Source author record

Kwang-Je Kim

Kwang-Je Kim appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2019arXiv

Statistical properties of undulator radiation in the IOTA storage ring

We study turn-by-turn fluctuations in the number of spontaneously emitted photons from an undulator, installed in the Integrable Optics Test Accelerator (IOTA) electron storage ring at Fermilab. A theoretical model is presented, showing the relative contributions due to the discrete nature of light emission and to the incoherent sum of fields from different electrons in the bunch. The model is compared with a previous experiment at Brookhaven and with new experiments we carried out at IOTA. Our experiments focused on the case of a large number of longitudinal and transverse radiation modes, a regime where photon shot noise is significant and the total magnitude of the fluctuations is very small. The experimental and data analysis techniques, required to reach the desired sensitivity, are detailed. We discuss how the model and the experiment provide insights into this emission regime, enable diagnostics of small beam sizes, and improve our understanding of beam lifetime in IOTA.

preprint2010arXiv

Nanoradian angular stabilization of x-ray optical components

An x-ray free electron laser oscillator (XFELO) has been recently proposed [K. Kim, Y. Shvyd'ko, and S. Reiche, Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko Phys. Rev. STAB 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high energy resolution x-ray monochromator ($ΔE/E \simeq 4 \times 10^{-8}$, $E$ = 23.7 keV) and a high heat load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.