Source author record

Jonathan Keelan

Jonathan Keelan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Mitigating the effects of particle background on the Athena Wide-Field Imager

The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

preprint2022arXiv

Three dimensional simulations of embolic stroke: clinical comparisons and an equation for sizing emboli from imaging

There is a need to develop Monte Carlo simulations of stroke to run in-silico trials to replace animal models, explore clinical scenarios to develop hypotheses for clinical studies and for interpreting clinical monitoring. We perform three-dimensional (3D) stroke simulations, carrying out in-silico trials to relate lesion volume to embolus diameter and calculate probabilistic lesion overlap maps, building on our previous Monte Carlo method. Simulated emboli were released into a 3D in silico vasculature, supplying gray and white matter brain volumes, to generate individual lesion estimates and probabilistic lesion overlap maps. Computer generated lesions were assessed by clinicians and compared with real world radiological images. Simulations of large single emboli reproduced similar middle cerebral artery (MCA), posterior cerebral artery (PCA) and anterior cerebral artery (ACA) lesions to those observed clinically. A proof-of-concept in-silico trial led to a conjecture relating estimated infarct volume as a percentage of total brain volume to relative embolus diameter: $\mathrm{relative diameter} = [\% \mathrm{infarct volume} / a]^{1/b}$, where $a= 104.2 \pm 0.98$, $b=3.380 \pm 0.030$. Probabilistic lesion overlap maps were created, confirming the MCA territory as the most probable resting place of emboli in the computational vasculature, followed by the PCA then ACA. The article shows proof of concept for developing a 3D stroke model from an automatically constructed vasculature.

preprint2020arXiv

The role of vascular complexity on optimal junction exponents

We examine the role of complexity on arterial tree structures, determining globally optimal vessel arrangements using the Simulated AnneaLing Vascular Optimization (SALVO) algorithm, which we have previously used to reproduce features of cardiac and cerebral vasculatures. Fundamental biophysical understanding of complex vascular structure has applications to modelling of cardiovascular diseases, and for improved representations of vasculatures in large artificial tissues. In order to progress in-silico methods for growing arterial networks, we need to understand the stability of computational arterial growth algorithms to complexity, variations in physiological parameters such as tissue demand, and underlying assumptions regarding the value of junction exponents. We determine the globally optimal structure of two-dimensional arterial trees; analysing sensitivity of tree morphology and optimal bifurcation exponent to physiological parameters. We find that, for physiologically relevant simulation parameters, arterial structure is stable, whereas optimal junction exponents vary. We conclude that the full complexity of arterial trees is essential for determining the fundamental properties of vasculatures. These results are important for establishing that optimisation-based arterial growth algorithms are stable against uncertainties in physiological parameters, while identifying that optimal bifurcation exponents (a key parameter for many arterial growth algorithms) are sensitive to complexity and the boundary conditions dictated by organs.

preprint2016arXiv

Simulated annealing approach to vascular structure with application to the coronary arteries

Does the complex processes of angiogenesis during organism development ultimately lead to a near optimal coronary vasculature in the organs of adult mammals? We examine this hypothesis using a powerful and universal method, built on physical and physiological principles, for the determination of globally energetically optimal arterial trees. The method is based on simulated annealing, and can be used to examine arteries in hollow organs with arbitrary tissue geometries. We demonstrate that the approach can generate in-silico vasculatures which closely match porcine anatomical data for the coronary arteries on all length scales, and that the optimised arterial trees improve systematically as computational time increases. The method presented here is general, and could in principle be used to examine the arteries of other organs. Potential applications include improvement of medical imaging analysis and the design of vascular trees for artificial organs.