Source author record

K. Akiba

K. Akiba appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

20works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

20 published item(s)

preprint2026arXiv

Evidence for the rare decay $B^{+} \to \bar Λp μ^{+} μ^{-}$

A search for the rare decay $B^{+} \to \bar Λp μ^{+} μ^{-}$ is performed using proton-proton collision data recorded by the LHCb experiment at a center-of-mass energy of $\sqrt{s}= 13$ TeV, corresponding to an integrated luminosity of 5.4 fb$^-1$. An excess of events is found with respect to the background-only expectation, with a signal significance of 3.5 standard deviations, in the low invariant-mass region of $m(\bar Λp)<2.8$ GeV/$c^2$. The branching fraction is measured to be ${\cal B}_{\rm low}({B^{+}}\to {\bar Λp μ^{+} μ^{-}})=\left(1.70 ^{+0.65}_{-0.56}(\rm stat) \pm 0.17(\rm syst) \pm 0.14(\rm ext)\right) \times 10^{-8}$, where the last uncertainty is due to external inputs on ${\cal B}(B^+\to{J/ψ\bar Λp})\times {\cal B}({J/ψ}\to{μ^+μ^-})$. With no significant signal observed in the high $m(\bar Λp)$ region above 2.8 GeV/$c^2$, an upper limit is set to be ${\cal B}_{\rm high}(B^{+}\to {\bar Λp μ^{+} μ^{-}})<2.8\,(3.7) \times 10^{-9}$ at the $90\%$ ($95\%$) confidence level.

preprint2026arXiv

Measurement of transverse $Λ$ and $\barΛ$ hyperon polarization in $p$Pb collisions at $\sqrt{s_{NN}} = 5.02$ TeV

The transverse polarization of $Λ$ and $\barΛ$ hyperons is measured in $p$Pb collisions collected by the LHCb experiment at a nucleon-nucleon center-of-mass energy of $5.02$ TeV. The polarization is averaged over hyperon transverse momentum in the ranges $0.15 < p_{T} < 6.00 $ GeV/$c$, and Feynman-$x$ in the ranges $0.005 < x_{F} < 0.040$ (forward region) and $-0.10 < x_{F} < -0.01$ (backward region) defined relative to the proton beam direction. The transverse polarization is found to be compatible with zero for both $Λ$ and $\barΛ$ hyperons. The results are also measured as a function of $p_{T}$ and $x_{F}$ with no significant dependence on these variables observed. The results are compared with previous experimental measurements at different center-of-mass energies and collision environments.

preprint2026arXiv

Search for lepton-number-violating $B^-\to D^{(*)+}μ^-μ^-$ decays

A search is performed for lepton-number-violating $B^-\to D^{(*)+}μ^-μ^-$ decays, using data collected by the LHCb experiment in proton-proton collisions at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 5.4 fb$^{-1}$. No significant signal is observed, and upper limits are set on the branching fractions, ${\cal B}(B^-\to D^{+}μ^-μ^-) < 4.6 \times 10^{-8}$ and ${\cal B}(B^-\to D^{*+}μ^-μ^-) < 5.9 \times 10^{-8}$, at the 95% confidence level.

preprint2026arXiv

Study of charm mixing and CP violation with $D^0\to K^\pmπ^\mpπ^\pmπ^\mp$ decays

A study of charm mixing and CP violation in $D^0\to K^\pmπ^\mpπ^\pmπ^\mp$ decays is performed using data collected by the LHCb experiment in proton-proton collisions from 2015 to 2018, corresponding to an integrated luminosity of 6$\text{fb}^{-1}$. The ratio of promptly produced $D^0\to K^+π^- π^+π^-$ to $D^0\to K^-π^+ π^-π^+$ decay rates is measured as a function of $D^0$ decay time, both inclusive over phase space and in bins of phase space. Taking external inputs for the $D^0 -\overline{D}^0$ mixing parameters $x$ and $y$ allows constraints to be obtained on the hadronic parameters of the charm decay. When combined with previous measurements from charm-threshold experiments and at LHCb, improved knowledge is obtained for these parameters, which is valuable for studies of the angle $γ$ of the Unitarity Triangle. An alternative analysis is also performed, in which external inputs are taken for the hadronic parameters, and the mixing parameters are determined, including $Δx$ and $Δy$, which are nonzero in the presence of CP violation. It is found that $x=\left(0.85^{+0.15}_{-0.24}\right)\%$, $y=\left( 0.21^{+0.29}{-0.27} \right)\%$, $Δx=\left( -0.02\pm {0.04} \right)\% $ and $Δy=\left( 0.02^{+0.04}_{-0.03} \right)\%$. These results are consistent with previous measurements and the hypothesis of CP conservation.

