Source author record

Ke Yue

Ke Yue appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Accelerating Laue Depth Reconstruction Algorithm with CUDA

The Laue diffraction microscopy experiment uses the polychromatic Laue micro-diffraction technique to examine the structure of materials with sub-micron spatial resolution in all three dimensions. During this experiment, local crystallographic orientations, orientation gradients and strains are measured as properties which will be recorded in HDF5 image format. The recorded images will be processed with a depth reconstruction algorithm for future data analysis. But the current depth reconstruction algorithm consumes considerable processing time and might take up to 2 weeks for reconstructing data collected from one single experiment. To improve the depth reconstruction computation speed, we propose a scalable GPU program solution on the depth reconstruction problem in this paper. The test result shows that the running time would be 10 to 20 times faster than the prior CPU design for various size of input data.

preprint2022arXiv

Ptychopy: GPU framework for ptychographic data analysis

X-ray ptychography imaging at synchrotron facilities like the Advanced Photon Source (APS) involves controlling instrument hardwares to collect a set of diffraction patterns from overlapping coherent illumination spots on extended samples, managing data storage, reconstructing ptychographic images from acquired diffraction patterns, and providing the visualization of results and feedback. In addition to the complicated workflow, ptychography instrument could produce up to several TB's of data per second that is needed to be processed in real time. This brings up the need to develop a high performance, robust and user friendly processing software package for ptychographic data analysis. In this paper we present a software framework which provides functionality of visualization, work flow control, and data reconstruction. To accelerate the computation and large datasets process, the data reconstruction part is implemented with three algorithms, ePIE, DM and LSQML using CUDA-C on GPU.

preprint2016arXiv

Temperature dependence of the plastic scintillator detector for DAMPE

The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -$10$ to $30^{\circ}$C, so the temperature effect of the whole detection system should be studied in detail. The temperature dependence of the PSD system is mainly contributed by the three parts: the plastic scintillator bar, the photomultiplier tube (PMT), and the Front End Electronics (FEE). These three parts have been studied in detail and the contribution of each part has been obtained and discussed. The temperature coefficient of the PMT is $-0.320(\pm0.033)\%/^{\circ}$C, and the coefficient of the plastic scintillator bar is $-0.036(\pm0.038)\%/^{\circ}$C. This result means that after subtracting the FEE pedestal, the variation of the signal amplitude of the PMT-scintillator system due to temperature mainly comes from the PMT, and the plastic scintillator bar is not sensitive to temperature over the operating range. Since the temperature effect cannot be ignored, the temperature dependence of the whole PSD has been also studied and a correction has been made to minimize this effect. The correction result shows that the effect of temperature on the signal amplitude of the PSD system can be suppressed.

preprint2015arXiv

A large area plastic scintillation detector with 4-corner-readout

A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $γ$ rays. A position-independent effective time T$_{eff}$ has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from four corners. A TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.