Researcher profile

John Groh

John Groh contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Phase Drift Monitoring for Tone Tracking Readout of Superconducting Microwave Resonators

A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID Multiplexers ($μ$mux) and Microwave Kinetic Inductance Detectors. In these readout schemes, sky signal is encoded as resonance frequency changes. One way to interrogate these superconducting resonators is to calibrate the probe tone phase such that any sky signal induced frequency shifts from the resonators show up primarily as voltage changes in only one of the two quadratures of the interrogation tone. However, temperature variations in the operating environment produce phase drifts that degrade the phase calibration and can source low frequency noise in the final detector time ordered data if left to drift too far from optimal calibration. We present a method for active software monitoring of the time delay through the system which could be used to feedback on the resonator probe tone calibration angle or to apply an offline cleaning. We implement and demonstrate this monitoring method using the SLAC Microresonator RF Electronics on a 65 channel $μ$mux chip from NIST.

preprint2022arXiv

Simons Observatory Focal-Plane Module: Detector Re-biasing With Bias-step Measurements

The Simons Observatory is a ground-based cosmic microwave background survey experiment that consists of three 0.5 m small-aperture telescopes and one 6 m large-aperture telescope, sited at an elevation of 5200 m in the Atacama Desert in Chile. SO will deploy 60,000 transition-edge sensor (TES) bolometers in 49 separate focal-plane modules across a suite of four telescopes covering 30/40 GHz low frequency (LF), 90/150 GHz mid frequency (MF), and 220/280 GHz ultra-high frequency (UHF). Each MF and UHF focal-plane module packages 1720 optical detectors spreading across 12 detector bias lines that provide voltage biasing to the detectors. During observation, detectors are subject to varying atmospheric emission and hence need to be re-biased accordingly. The re-biasing process includes measuring the detector properties such as the TES resistance and responsivity in a fast manner. Based on the result, detectors within one bias line then are biased with suitable voltage. Here we describe a technique for re-biasing detectors in the modules using the result from bias-step measurement.