Source author record

K. Schloesser

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
4topics
4close collaborators

Published work

2 publications

preprint2020arXiv

Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN

We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass m4m_{4}. The analysis is sensitive to a fourth mass state m42≲m^2_{4} \lesssim 1000 eV2^2 and to active-to-sterile neutrino mixing down to ∣Ue4∣2≳2⋅10−2|U_{e4}|^2 \gtrsim 2\cdot10^{-2}. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results and improve the Troitsk bound for m42<m^2_{4} < 30 eV2^2. The reactor and gallium anomalies are constrained for 100<Δm412<1000 100 < Δ{m}^2_{41} < 1000 eV2^2.

preprint2011arXiv

Measurement of the gas-flow reduction factor of the KATRIN DPS2-F differential pumping section

The gas-flow reduction factor of the second forward Differential Pumping Section (DPS2-F) for the KATRIN experiment was determined using a dedicated vacuum-measurement setup and by detailed molecular-flow simulation of the DPS2-F beam tube and of the measurement apparatus. In the measurement, non-radioactive test gases deuterium, helium, neon, argon and krypton were used, the input gas flow was provided by a commercial mass-flow controller, and the output flow was measured using a residual gas analyzer, in order to distinguish it from the outgassing background. The measured reduction factor with the empty beam tube at room temperature for gases with mass 4 is 1.8(4)E4, which is in excellent agreement with the simulated value of 1.6E4. The simulated reduction factor for tritium, based on the interpolated value for the capture factor at the turbo-molecular pump inlet flange is 2.5E4. The difference with respect to the design value of 1E5 is due to the modifications in the beam tube geometry since the initial design, and can be partly recovered by reduction of the effective beam tube diameter.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.