples, including colloidal microspheres and live epithelial cells.

preprint2016arXiv

A simple and rapid method for detecting living microorganisms in food using laser speckle decorrelation

Measuring microorganisms in food products is a critical issue for food safety and human health. Although various approaches for detecting low-levels of microorganisms in food have been developed, they require high-cost, complex equipment, invasive procedures, and skilled technicians which limit their widespread use in the food industry. Here, we present a simple, non-destructive, non-contact, and rapid optical method for measuring living microorganisms in meat products using laser speckle decorrelation. By simply measuring dynamic speckle intensity patterns reflected from samples and analyzing the temporal correlation time, the presence of living microorganisms can be non-invasively detected with high sensitivity. We present proof-of-principle demonstrations for detecting E. coli and B. cereus in chicken breast tissues.

preprint2016arXiv

Collaborative effects of wavefront shaping and optical clearing agent in optical coherence tomography

We demonstrate that simultaneous application of optical clearing agents (OCAs) and complex wavefront shaping in optical coherence tomography (OCT) can provide significant enhancement of the penetration depth and imaging quality. OCA reduces optical inhomogeneity of a highly scattering sample, and the wavefront shaping of illumination light controls multiple scattering, resulting in an enhancement of the penetration depth and signal-to-noise ratio. A tissue phantom study shows that concurrent applications of OCA and wavefront shaping successfully operate in OCT imaging. The penetration depth enhancement is further demonstrated for ex vivo mouse ears, revealing hidden structures inaccessible with conventional OCT imaging.

preprint2016arXiv

Energy-leaky modes in partially measured scattering matrices of disordered media

We investigate energy-leaky modes induced by incomplete measurements of the scattering matrices of complex media. Due to the limited numerical apertures of an optical system, it is experimentally challenging to access theoretically predicted perfect transmission channels in the diffusive regime. By conducting numerical simulations on scattering matrices, we demonstrate that leaky modes contributed from uncollected transmission in the TM provides an energy transmission that is more enhanced than that predicted by measurement. On the other hand, a leaky mode originating from the uncollected reflection in the partial measurement of a RM strongly suppresses the energy transmission through a zero-reflection channel, restricting the transmission enhancement to no more than a 5-fold enhancement in limited optical systems. Our study provides useful insights into the effective control of energy delivery through scattering media and its ultimate limitation in practical schemes.

preprint2016arXiv

Optical characterization of red blood cells from individuals with sickle cell trait and disease in Tanzania using quantitative phase imaging

Sickle cell disease (SCD) is common across Sub-Saharan Africa. However, the investigation of SCD in this area has been significantly limited mainly due to the lack of research facilities and skilled personnel. Here, we present optical measurements of individual red blood cells (RBCs) from healthy individuals and individuals with SCD and sickle cell trait in Tanzania using the quantitative phase imaging technique. By employing a quantitative phase imaging unit (QPIU), an existing microscope in a clinic is transformed into a powerful quantitative phase microscope providing measurements on the morphological, biochemical, and biomechanical properties of individual cells. The present approach will open up new opportunities for cost-effective investigation and diagnosis of several diseases in low resource environments.

preprint2016arXiv

Scattering optical elements: stand-alone optical elements exploiting multiple light scattering

Optical design and fabrication techniques are crucial for making optical elements. From conventional lenses to diffractive optical elements, and to recent metasurfaces, various types of optical elements have been proposed to manipulate light where optical materials are fabricated into desired structures. Here, we propose a scattering optical element (SOE) which exploits multiple light scattering and wavefront shaping. Instead of fabricating optical materials, the SOE consists of a disordered medium and a photopolymer-based wavefront recorder, with shapes the wavefront of impinging light on demand. With the proposed stand-alone SOEs, we experimentally demonstrate control of various properties of light, including intensity, polarisation, spectral frequency and near field. Due to the tremendous freedom brought about by disordered media, the proposed approach will provide unexplored routes to manipulate arbitrary optical fields in stand-alone optical elements.

preprint2016arXiv

Time-reversing a monochromatic subwavelength optical focus by optical phase conjugation of multiply-scattered light

Due to its time-reversal nature, optical phase conjugation generates a monochromatic light wave which retraces its propagation paths. Here, we demonstrate the regeneration of a subwavelength optical focus by phase conjugation. Monochromatic light from a subwavelength source is scattered by random nanoparticles, and the scattered light is phase conjugated at the far-field region by coupling its wavefront into a single-mode optical reflector using a spatial light modulator. Then the conjugated beam retraces its propagation paths and forms a refocus on the source at the subwavelength scale. This is the first direct experimental realization of subwavelength focusing beyond the diffraction limit with far-field time reversal in the optical domain.

preprint2016arXiv

Universal sensitivity of speckle intensity correlations to wavefront change in light diffusers

