Researcher profile

Jifeng Qu

Jifeng Qu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Improved electronic measurement of the Boltzmann constant by Johnson noise Thermometry

The unit of thermodynamic temperature, the kelvin, will be redefined in 2018 by fixing the value of the Boltzmann constant, k. The present CODATA recommended value of k is determined predominantly by acoustic gas-thermometry results. To provide a value of k based on different physical principles, purely electronic measurements of k were performed by using a Johnson noise thermometer to compare the thermal noise power of a 200 Ohm sensing resistor immersed in a triple-point-of-water cell to the noise power of a quantum-accurate pseudo-random noise waveform of nominally equal noise power. Measurements integrated over a bandwidth of 550 kHz and a total integration time of 33 days gave a measured value of k = 1.3806514(48)x10^-23 J/K, for which the relative standard uncertainty is 3.5x10^-6 and the relative offset from the CODATA 2010 value is +1.9x10^-6.

preprint2011arXiv

An Electronic Measurement of the Boltzmann Constant

The Boltzmann constant was measured by comparing the Johnson noise of a resistor at the triple point of water with a quantum-based voltage reference signal generated with a superconducting Josephson-junction waveform synthesizer. The measured value of k = 1.380651(18) \times 10^-23 J/K is consistent with the current CODATA value and the combined uncertainties. This is our first measurement of k with this electronic technique, and the first noise thermometry measurement to achieve a relative combined uncertainty of 13 parts in 10^6. We describe the most recent improvements to our Johnson Noise Thermometer that enabled the statistical uncertainty contribution to be reduced to seven parts in 10^6, as well as the further reduction of spurious systematic errors and EMI effects. The uncertainty budget for this measurement is discussed in detail.