Source author record

Johanan Codona

Johanan Codona appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Calibrating a high-resolution wavefront corrector with a static focal-plane camera

We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential optical transfer functions (dOTF) to compute both the phase and amplitude in the pupil plane located upstream of the last imaging optics. An experiment with a spatial light modulator shows that the calibration is sufficient to robustly operate a focal-plane wavefront sensing algorithm controlling a wavefront corrector with ~40 000 degrees of freedom. We estimate that the locations of identical wavefront corrector elements are determined with a spatial resolution of 0.3% compared to the pupil diameter.

preprint2012arXiv

The Vector-APP: a Broadband Apodizing Phase Plate that yields Complementary PSFs

The apodizing phase plate (APP) is a solid-state pupil optic that clears out a D-shaped area next to the core of the ensuing PSF. To make the APP more efficient for high-contrast imaging, its bandwidth should be as large as possible, and the location of the D-shaped area should be easily swapped to the other side of the PSF. We present the design of a broadband APP that yields two PSFs that have the opposite sides cleared out. Both properties are enabled by a half-wave liquid crystal layer, for which the local fast axis orientation over the pupil is forced to follow the required phase structure. For each of the two circular polarization states, the required phase apodization is thus obtained, and, moreover, the PSFs after a quarter-wave plate and a polarizing beam-splitter are complementary due to the antisymmetric nature of the phase apodization. The device can be achromatized in the same way as half-wave plates of the Pancharatnam type or by layering self-aligning twisted liquid crystals to form a monolithic film called a multi-twist retarder. As the VAPP introduces a known phase diversity between the two PSFs, they may be used directly for wavefront sensing. By applying an additional quarter-wave plate in front, the device also acts as a regular polarizing beam-splitter, which therefore furnishes high-contrast polarimetric imaging. If the PSF core is not saturated, the polarimetric dual-beam correction can also be applied to polarized circumstellar structure. The prototype results show the viability of the vector-APP concept.

preprint2006arXiv

Telescope to Observe Planetary Systems (TOPS): a high throughput 1.2-m visible telescope with a small inner working angle

The Telescope to Observe Planetary Systems (TOPS) is a proposed space mission to image in the visible (0.4-0.9 micron) planetary systems of nearby stars simultaneously in 16 spectral bands (resolution R~20). For the ~10 most favorable stars, it will have the sensitivity to discover 2 R_E rocky planets within habitable zones and characterize their surfaces or atmospheres through spectrophotometry. Many more massive planets and debris discs will be imaged and characterized for the first time. With a 1.2m visible telescope, the proposed mission achieves its power by exploiting the most efficient and robust coronagraphic and wavefront control techniques. The Phase-Induced Amplitude Apodization (PIAA) coronagraph used by TOPS allows planet detection at 2 lambda/d with nearly 100% throughput and preserves the telescope angular resolution. An efficient focal plane wavefront sensing scheme accurately measures wavefront aberrations which are fed back to the telescope active primary mirror. Fine wavefront control is also performed independently in each of 4 spectral channels, resulting in a system that is robust to wavefront chromaticity.