Researcher profile

Kayla M. Rossi

Kayla M. Rossi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

CCAT-prime: Design of the Mod-Cam receiver and 280 GHz MKID instrument module

Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater mapping speed than current and near-term facilities for unprecedented 280-850 GHz broadband and spectroscopic measurements with microwave kinetic inductance detectors (MKIDs). CCAT-prime will address a suite of science goals, from Big Bang cosmology to star formation and galaxy evolution over cosmic time. Mod-Cam deployment on FYST with a 280 GHz instrument module containing MKID arrays is planned for early science observations in 2024. Mod-Cam will be used to test instrument modules for Prime-Cam, which can house up to seven instrument modules. We discuss the design and status of the 0.9 m diameter, 1.8 m long Mod-Cam receiver and 40 cm diameter 280 GHz instrument module, with cold stages at 40 K, 4 K, 1 K, and 100 mK. We also describe the instrument module's cryogenic readout designs to enable the readout of more than 10,000 MKIDs across 18 networks.

preprint2022arXiv

CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam

Prime-Cam is a first-generation instrument for the Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) Facility. The 850$~$GHz module for Prime-Cam will probe the highest frequency of all the instrument modules. We describe the parameter space of the 850$~$GHz optical system between the F$λ$ spacing, beam size, pixel sensitivity, and detector count. We present the optimization of an optical design for the 850$~$GHz instrument module for CCAT-prime. We further describe the development of the cryogenic RF chain design to accommodate $>$30 readout lines to read 41,400 kinetic inductance detectors (KIDs) within the cryogenic testbed.

preprint2022arXiv

CCAT-prime: RFSoC Based Readout for Frequency Multiplexed Kinetic Inductance Detectors

The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every category of size, weight, power, cost, and bandwidth over the previous generation readout systems. We describe a baseline firmware design which can read out four independent RF networks each with 500 MHz of bandwidth and 1000 detectors for ~30 W. The overall readout architecture is a combination of hardware, gateware/firmware, software, and network design. The requirements of the readout are driven by the 850 GHz instrument module of the 7-module Prime-Cam instrument. These requirements along with other constraints which have led to critical design choices are highlighted. Preliminary measurements of the system phase noise and dynamic range are presented.

preprint2022arXiv

CCAT-prime: The 850 GHz camera for Prime-Cam on FYST

The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity mapping during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be the highest frequency module in Prime-Cam and the most novel for astronomical and cosmological surveys, taking full advantage of the atmospheric transparency at the high 5600 meter CCAT-prime siting on Cerro Chajnantor. With a 1.1 deg diameter field, the 850 GHz module will deploy ~40,000 Kinetic Inductance Detectors (KIDs) with Silicon platelet feedhorn coupling (both fabricated at NIST), and will provide unprecedented broadband intensity and polarization measurement capabilities. The 850 GHz module will be key to addressing pressing astrophysical questions regarding galaxy formation, Big Bang cosmology, and star formation within our own Galaxy. We present the motivation and overall design for the module, and initial laboratory characterization.

preprint2022arXiv

CCAT-prime: The Design and Characterization of the Silicon Mirrors for the Fabry-Perot Interferometer in the Epoch of Reionization Spectrometer

The Epoch of Reionization Spectrometer (EoR-Spec) is one of the instrument modules to be installed in the Prime-Cam receiver of the Fred Young Submillimeter Telescope (FYST). This six-meter aperture telescope will be built on Cerro Chajnantor in the Atacama Desert in Chile. EoR-Spec is designed to probe early star-forming regions by measuring the [CII] fine-structure lines between redshift z = 3.5 and z = 8 using the line intensity mapping technique. The module is equipped with a scanning Fabry-Perot interferometer (FPI) to achieve the spectral resolving power of about RP = 100. The FPI consists of two parallel and identical, highly reflective mirrors with a clear aperture of 14 cm, forming a resonating cavity called etalon. The mirrors are silicon-based and patterned with double-layer metamaterial anti-reflection coatings (ARC) on one side and metal mesh reflectors on the other. The double-layer ARCs ensure a low reflectance at one substrate surface and help tailor the reflectance profile over the FPI bandwidth. Here we present the design, fabrication processes, test setup, and characterization of silicon mirrors for the FPI.