Researcher profile

Keith Gendreau

Keith Gendreau contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Discovery and Long-term Broadband X-ray monitoring of Galactic Black Hole Candidate MAXI J1803-298

We report the results from the broad-band X-ray monitoring of the new Galactic black hole candidate MAXI J1803$-$298 with the MAXI/GSC and Swift/BAT during its outburst. After the discovery on 2021 May 1, the soft X-ray flux below 10 keV rapidly increased for $\sim 10$ days and then have been gradually decreasing over 5 months. At the brightest phase, the source exhibited the state transition from the low/hard state to the high/soft state via the intermediate state. The broad-band X-ray spectrum during the outburst was well described with a disk blackbody plus its thermal or non-thermal Comptonization. Before the transition the source spectrum was described by a thermal Comptonization component with a photon index of $\sim 1.7$ and an electron temperature of $\sim 30$ keV, whereas a strong disk blackbody component was observed after the transition. The spectral properties in these periods are consistent with the low/hard state and the high/soft state, respectively. A sudden flux drop with a few days duration, unassociated with a significant change in the hardness ratio, was found in the intermediate state. A possible cause of this variation is that the mass accretion rate rapidly increased at the disk transition, which induced a strong Compton-thick outflow and scattered out the X-ray flux. Assuming a non-spinning black hole, we estimated a black hole mass of MAXI J1803$-$298 as $5.8 \pm 0.4~(\cos i/\cos 70^\circ)^{-1/2} (D/8~\mathrm{kpc})~M_\odot$ (where $i$ and $D$ are the inclination angle and the distance) from the inner disk radius obtained in the high/soft state.

preprint2022arXiv

NICER X-ray Observations of Eta Carinae During its Most Recent Periastron Passage

We report high-precision X-ray monitoring observations in the 0.4-10 keV band of the luminous, long-period colliding-wind binary Eta Carinae up to and through its most recent X-ray minimum/periastron passage in February 2020. Eta Carinae reached its observed maximum X-ray flux on 7 January 2020, at a flux level of $3.30 \times 10^{-10}$ ergs s$^{-1}$ cm$^{-2}$, followed by a rapid plunge to its observed minimum flux, $0.03 \times 10^{-10}$ ergs s$^{-1}$ cm$^{-2}$ near 17 February 2020. The NICER observations show an X-ray recovery from minimum of only $\sim$16 days, the shortest X-ray minimum observed so far. We provide new constraints of the "deep" and "shallow" minimum intervals. Variations in the characteristic X-ray temperature of the hottest observed X-ray emission indicate that the apex of the wind-wind "bow shock" enters the companion's wind acceleration zone about 81 days before the start of the X-ray minimum. There is a step-like increase in column density just before the X-ray minimum, probably associated with the presence of dense clumps near the shock apex. During recovery and after, the column density shows a smooth decline, which agrees with previous $N_{H}$ measurements made by SWIFT at the same orbital phase, indicating that changes in mass-loss rate are only a few percent over the two cycles. Finally, we use the variations in the X-ray flux of the outer ejecta seen by NICER to derive a kinetic X-ray luminosity of the ejecta of $\sim 10^{41}$ ergs s$^{-1}$ near the time of the "Great Eruption'.

preprint2020arXiv

A NICER View of Spectral and Profile Evolution for Three X-ray Emitting Millisecond Pulsars

We present two years of Neutron star Interior Composition Explorer (NICER) X-ray observations of three energetic rotation-powered millisecond pulsars (MSPs): PSRs B1937+21, B1821-24, and J0218+4232. We fit Gaussians and Lorentzians to the pulse profiles for different energy sub-bands of the soft X-ray regime to measure the energy dependence of pulse separation and width. We find that the separation between pulse components of PSR J0218+4232 decreases with increasing energy at $\gt 3σ$ confidence. The 95% upper limit on pulse separation evolution for PSRs B1937+21 and B1821-24 is less than 2 milliperiods per keV. Our phase-resolved spectral results provide updated constraints on the non-thermal X-ray emission of these three pulsars. The photon indices of the modeled X-ray emission spectra for each pulse component of PSR B1937+21 are inconsistent with each other at the 90% confidence level, suggesting different emission origins for each pulse. We find that the PSR B1821-24 and PSR J0218+4232 emission spectra are invariant with phase at the 90% confidence level. We describe the implications of our profile and spectral results in the context of equatorial current sheet emission models for these three MSPs with non-thermal, magnetospheric X-ray emission.

preprint2020arXiv

Phase Fresnel Lens Development for X-ray and Gamma-ray Astronomy

In principle, diffractive optics, particularly Phase Fresnel Lenses (PFLs), offer the ability to construct large, diffraction-limited, and highly efficient X-ray/$γ$-ray telescopes, leading to dramatic improvement in angular resolution and photon flux sensitivity. As the diffraction limit improves with increasing photon energy, gamma-ray astronomy would offer the best angular resolution over the entire electromagnetic spectrum. A major improvement in source sensitivity would be achieved if meter-size PFLs can be constructed, as the entire area of these optics focuses photons. We have fabricated small, prototype PFLs using Micro-Electro-Mechanical Systems (MEMS) fabrication techniques at the University of Maryland and measured near diffraction-limited performance with high efficiency using 8 keV and higher energy X-rays at the GSFC 600-meter Interferometry Testbed. A first generation, 8 keV PFL has demonstrated imaging corresponding to an angular resolution of approximately 20 milli-arcseconds with an efficiency $\sim$70$\%$ of the theoretical expectation. The results demonstrate the superior imaging potential in the X-ray/$γ$-ray energy band for PFL-based optics in a format that is scalable for astronomical instrumentation. Based upon this PFL development, we have also fabricated a `proof-of-principle' refractive-diffractive achromat and initial measurements have demonstrated nearly uniform imaging performance over a large energy range. These results indicate that the chromaticity inherent in diffractive optics can be alleviated.