Researcher profile

Jianbei Liu

Jianbei Liu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2025arXiv

A Low Background Beta Detection System using a Time Projection Chamber

In this paper, we present a Time Projection Chamber (TPC) system for low-background beta radiation measurements. The system consists of a TPC with two-dimensional-strip readout Micromegas and an anti-coincidence detector with readout pads for cosmic ray veto. The detector system utilize an AGET-based waveform sampling system for data acquisition. The beta detection capability of the system was verified through experimental test using $^{90}$Sr beta source. Additionally, a dedicated simulation program based on Geant4 was developed to model the entire detection process, including responses to both the beta source and background radiation. Simulation results were compared with experimental data for both beta and background samples, showing good agreements. The simulation samples were utilized to optimize and train classification models for beta and background discrimination. By applying the selected model into test data, the system achieved a background rate of 0.49 $\rm cpm/cm^2$ while retaining more than 55% of $^{90}$Sr beta signals within a 7 cm diameter detection region. Further analysis revealed that approximately 70% of the background originates from environmental gamma radiation, while the remaining contribution mainly comes from intrinsic radioactivity of detector materials, particularly the FR-4 based field cage and readout plane. Based on the knowledge gained from the experiments and simulations, an optimization of the TPC system has been proposed, with simulation predicting a potential reduction of the background rate to 0.0012 $\rm cpm/cm^2$.

preprint2020arXiv

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

preprint2020arXiv

Optimization study of scintillator shape of electromagnetic calorimeter for Higgs factories

Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order to meet these requirements, scintillator strips with a small dimple has been proposed. In our study, we measure the light yield of a dimple scintillator sample; we then compare the measurements with light tracing simulation using GEANT4. We intend to use our results to propose an optimized scintillator shape.

preprint2020arXiv

Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.