Source author record

K. Shimomura

K. Shimomura appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC

The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.

preprint2021arXiv

New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam

A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of $ν_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.

preprint2020arXiv

Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam

A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $μ$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.

preprint2020arXiv

Study of muonium emission from laser-ablated silica aerogel

The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some extreme conditions. The measured emission rate tends to be higher for larger fractions of ablation opening and for shallower depths. More than a few ablation structures reach the emission rates similar to the highest achieved in the past measurements. The emission rate is found to be stable at least for a couple of days. Measurements of spin precession amplitudes for the produced muonium atoms and remaining muons in a magnetic field determine a muonium formation fraction of $(65.5 \pm 1.8)$%. The precession of the polarized muonium atoms is also observed clearly in vacuum. A projection of the emission rates measured at TRIUMF to the corresponding rates at J-PARC is demonstrated taking the different beam condition into account reasonably.

preprint2015arXiv

Electronic structure of shallow donor state associated with muonium in rutile TiO$_2$

The hyperfine structure of the interstitial muonium (Mu) center in rutile (TiO$_2$, weakly $n$-type) has been identified by means of muon spin rotation technique. The angle-resolved hyperfine parameter has a tetragonal anisotropy within the $ab$ plane and axial anisotropy along the $c$ axis, strongly suggesting that Mu simulates the known local structure of interstitial hydrogen (H) located at an off-center position within a channel along $c$ axis, and the electron wave function bound to Mu is highly delocalized (~1.5 nm along $c$ axis, ~0.8 nm for $a$ axis). The ionization energy of Mu ($\rightarrow μ^+ + e^-$) due to thermal activation is deduced to be 1.2(4) meV, as is directly inferred from the disappearance of Mu signal above ~8 K. These observations suggest that electronic level associated with Mu (as well as H) is situated near the bottom of the conduction band, serving as a shallow donor state in rutile.

preprint2014arXiv

Enhancement of muonium emission rate from silica aerogel with a laser ablated surface

Emission of muonium ($μ^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~μ$m in a triangular pattern with hole separation in the range of 300--500$~μ$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.

preprint2013arXiv

Measurement of muonium emission from silica aerogel

Emission of muonium ($μ^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expected from a diffusion process, while small deviations from a simple room-temperature thermal diffusion model are identified. The parameters of the diffusion process are deduced from the observed yields.

preprint2011arXiv

J-PARC MUSE H-line optimization for the g-2 and MuHFS experiments

Significant deviation of the anomalous magnetic moment value (g-2) observed by the muon g-2 experiment should be confirmed by the other experiment. This value is experimentally determined by frequency difference observed by the g-2/EDM experiment and muon magnetic moment observed by the muonium hyperfine splitting experiment (MuHFS). Both two experiments are planned to be performed at H-line of the J-PARC/MUSE under construction. We optimized the beamline layout for each experiment with G4beamline. For both experiments, statistics is the most important, thus beamline transmission efficiency should be maximized. Especially for the g-2, the purpose of the present effort is to compromise between small beam size and small leakage field. For the MuHFS, it is crucial to minimize leakage field at around final focus position, and to get all stopped muons within good field region of MuHFS magnet. Conceptual design of the several final focusing systems will be presented. contribution (or invited paper) to NUFACT 11, XIIIth International Workshop on Neutrino Factories, Super beams and Beta beams, 1-6 August 2011, CERN and University of Geneva