Here, we present a concept based on the realization that a complex medium can be used as a simple interferometer. Changes in the wavefront of an incident coherent beam can be retrieved by analyzing changes in speckle patterns when the beam passes through a light diffuser. We demonstrate that the spatial intensity correlations of the speckle patterns are independent of the light diffusers, and are solely determined by the phase changes of an incident beam. With numerical simulations using the random matrix theory, and an experimental pressure-driven wavefront-deforming setup using a microfluidic channel, we theoretically and experimentally confirm the universal sensitivity of speckle intensity correlations, which is attributed to the conservation of optical field correlation despite multiple light scattering. This work demonstrates that a complex media is a simple interferometer, and presents opportunities to replace complicated reference-beam-assisted interferometers with a simple and compact scattering layer in various applications in metrology, analytical chemistry, and biomedicine.

preprint2016arXiv

White-light Quantitative Phase Imaging Unit

We introduce the white light quantitative phase imaging unit (WQPIU) as a practical realization of quantitative phase imaging (QPI) on standard microscope platforms. The WQPIU is a compact stand-alone unit which measures sample induced phase delay under white-light illumination. It does not require any modification of the microscope or additional accessories for its use. The principle of the WQPIU based on lateral shearing interferometry and phase shifting interferometry provides a cost-effective and user-friendly use of QPI. The validity and capacity of the presented method are demonstrated by measuring quantitative phase images of polystyrene beads, human red blood cells, HeLa cells and mouse white blood cells. With speckle-free imaging capability due to the use of white-light illumination, the WQPIU is expected to expand the scope of QPI in biological sciences as a powerful but simple imaging tool.

preprint2015arXiv

In vivo deep tissue imaging using wavefront shaping optical coherence tomography

Multiple light scattering in tissue limits the penetration of optical coherence tomography (OCT) imaging. Here, we present in-vivo OCT imaging of a live mouse using wavefront shaping to enhance the penetration depth. A digital micro-mirror device (DMD) was used in a spectral-domain OCT system for complex wavefront shaping of an incident beam which resulted in the optimal delivery of light energy into deep tissue. Ex-vivo imaging of chicken breasts and mouse ear tissues showed enhancements in the strength of the image signals and the penetration depth, and in-vivo imaging of the tail of a live mouse provided a multilayered structure inside the tissue, otherwise invisible in conventional OCT imaging. Signal enhancements by a factor of 3-7 were acquired for various experimental conditions and samples.

preprint2015arXiv

Measurements of complex refractive indices of photoactive yellow protein

A novel optical technique for measuring the complex refractive index (CRI) of photoactive proteins over the wide range of visible wavelengths is presented. Employing quantitative phase microscopy equipped with a wavelength swept source, optical fields transmitted from a solution of photoactive proteins were precisely measured, from which the CRIs of the photoactive proteins were retrieved with the Fourier light scattering technique. Using the present method, both the real and imaginary RIs of a photoactive yellow protein (PYP) solution were precisely measured over a broad wavelength range (461 - 582 nm). The internal population of the ground and excited states were switched by blue light excitation (445 nm center wavelength), and the broadband refractive index increments of each state were measured. The significant CRI deviation between in the presence and absence of the blue excitation was quantified and explained based on the Kramers-Kronig relations.

preprint2015arXiv

Measuring optical transmission matrices by wavefront shaping

We introduce a simple but practical method to measure the optical transmission matrix (TM) of complex media. The optical TM of a complex medium is obtained by modulating the wavefront of a beam impinging on the complex medium and imaging the transmitted full-field speckle intensity patterns. Using the retrieved TM, we demonstrate the generation and linear combination of multiple foci on demand through the complex medium. This method will be used as a versatile tool for coherence control of waves through turbid media.

preprint2015arXiv

One-wave optical phase conjugation mirror by actively coupling arbitrary light fields into a single-mode reflector

Rewinding the arrow of time via phase conjugation is an intriguing phenomena made possible by the wave property of light. To exploit this phenomenon, diverse research fields have pursed the realization of an ideal phase conjugation mirror, but an optical system that requires a single-input and a single-output beam, like natural conventional mirrors has never been demonstrated. Here, we demonstrate the realization of a one-wave optical phase conjugation mirror using a spatial light modulator. An adaptable single-mode filter is created, and a phase-conjugate beam is then prepared by reverse propagation through this filter. Our method is simple, alignment free, and fast while allowing high power throughput in the time reversed wave, which have not been simultaneously demonstrated before. Using our method, we demonstrate high throughput full-field light delivery through highly scattering biological tissue and multimode fibers, even for quantum dot fluorescence.

preprint2015arXiv

Optogenetic control of cell signaling pathway through scattering skull using wavefront shaping

We introduce a non-invasive approach for optogenetic regulation in biological cells through highly scattering skull tissue using wavefront shaping. The wavefront of the incident light was systematically controlled using a spatial light modulator in order to overcome multiple light-scattering in a mouse skull layer and to focus light on the target cells. We demonstrate that illumination with shaped waves enables spatiotemporal regulation of intracellular Ca2+ level at the individual-cell level.