preprint2025arXiv

Coherent photoproduction of $ρ^0, ω$ and excited vector mesons in ultraperipheral PbPb collisions

The invariant-mass distribution for the coherent photoproduction of dipions in ultraperipheral PbPb collisions is measured using data, corresponding to an integrated luminosity of $224.6 \pm 9.6 μ$b$^{-1}$, collected by the LHCb experiment in 2018 at a nucleon-nucleon centre-of-mass energy $\sqrt{s_{\rm NN}}=5.02$ TeV. In the mass range from 400 to 1200 MeV, the results are consistent with previous experiments, with the spectrum dominated by the $ρ^0$ meson, which interferes with a nonresonant component, together with a smaller $ω$ meson contribution. In an extended mass range up to 2300 MeV, models previously used do not fit the data and a consistent description requires the introduction of two resonances at masses of $1350\pm20$ MeV and $1790\pm20$ MeV with widths of about 300 MeV. The cross-section for each meson is measured differentially in twelve bins of rapidity from 2.05 to 4.90. The $ρ^0$ cross-section increases with rapidity from about 400 to 600 mb and is measured with a typical precision of 8\%, while the cross-section times branching fraction for the $ω,ρ^\prime$ and $ρ^{\prime\prime}$, with the statistical precision of the data, do not have a pronounced rapidity dependence and are between 0.5 and 1.5 mb, with uncertainties up to 30\%. A large nuclear suppression is observed for the $ρ^0$ meson compared to expectations based on photoproduction on the proton that use the impulse approximation. Significant suppression is also observed compared to that predicted by elastic scattering described in the Glauber approach, or with the addition of inelastic scattering in a Gribov--Glauber model.

preprint2022arXiv

Charge and temporal characterisation of silicon sensors using a two-photon absorption laser

First measurements are presented from a newly commissioned two-photon absorption (TPA) setup at Nikhef. The characterisation of the various components of the system is discussed. Two planar silicon sensors, one being electron collecting and one hole collecting, are characterised with detailed measurements of the charge collection and time resolution. The TPA spot is determined to have a radius of 0.975(11) $μ\text{m}$ and length of 23.8 $μ\text{m}$ in silicon. The trigger time resolution of the system is shown to be maximally 30.4 ps. For both sensors, uniform charge collection is observed over the pixels, and the pixel side metallisation is imaged directly using the TPA technique. The best time resolution for a single pixel is found to be 600 ps and 560 ps for the electron and hole collecting sensors respectively, and is dominated by ASIC contributions. Further scans at different depths in the sensor and positions within the pixels have been performed and show a uniform response. It is concluded that the TPA setup is a powerful tool to investigate the charge collection and temporal properties of silicon sensors.

preprint2022arXiv

Spatial resolution and efficiency of prototype sensors for the LHCb VELO Upgrade

A comprehensive study of the spatial resolution and detection efficiency of sensor prototypes developed for the LHCb VELO upgrade is presented. Data samples were collected at the CERN SPS H8 beam line using a hadron mixture of protons and pions with momenta of approximately 180 GeV/c. The sensor performance was characterised using both irradiated and non-irradiated sensors. Irradiated samples were subjected to a maximum fluence of $\mathrm{8\times10^{15}~1~MeV~n_{eq}~cm^{-2}}$, of both protons and neutrons. The spatial resolution is measured comparing the detected hits to the position as predicted by tracks reconstructed by the Timepix3 telescope. The resolution is presented for different applied bias voltages and track angles, sensor thickness and implant size.

preprint2022arXiv

The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform

The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector technologies. The Vertex Locator (VELO) surrounding the interaction region is used to reconstruct the collision points (primary vertices) and decay vertices of long-lived particles (secondary vertices). The upgraded VELO will be composed of 52 modules placed along the beam axis divided into two retractable halves. The modules will each be equipped with 4 silicon hybrid pixel tiles, each read out by 3 VeloPix ASICs. The total output data rate anticipated for the whole detector will be around 1.6 Tbit/s. The highest occupancy ASICs will have pixel hit rates of approximately 900 Mhit/s, with the corresponding output data rate of 15 Gbit/s. The LHCb upgrade detector will be the first detector to read out at the full LHC rate of 40 MHz. The VELO upgrade will utilize the latest detector technologies to read out at this rate while maintaining the required radiation-hard profile and minimizing the detector material.

