Source author record

Kevin Welsher

Kevin Welsher appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2019arXiv

Continuous focal translation enhances rate of point-scan volumetric microscopy

Two-Photon Laser-Scanning Microscopy is a powerful tool for exploring biological structure and function because of its ability to optically section through a sample with a tight focus. While it is possible to obtain 3D image stacks by moving a stage, this perframe imaging process is time consuming. Here, we present a method for an easy to implement and inexpensive modification of an existing two-photon microscope to rapidly image in 3D using an electrically tunable lens to create a tessellating scan pattern which repeats with the volume rate. Using appropriate interpolating algorithms, the volumetric imaging rate can be increased by a factor up to four-fold. This capability provides the expansion of the two-photon microscope into the third dimension for faster volumetric imaging capable of visualizing dynamics on timescales not achievable by traditional stage stack methods.

preprint2011arXiv

Deep-Tissue Anatomical Imaging of Mice Using Carbon Nanotube Fluorophores in the Second Near Infrared Window

Fluorescent imaging in the second near infrared window (NIR II, 1-1.4 μm) holds much promise due to minimal autofluorescence and tissue scattering. Here, using well functionalized biocompatible single-walled carbon nanotubes (SWNTs) as NIR II fluorescent imaging agents, we performed high frame rate video imaging of mice during intravenous injection of SWNTs and investigated the path of SWNTs through the mouse anatomy. We observed in real-time SWNT circulation through the lungs and kidneys several seconds post-injection, and spleen and liver at slightly later time points. Dynamic contrast enhanced imaging through principal component analysis (PCA) was performed and found to greatly increase the anatomical resolution of organs as a function of time post-injection. Importantly, PCA was able to discriminate organs such as the pancreas which could not be resolved from real-time raw images. Tissue phantom studies were performed to compare imaging in the NIR II region to the traditional NIR I biological transparency window (700- 900 nm). Examination of the feature sizes of a common NIR I dye (indocyanine green, ICG) showed a more rapid loss of feature contrast and integrity with increasing feature depth as compared to SWNTs in the NIR II region. The effects of increased scattering in the NIR I versus NIR II region were confirmed by Monte Carlo simulation. In vivo fluorescence imaging in the NIR II region combined with PCA analysis may represent a powerful approach to high resolution optical imaging through deep tissues, useful for a wide range of applications from biomedical research to disease diagnostics.

preprint2011arXiv

Near-Infrared Fluorescence Enhanced (NIR-FE) Molecular Imaging of Live Cells on Gold Substrates

Low quantum yields of near infrared (NIR) fluorophores have limited their capabilities as imaging probes in a transparent, low background imaging window. Here for the first time we reported near-infrared fluorescence enhance (NIR-FE) cell imaging using nanostructured Au substrate, which was employed as a general platform for both single-walled carbon nanotubes (SWNTs) and organic fluorescent labels in the NIR region. Fluorescence intensity, as well as cell targeting specificity, was greatly improved by this novel imaging technique. With NIR-FE imaging, we were able to image SWNT-stained cells at short exposure time of 300ms, and push the detectable limit of SWNT staining of cells down to an ultralow concentration of ~50 pM. Further, different degrees of fluorescence enhancement for endocytosed, intracellular SWNTs vs. nanotubes on the cell membrane at the cell/gold interface were observed, suggesting the possibility of using this technique to track the transmembrane behavior of NIR fluorophores.

preprint2010arXiv

High Performance In Vivo Near-IR (>1 μm) Imaging and Photothermal Cancer Therapy with Carbon Nanotubes

Short single-walled carbon nanotubes (SWNTs) functionalized by PEGylated phospholipids are biologically non-toxic and long-circulating nanomaterials with intrinsic near infrared photoluminescence (NIR PL), characteristic Raman spectra, and strong optical absorbance in the near infrared (NIR). This work demonstrates the first dual application of intravenously injected SWNTs as photoluminescent agents for in vivo tumor imaging in the 1.0-1.4 μm emission region and as NIR absorbers and heaters at 808 nm for photothermal tumor elimination at the lowest injected dose (70 μg of SWNT/mouse, equivalent to 3.6 mg/kg) and laser irradiation power (0.6 W/cm2) reported to date. Ex vivo resonance Raman imaging revealed the SWNT distribution within tumors at a high spatial resolution. Complete tumor elimination was achieved for large numbers of photothermally treated mice without any toxic side effects after more than six months post-treatment. Further, side-by-side experiments were carried out to compare the performance of SWNTs and gold nanorods (AuNRs) at an injected dose of 700 μg of AuNR/mouse (equivalent to 35 mg/kg) in NIR photothermal ablation of tumors in vivo. Highly effective tumor elimination with SWNTs was achieved at 10 times lower injected doses and lower irradiation powers than for AuNRs. These results suggest there are significant benefits of utilizing the intrinsic properties of biocompatible SWNTs for combined cancer imaging and therapy.

preprint2010arXiv

Metal-Enhanced Fluorescence of Carbon Nanotubes

The photoluminescence (PL) quantum yield of single-walled carbon nanotubes (SWNTs) is relatively low, with various quenching effects by metallic species reported in the literature. Here, we report the first case of metal enhanced fluorescence (MEF) of surfactant-coated carbon nanotubes on nanostructured gold substrates. The photoluminescence quantum yield of SWNTs is observed to be enhanced more than 10-fold. The dependence of fluorescence enhancement on metal-nanotube distance and on surface plasmon resonance (SPR) of the gold substrate for various SWNT chiralities is measured to reveal the mechanism of enhancement. Surfactant-coated SWNTs in direct contact with metal exhibit strong MEF without quenching, suggesting a small quenching distance for SWNTs on the order of the van der Waals distance, beyond which the intrinsically fast non-radiative decay rate in nanotubes is little enhanced by metal. The metal enhanced fluorescence of SWNTs is attributed to radiative lifetime shortening through resonance coupling of SWNT emission to the re-radiating dipolar plasmonic modes in the metal.