Researcher profile

Jian-Qing Zheng

Jian-Qing Zheng contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

A Compacted Structure for Cross-domain learning on Monocular Depth and Flow Estimation

Accurate motion and depth recovery is important for many robot vision tasks including autonomous driving. Most previous studies have achieved cooperative multi-task interaction via either pre-defined loss functions or cross-domain prediction. This paper presents a multi-task scheme that achieves mutual assistance by means of our Flow to Depth (F2D), Depth to Flow (D2F), and Exponential Moving Average (EMA). F2D and D2F mechanisms enable multi-scale information integration between optical flow and depth domain based on differentiable shallow nets. A dual-head mechanism is used to predict optical flow for rigid and non-rigid motion based on a divide-and-conquer manner, which significantly improves the optical flow estimation performance. Furthermore, to make the prediction more robust and stable, EMA is used for our multi-task training. Experimental results on KITTI datasets show that our multi-task scheme outperforms other multi-task schemes and provide marked improvements on the prediction results.

preprint2021arXiv

D-Net: Siamese based Network with Mutual Attention for Volume Alignment

Alignment of contrast and non-contrast-enhanced imaging is essential for the quantification of changes in several biomedical applications. In particular, the extraction of cartilage shape from contrast-enhanced Computed Tomography (CT) of tibiae requires accurate alignment of the bone, currently performed manually. Existing deep learning-based methods for alignment require a common template or are limited in rotation range. Therefore, we present a novel network, D-net, to estimate arbitrary rotation and translation between 3D CT scans that additionally does not require a prior standard template. D-net is an extension to the branched Siamese encoder-decoder structure connected by new mutual non-local links, which efficiently capture long-range connections of similar features between two branches. The 3D supervised network is trained and validated using preclinical CT scans of mouse tibiae with and without contrast enhancement in cartilage. The presented results show a significant improvement in the estimation of CT alignment, outperforming the current comparable methods.

preprint2020arXiv

ACNN: a Full Resolution DCNN for Medical Image Segmentation

Deep Convolutional Neural Networks (DCNNs) are used extensively in medical image segmentation and hence 3D navigation for robot-assisted Minimally Invasive Surgeries (MISs). However, current DCNNs usually use down sampling layers for increasing the receptive field and gaining abstract semantic information. These down sampling layers decrease the spatial dimension of feature maps, which can be detrimental to image segmentation. Atrous convolution is an alternative for the down sampling layer. It increases the receptive field whilst maintains the spatial dimension of feature maps. In this paper, a method for effective atrous rate setting is proposed to achieve the largest and fully-covered receptive field with a minimum number of atrous convolutional layers. Furthermore, a new and full resolution DCNN - Atrous Convolutional Neural Network (ACNN), which incorporates cascaded atrous II-blocks, residual learning and Instance Normalization (IN) is proposed. Application results of the proposed ACNN to Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) image segmentation demonstrate that the proposed ACNN can achieve higher segmentation Intersection over Unions (IoUs) than U-Net and Deeplabv3+, but with reduced trainable parameters.

preprint2019arXiv

Real-time 3D Shape Instantiation for Partially-deployed Stent Segment from a Single 2D Fluoroscopic Image in Robot-assisted Fenestrated Endovascular Aortic Repair

In robot-assisted Fenestrated Endovascular Aortic Repair (FEVAR), accurate alignment of stent graft fenestrations or scallops with aortic branches is essential for establishing complete blood flow perfusion. Current navigation is largely based on 2D fluoroscopic images, which lacks 3D anatomical information, thus causing longer operation time as well as high risks of radiation exposure. Previously, 3D shape instantiation frameworks for real-time 3D shape reconstruction of fully-deployed or fully-compressed stent graft from a single 2D fluoroscopic image have been proposed for 3D navigation in robot-assisted FEVAR. However, these methods could not instantiate partially-deployed stent segments, as the 3D marker references are unknown. In this paper, an adapted Graph Convolutional Network (GCN) is proposed to predict 3D marker references from 3D fully-deployed markers. As original GCN is for classification, in this paper, the coarsening layers are removed and the softmax function at the network end is replaced with linear mapping for the regression task. The derived 3D and the 2D marker references are used to instantiate partially-deployed stent segment shape with the existing 3D shape instantiation framework. Validations were performed on three commonly used stent grafts and five patient-specific 3D printed aortic aneurysm phantoms. Comparable performances with average mesh distance errors of 1$\sim$3mm and average angular errors around 7degree were achieved.