Source author record

Kentaro Uesugi

Kentaro Uesugi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Full field X-ray Scatter Tomography

In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.

preprint2020arXiv

Structural diverseness of neurons between brain areas and between cases

The cerebral cortex is composed of multiple cortical areas that exert a wide variety of brain functions. Although human brain neurons are genetically and areally mosaic, the three-dimensional structural differences between neurons in different brain areas or between the neurons of different individuals have not been delineated. Here, we report a nanometer-scale geometric analysis of brain tissues of the superior temporal gyrus of 4 schizophrenia and 4 control cases by using synchrotron radiation nanotomography. The results of the analysis and a comparison with results for the anterior cingulate cortex indicated that 1) neuron structures are dissimilar between brain areas and that 2) the dissimilarity varies from case to case. The structural diverseness was mainly observed in terms of the neurite curvature that inversely correlates with the diameters of the neurites and spines. The analysis also revealed the geometric differences between the neurons of the schizophrenia and control cases, suggesting that neuron structure is associated with brain function. The area dependency of the neuron structure and its diverseness between individuals should represent the individuality of brain functions.

preprint2016arXiv

A method for estimating spatial resolution of real image in the Fourier domain

Spatial resolution is a fundamental parameter in structural sciences. In crystallography, the resolution is determined from the detection limit of high-angle diffraction in reciprocal space. In electron microscopy, correlation in the Fourier domain is used for estimating the resolution. In this paper, we report a method for estimating the spatial resolution of real images from a logarithmic intensity plot in the Fourier domain. The logarithmic intensity plots of test images indicated that the full width at half maximum of a Gaussian point-spread function can be estimated from the images. The spatial resolution of imaging X-ray microtomography using Fresnel zone-plate optics was also estimated with this method. A cross section of a test object visualized with the imaging microtomography indicated that square-wave patterns up to 120-nm pitch were resolved. The logarithmic intensity plot was calculated from a tomographic cross section of brain tissue. The full width at half maximum of the point spread function estimated from the plot coincided with the resolution determined from the test object. These results indicated that the logarithmic intensity plot in the Fourier domain provides an alternative measure of the spatial resolution without explicitly defining a noise criterion.

preprint2016arXiv

Estimation of presampling modulation transfer function in synchrotron radiation microtomography

The spatial resolution achieved by recent synchrotron radiation microtomographs should be estimated from the modulation transfer function (MTF) on the micrometer scale. Step response functions of a synchrotron radiation microtomograph were determined by the slanted edge method by using high-precision surfaces of diamond crystal and ion-milled aluminum wire. Tilted reconstruction was introduced to enable any edge to be used as the slanted edge by defining the reconstruction pixel matrix in an arbitrary orientation. MTFs were estimated from the step response functions of the slanted edges. The obtained MTFs coincided with MTF values estimated from square-wave patterns milled on the aluminum surface. Although x-ray refraction influences should be taken into account to evaluate MTFs, any flat surfaces with nanometer roughness can be used to determine the spatial resolutions of microtomographs.

preprint2016arXiv

Submicrometer tomographic resolution examined using a micro-fabricated test object

To estimate the spatial resolution of microtomographs, a test object on the submicrometer scale was prepared by focused ion beam milling and subjected to microtomographic analysis. Since human tissues are composed of cells and extracellular matrices with micrometer and submicrometer structures, it is important to investigate the three-dimensional spatial resolution of microtomographs used to visualize microstructures of human tissues. The resolutions along the direction within the tomographic slice plane (in-plane resolution) and perpendicular to it (through-plane resolution) were determined from the modulation transfer function of square-wave patterns. The in-plane resolution was estimated to be 1.2 um from the modulation transfer function of the non-zoom image. In contrast, the zoom image gave the in-plane resolution of 0.8 um. This in-plane resolution is comparable to the through-plane resolution, which was estimated to be 0.8 um. Although the two-dimensional radiographs were taken with the pixel width of half the x-ray optics resolution, these three-dimensional resolution analyses indicated that the zoom reconstruction should be performed to achieve the in-plane resolution comparable to the x-ray optics resolution. The submicrometer three-dimensional analysis was applied in the structural study of human cerebral tissue stained with high-Z elements and the obtained tomograms revealed that the microtomographic analysis allows visualization of the subcellular structures of the cerebral tissue.

preprint2016arXiv

Three-dimensional microtomographic imaging of human brain cortex

This paper describes an x-ray microtomographic technique for imaging the three-dimensional structure of the human cerebral cortex. Neurons in the brain constitute a neural circuit as a three-dimensional network. The brain tissue is composed of light elements that give little contrast in a hard x-ray transmission image. The contrast was enhanced by staining neural cells with metal compounds. The obtained structure revealed the microarchitecture of the gray and white matter regions of the frontal cortex, which is responsible for the higher brain functions.

preprint2016arXiv

Three-dimensional network of Drosophila brain hemisphere

The first step to understanding brain function is to determine the brain's network structure. We report a three-dimensional analysis of the brain network of the fruit fly Drosophila melanogaster by synchrotron-radiation tomographic microscopy. A skeletonized wire model of the left half of the brain network was built by tracing the three-dimensional distribution of X-ray absorption coefficients. The obtained models of neuronal processes were classified into groups on the basis of their three-dimensional structures. These classified groups correspond to neuronal tracts that send long-range projections or repeated structures of the optic lobe. The skeletonized model is also composed of neuronal processes that could not be classified into the groups. The distribution of these unclassified structures correlates with the distribution of contacts between neuronal processes. This suggests that neurons that cannot be classified into typical structures should play important roles in brain functions. The quantitative description of the brain network provides a basis for structural and statistical analyses of the Drosophila brain. The challenge is to establish a methodology for reconstructing the brain network in a higher-resolution image, leading to a comprehensive understanding of the brain structure.

preprint2016arXiv

X-ray microtomographic visualization of Escherichia coli by metalloprotein overexpression

This paper reports X-ray microtomographic visualization of the microorganism Escherichia coli overexpressing a metalloprotein ferritin. The three-dimensional distribution of linear absorption coefficients determined using a synchrotron radiation microtomograph with a simple projection geometry revealed that the X-ray absorption was homogeneously distributed, suggesting that every E. coli cell was labeled with the ferritin. The ferritin-expressing E. coli exhibited linear absorption coefficients comparable to those of phosphotungstic-acid stained cells. The submicrometer structure of the ferritin-expressing E. coli cells was visualized by Zernike phase contrast using an imaging microtomograph equipped with a Fresnel zone plate. The obtained images revealed curved columnar or bunching oval structures corresponding to the E. coli cells. These results indicate that the metalloprotein overexpression facilitates X-ray visualization of three-dimensional cellular structures of biological objects.