Researcher profile

K. Jahoda

K. Jahoda contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
9works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2020arXiv

Global X-Ray Properties of the Vela and Puppis A Supernova Remnants

The Vela and Puppis A supernova remnants (SNRs) comprise a large emission region of $\sim 8^{\circ}$ diameter in the soft X-ray sky. The HaloSat CubeSat mission provides the first soft X-ray ($0.4-7$ keV) observation of the entire Vela SNR and Puppis A SNR region with a single pointing and moderate spectral resolution. HaloSat observations of the Vela SNR are best fit with a two-temperature thermal plasma model consisting of a cooler component with $kT_{1} = 0.19^{+0.01}_{-0.01}$ keV in collisional ionization equilibrium and a hotter component with $kT_{2} = 1.06^{+0.45}_{-0.27}$ keV in non-equilibrium ionization. Observations of the Puppis A SNR are best fit with a single-component plane-parallel shocked plasma model with $kT = 0.86^{+0.06}_{-0.05}$ keV in non-equilibrium ionization. For the first time, we find the total X-ray luminosities of both components of the Vela SNR spectrum in the $0.5-7$ keV energy band to be $L_X = 4.4^{+1.4}_{-1.4} \times 10^{34}$ erg s$^{-1}$ for the cooler component and $L_X = 4.1^{+1.8}_{-1.5} \times 10^{34}$ erg s$^{-1}$ for the hotter component. We find the total X-ray luminosities of the Vela and Puppis A SNRs to be $L_{\text{X}} = 8.4 \times 10^{34}$ erg s$^{-1}$ and $L_X = 6.7^{+1.1}_{-0.9} \times 10^{36}$ erg s$^{-1}$.

preprint2016arXiv

Performance of the PRAXyS X-ray Polarimeter

The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

preprint2013arXiv

Gas Gain Measurements from a Negative Ion TPC X-ray Polarimeter

Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good modulation when the drift distance is large. Therefore, we propose using a negative ion TPC (NITPC) with Nitromethane (CH3NO2) as the electron capture agent. The diffusion of negative ions is reduced over that of electrons due to the thermal coupling of the negative ions to the surrounding gas. This allows for larger area detectors as the drift distance can be increased without degrading polarimeter modulation. Negative ions also travel ~200 times slower than electrons, allowing the readout electronics to operate slower, resulting in a reduction of instrument power. To optimize the NITPC design, we have measured gas gain with SciEnergy gas electron multipliers (GEMs) in single and double GEM configurations. Each setup was tested with different gas combinations, concentrations and pressures: P10 700 Torr, Ne+CO2 700 Torr at varying concentrations of CO2 and Ne+CO2+CH3NO2 700 Torr. We report gain as a function of total voltage, measured from top to bottom of the GEM stack, and as a function of drift field strength for the gas concentrations listed above. Examples of photoelectron tracks at 5.9 keV are also presented.

preprint2010arXiv

On Calibrations using the Crab Nebula and Models of the Nebular X-ray Emission

Motivated by a paper (Kirsch et al. 2005) on possible use of the Crab Nebula as a standard candle for calibrating X-ray response functions, we examine consequences of intrinsic departures from a single (absorbed) power law upon such calibrations. We limit our analyses to three more modern X-ray instruments-the ROSAT/PSPC, the RXTE/PCA, and the XMM-Newton/EPIC-pn (burst mode). The results indicate a need to refine two of the three response functions studied. We are also able to distinguish between two current theoretical models for the system spectrum.