preprint2022arXiv

Timing performance of the Timepix4 front-end

A characterisation of the Timepix4 pixel front-end with a strong focus on timing performance is presented. Externally generated test pulses were used to probe the per-pixel time-to-digital converter (TDC) and measure the time-bin sizes by precisely controlling the test-pulse arrival time in steps of 10 ps. The results indicate that the TDC can achieve a time resolution of 60 ps, provided that a calibration is performed to compensate for frequency variation in the voltage controlled oscillators of the pixel TDCs. The internal clock distribution system of Timepix4 was used to control the arrival time of internally generated analog test pulses in steps of about 20 ps. The analog test pulse mechanism injects a controlled amount of charge directly into the analog front-end (AFE) of the pixel, and was used to measure the time resolution as a function of signal charge, independently of the TDC. It was shown that for the default configuration, the AFE time resolution in the hole-collecting mode is limited to 105 ps. However, this can be improved up to about 60 ps by increasing the preamplifier bias-current at the cost of increased power dissipation. For the electron-collecting mode, an AFE time resolution of 47 ps was measured for a bare Timepix4 device at a signal charge of 21 ke. It was observed that additional input capacitance from a bonded sensor reduces this figure to 62 ps.

preprint2020arXiv

Large Enhancement of Thermoelectric Efficiency Due to a Pressure-Induced Lifshitz Transition in SnSe

Lifshitz transition, a change in Fermi surface topology, is likely to greatly influence exotic correlated phenomena in solids, such as high-temperature superconductivity and complex magnetism. However, since the observation of Fermi surfaces is generally difficult in the strongly correlated systems, a direct link between the Lifshitz transition and quantum phenomena has been elusive so far. Here, we report a marked impact of the pressure-induced Lifshitz transition on thermoelectric performance for SnSe, a promising thermoelectric material without strong electron correlation. By applying pressure up to 1.6 GPa, we have observed a large enhancement of thermoelectric power factor by more than 100% over a wide temperature range (10-300 K). Furthermore, the high carrier mobility enables the detection of quantum oscillations of resistivity, revealing the emergence of new Fermi pockets at ~0.86 GPa. The observed thermoelectric properties linked to the multi-valley band structure are quantitatively reproduced by first-principles calculations, providing novel insight into designing the SnSe-related materials for potential valleytronic as well as thermoelectric applications.

preprint2020arXiv

The HEV Ventilator

HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.

preprint2020arXiv

The HEV Ventilator Proposal

We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is in the concept and prototyping stage. It is presented here to invite fast feedback for development and deployment in the face of the COVID-19 pandemic.

preprint2016arXiv

Simultaneous Measurement of Resistively and Optically Detected Nuclear Magnetic Resonance in the $ν=2/3$ Fractional Quantum Hall Regime

We observe nuclear magnetic resonance (NMR) in the fractional quantum Hall regime at Landau level filling factor $ν=2/3$ from simultaneous measurement of longitudinal resistance and photoluminescence (PL). The dynamic nuclear spin polarization is induced by applying a huge electronic current at the spin phase transition point of $ν=2/3$. The NMR spectra obtained from changes in resistance and PL intensity are qualitatively the same; that is, the Knight shift (spin polarized region) and zero-shift (spin unpolarized region) resonances are observed in both. The observed change in PL intensity is interpreted as a consequence of the trion scattering induced by polarized nuclear spins. We conclude that both detection methods probe almost the same local phenomena.

preprint2015arXiv

Anisotropic nuclear-spin diffusion in double quantum wells

Nuclear-spin diffusion in double quantum wells (QWs) is examined by using dynamic nuclear polarization (DNP) at a Landau level filling factor $ν=2/3$ spin phase transition (SPT). The longitudinal resistance increases during the DNP of one of the two QW (the polarization QW) by means of a large applied current and starts to decrease just after the termination of the DNP. On the other hand, the longitudinal resistance of the other QW (the detection QW) continuously increases for approximately 2h after the termination of the DNP of the polarization QW. It is therefore concluded that the nuclear spins diffuse from the polarization QW to the detection QW. The time evolution of the longitudinal resistance of the polarization QW is explained mainly by the nuclear-spin diffusion in the in-plane direction. In contrast, that of the detection QW manifests much slower nuclear diffusion in the perpendicular direction through the AlGaAs barrier.

preprint2015arXiv

Optically Induced Nuclear Spin Polarization in the Quantum Hall Regime: The Effect of Electron Spin Polarization through Exciton and Trion Excitations

