Researcher profile

K. S. Kuznetsova

K. S. Kuznetsova contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
2close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Optimization of the metal-dielectric metasurface unit cell for sensitivity enhancement in determination of IgG concentration in solutions

This study focuses on developing a metal-dielectric sensor structure with optimized unit cell geometry for determination of protein Immunoglobulin G (IgG) concentration in aqueous solutions. The research combines both experimental and theoretical investigations, utilizing the differential microwave dielectrometry method and numerical modeling with COMSOL software. Complex permittivity (CP) values dependence of IgG water solutions on the protein concentration was experimentally obtained at the microwaves using original microwave dielectrometer setup. It was shown that increase of IgG concentration resulted in the CP values of the solutions studied decrease. The experimentally obtained CP data for the IgG water solutions were used as a basis for microwave metal-dielectric metasurface unit cell numerical modeling. The metal-dielectric metasurface consisting of Teflon substrate and plane copper microresonators was combined with a standard 96-well microplate used in clinical laboratories. Optimization of the obtained metasurface unit cell revealed that the size and position of the copper microresonators within the unit cell significantly impact the sensor sensitivity for determining the IgG concentration in aqueous solutions. The metasurface with the unit cell containing four copper microresonators provided the most sensitive platform for detecting variations in the IgG concentration in the sample. The frequency shift of the reflection coefficient was directly related to changes in the protein concentration. The calibration graph was developed for effective determination of IgG concentrations in the aqueous solutions.

preprint2026arXiv

Terahertz metasurface sensor with graphene microstrips for biosensing: modeling and application

The study is devoted to development and optimization of a metasurface-based sensor with graphene constituents for potential biosensing applications. A unit cell of the proposed metasurface consists of a thin flexible dielectric substrate layer with a centrally positioned graphene microstrip. As a result of numerical modeling of spectral properties of the metasurface by COMSOL Multiphysics software in terahertz range from 5 to 35 THz the absorption spectrum maxima (resonance modes) are revealed. The following stages of the study demonstrate that placement of a layer of tested liquid sample (water or Bovine Serum Albumin (BSA) solution) on the metasurface causes a low frequency shift of the plasmonic resonance mode chosen for biosensing measurements. This frequency shift, along with the change in the amplitude of the absorption peak, are highly sensitive to the refractive index of the tested liquid sample. The obtained results demonstrate the potential of the developed metasurface-based sensor with graphene microstrips for application as a sensing structure to determine proteins and other biomolecules in liquid samples.