preprint2006arXiv

Calibration of the Rossi X-ray Timing Explorer Proportional Counter Array

We present the calibration and background model for the Proportional Counter Array (PCA) aboard the Rossi X-ray Timing Explorer (RXTE). The energy calibration is systematics limited below 10 keV with deviations from a power-law fit to the Crab nebula plus pulsar less than 1%. Unmodelled variations in the instrument background amount to less than 2% of the observed background below 10 keV and less than 1% between 10 and 20 keV. Individual photon arrival times are accurate to 4.4 micro-seconds at all times during the mission and to 2.5 micro-seconds after 29 April 1997. The peak pointing direction of the five collimators is known to a precision of a few arc-seconds

preprint2003arXiv

The imaging X-ray detector for Lobster-ISS

Lobster-ISS is a revolutionary astrophysical X-ray all-sky monitor scheduled for deployment as an attached payload on the International Space Station (ISS) in 2009. Using a new wide field-of-view focusing optic, Lobster-ISS provides an order-of-magnitude improvement in the sensitivity of all-sky monitors in the soft X-ray band (0.1-3.0 keV). This lobster-eye optic presents unique challenges to the imaging X-ray detector at its focus. Micro-patterned imaging proportional counters, with thier mechanical simplicity and high performance, are the most practical means of meeting the requirements. We describe our design for the Lobster-ISS imaging detector based on direct-imaging micro-well proportional counters and the expected performance.

preprint1999arXiv

X-ray Observations of BL Lacertae During 1997 Outburst and its Association with Quasar-like Characteristics

This paper reports on the X-ray emission from BL Lacertae during its July 1997 outburst as observed with the Rossi X-ray Timing Explorer (RXTE), compares the RXTE data to previous measurements, and interprets the overall electromagnetic emission in the context of the currently popular theoretical models. The source is bright and variable, with the 2 - 10 keV flux approximately two to three and a half times higher than measured in November 1995 by {\sl Asca}. The spectrum is also harder, with power law energy indices of $\sim 0.4 - 0.6$, compared to $\sim 0.9$ in Nov. 1995. Both in the optical band, where BL Lacertae now shows broad emission lines, and in the X-ray band, where the spectrum is hard, the overall electromagnetic distribution of BL Lacertae is similar to that observed in blazars associated with quasars rather than to that seen in the more common High-energy - peaked BL Lac - type objects (HBLs). We argue that the high energy (X-ray and $γ$-ray) emission from BL Lacertae consists of two spectral components: X-rays are produced by Comptonization of synchrotron radiation, while the $γ$-rays produced by Comptonization of the broad emission line flux.

preprint1998arXiv

RXTE Absolute Timing Results for the Pulsars B1821-24 and B1509-58

Observations with the Rossi X-ray Timing Explorer and the Jodrell Bank, Parkes, and Green Bank telescopes have enabled us to determine the time delay between radio and X-ray pulses in the two isolated pulsars B1821-24 and B1509-58. For the former we find that the narrow X-ray and radio pulse components are close to being coincident in time, with the radio peak leading by 0.02 period (60 +/- 20 microsec), while the wide X-ray pulse component lags the last of the two wider radio components by about 0.08 period. For the latter pulsar we find, using the standard value for the dispersion measure, that the X-ray pulse lags the radio by about 0.27 period, with no evidence for any energy-dependence in the range 2-100 keV. However, uncertainties in the history of the dispersion measure for this pulsar make a comparison with previous results difficult. It is clear that there are no perceptable variations in either the lag or the dispersion measure at time scales of a year or less.

preprint1996arXiv

RXTE Observation of Cygnus X-1 In Its High State

We present the results from the RXTE observations of Cygnus X-1 in its high state. In the energy range of 2-200 keV, the observed X-ray spectrum can be described by a model consisting of a soft blackbody component and a broken power-law with a high energy cutoff. The low energy spectrum (below about 11 keV) varies significantly from observation to observation while the high energy portion changes little. The X-ray flux varies on all timescales down to milliseconds. The power density spectrum (PDS) can be characterized by excess red noise (``1/f'') at low frequencies and a white noise component that extends to 1-3 Hz before being cut off. At higher frequencies, the PDS becomes power-law again, with a slope of roughly -2 (i.e., ``1/f^2''). Broad peaks in the range of 3-9 Hz are present, and might be due to quasi-periodic oscillations. The PDS shows interesting spectral dependence: the 1/f component becomes more prominent when the low-energy spectrum becomes softer. The difference in the observed spectral and timing properties between the low and high states is qualitatively consistent with a simple ``fluctuating corona'' model.