We study nuclear spin polarization in the quantum Hall regime through the optically pumped electron spin polarization in the lowest Landau level. The nuclear spin polarization is measured as a nuclear magnetic field $B_N$ by means of the sensitive resistive detection. We find the dependence of $B_N$ on filling factor unmonotonous. The comprehensive measurements of $B_N$ with the help of the circularly polarized photoluminescence measurements indicate the participation of the photo-excited complexes i.e., the exciton and trion (charged exciton), in nuclear spin polarization. On the basis of a novel estimation method of the equilibrium electron spin polarization, we analyze the experimental data and conclude that the filling factor dependence of $B_N$ is understood by the effect of electron spin polarization through excitons and trions.

preprint2014arXiv

A GEANT4 based Simulation for Pixelated X-ray Hybrid Detectors: Extended Report

Monte Carlo simulations are powerful tools for understanding the effects of radiation interactions within detector devices allowing not only to evaluate typical estimates for experimental measurements and to serve as means for designing experiments but to provide additional information that are usually not easily accessible experimentally. A simple numerical approach to describe the functioning of pixelated detectors is presented in this paper. Estimates from a variety of simulated setups are obtained and the observed features compared with experimental results to verify to which extent they are correctly described by this method. Fundamental curves such as interaction probability and reconstructed energy deposited are calculated as function of beam energy. Pixel response, charge sharing effects and resolution estimates are also obtained.

preprint2014arXiv

Performance of the LHCb Vertex Locator

The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 microns is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 micron for translations in the plane transverse to the beam. A primary vertex resolution of 13 microns in the transverse plane and 71 microns along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 microns is achieved for particles with transverse momentum greater than 1 GeV/c.

preprint2013arXiv

Optically induced nuclear spin polarization in a single GaAs/AlGaAs quantum well probed by a resistance detection method in the fractional quantum Hall regime

We study the optically pumped nuclear spin polarization in a single GaAs/AlGaAs quantum well in the quantum Hall system. We apply resistive detection via the contact hyperfine interaction, which provides high sensitivity and selectivity, to probe a small amount of polarized nuclear spins in a single well. The properties of the optical nuclear spin polarization are clearly observed. We theoretically discuss the nuclear spin dynamics accompanied with doped electrons to analyze the experimental data. The optical nuclear polarization spectra exhibit electron-spin-resolved lowest Landau level interband transitions. We find that the phonon emission process, which normally assists the optical pumping process, influences the optical nuclear spin polarization. We also discuss that the electron-electron interaction can play an important role in the optical nuclear spin polarization.

preprint2013arXiv

Radiation damage in the LHCb Vertex Locator

The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the operational sensor temperature of approximately $-7\,^{\circ}\rm{C}$, the average rate of sensor current increase is $18\,\upmu\rm{A}$ per $\rm{fb^{-1}}$, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of $E_{g}=1.16\pm0.03\pm0.04\,\rm{eV}$ obtained. The first observation of n-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around $15 \times 10 ^{12}$ of $1\,\rm{MeV\,n_{eq}}$. The only n-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately $\rm{3 \times 10^{12}\,1\,MeV\,n_{eq}}$, a decrease in the Effective Depletion Voltage (EDV) of around 25\,V is observed, attributed to oxygen induced removal of boron interstitial sites. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n-on-n type sensors, with rates of $(1.43\pm 0.16) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ and $(1.35\pm 0.25) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ measured for n-on-p and n-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed.

preprint2009arXiv

Storage and retrieval of nonclassical photon pairs and conditional single photons generated by parametric down-conversion process

Storage and retrieval of parametric down-conversion (PDC) photons are demonstrated with electromagnetically induced transparency (EIT). Extreme frequency filtering is performed for THz order of broadband PDC light and the frequency bandwidth of the light is reduced to MHz order. Storage and retrieval procedures are carried out for the frequency filtered PDC photons. Since the filtered bandwidth [full width at half-maximum (FWHM) = 9 MHz] is within the EIT window (FWHM = 12.6 MHz), the flux of the PDC light is successfully stored and retrieved. The nonclassicality of the retrieved light is confirmed by using photon counting method, where the classical inequality which is only satisfied for classical light fields is introduced. Since the PDC photons can be utilized for producing the single photon state conditionally, storage and retrieval procedures are also performed for the conditional single photons. Anti-correlation parameter used for checking the property of single photon state shows the value less than 1, which means the retrieved light is in a non-classical region.