Researcher profile

Konrad Altenmüller

Konrad Altenmüller contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination

Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one of the most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with a segmented Micromegas, for the direct measurement of $^{210}$Pb surface contamination of flat samples. The detection concept exploits the readout capabilities of the Micromegas detectors for the reconstruction of $^{210}$Po alpha tracks to increase the signal-to-background ratio. We report here on the design and realization of a first 26$\times$26 cm$^2$ non-radiopure prototype, with which the detection concept is demonstrated by the use of a new algorithm for the reconstruction of alpha tracks. AlphaCAMM aims for minimum detectable $^{210}$Pb activities of $100$ nBq cm$^{-2}$ and sensitivity upper limits about $60$ nBq cm$^{-2}$ at 95\% of C.L., which requires an intrinsic background level of $5\times10^{-8}$ alphas cm$^{-2}$ s$^{-1}$. We discuss here the prospects to reach these sensitivity goals with a radiopure AlphaCAMM prototype currently under construction.

preprint2021arXiv

REST-for-Physics, a ROOT-based framework for event oriented data analysis and combined Monte Carlo response

The REST-for-Physics (Rare Event Searches Toolkit for Physics) framework is a ROOT-based solution providing the means to process and analyze experimental or Monte Carlo event data. Special care has been taken on the traceability of the code and the validation of the results produced within the framework, together with the connectivity between code and data stored registered through specific version metadata members. The framework development was originally motivated to cover the needs at Rare Event Searches experiments (experiments looking for phenomena having extremely low occurrence probability like dark matter or neutrino interactions or rare nuclear decays), and its components naturally implement tools to address the challenges in these kinds of experiments; the integration of a detector physics response, the implementation of signal processing routines, or topological algorithms for physical event identification are some examples. Despite this specialization, the framework was conceived thinking in scalability, and other event-oriented applications could benefit from the data processing routines and/or metadata description implemented in REST, being the generic framework tools completely decoupled from dedicated libraries. REST-for-Physics is a consolidated piece of software already serving the needs of different physics experiments - using gaseous Time Projection Chambers (TPCs) as detection technology - for background data analysis and detector characterization, as well as generic detector R\&D. Even though REST has been exploited mainly with gaseous TPCs, the code could be easily applied or adapted to other detection technologies. We present in this work an overview of REST-for-Physics, providing a broad perspective to the infrastructure and organization of the project as a whole. The framework and its different components will be described in the text.

preprint2020arXiv

Hunting keV sterile neutrinos with KATRIN: building the first TRISTAN module

The KATRIN (Karlsruhe Tritium Neutrino) experiment investigates the energetic endpoint of the tritium beta-decay spectrum to determine the effective mass of the electron anti-neutrino. The collaboration has reported a first mass measurement result at this TAUP-2019 conference. The TRISTAN project aims at detecting a keV-sterile neutrino signature by measuring the entire tritium beta-decay spectrum with an upgraded KATRIN system. One of the greatest challenges is to handle the high signal rates generated by the strong activity of the KATRIN tritium source while maintaining a good energy resolution. Therefore, a novel multi-pixel silicon drift detector and read-out system are being designed to handle rates of about 100 Mcps with an energy resolution better than 300 eV (FWHM). This report presents succinctly the KATRIN experiment, the TRISTAN project, then the results of the first 7-pixels prototype measurement campaign and finally describes the construction of the first TRISTAN module composed of 166 SDD-pixels as well as its implementation in KATRIN experiment.

preprint2019arXiv

Measurements with a TRISTAN prototype detector system at the "Troitsk nu-mass" experiment in integral and differential mode

Sterile neutrinos emerge in minimal extensions of the Standard Model which can solve a number of open questions in astroparticle physics. For example, sterile neutrinos in the keV-mass range are viable dark matter candidates. Their existence would lead to a kink-like distortion in the tritium $β$-decay spectrum. In this work we report about the instrumentation of the Troitsk nu-mass experiment with a 7-pixel TRISTAN prototype detector and measurements in both differential and integral mode. The combination of the two modes is a key requirement for a precise sterile neutrino search, as both methods are prone to largely different systematic uncertainties. Thanks to the excellent performance of the TRISTAN detector at high rates, a sterile neutrino search up to masses of about 6 keV could be performed, which enlarges the previous accessible mass range by a factor of 3. Upper limits on the neutrino mixing amplitude in the mass range < 5.6 keV (differential) and < 6.6 keV (integral) are presented. These results demonstrate the feasibility of a sterile neutrino search as planned in the upgrade of the KATRIN experiment with the final TRISTAN detector and read-out system.