Source author record

Jens Schmid

Jens Schmid appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Photonic Temperature and Wavelength Metrology by Spectral Pattern Recognition

Spectral pattern recognition is used to measure temperature and generate calibrated wavelength/frequency combs using a single silicon waveguide ring resonator. The ring generates two incommensurate interleaving TE and TM spectral combs that shift independently with temperature to create a spectral pattern that is unique at every temperature. Following an initial calibration, the ring temperature can be determined by recognizing the spectral resonance pattern, and as a consequence the wavelength of every resonance is also known. Two methods of pattern based temperature retrieval are presented. In the first method, the ring is locked to a previously determined temperature set-point defined by the coincidence of only two specific TE and TM cavity modes. Based on a prior calibration at the set-point, the ring temperature and hence all resonance wavelengths are then known and the resulting comb can be used as a wavelength calibration reference. In this configuration, all reference comb wavelengths have been reproduced within a 5 pm accuracy across an 80 nm range by using an on-chip micro-heater to tune the ring. For more general photonic thermometry, a spectral correlation algorithm is developed to recognize a resonance pattern across a 30 nm wide spectral window and thereby determine ring temperature continuously to 50 mK accuracy. The correlation method is extended to simultaneously determine temperature and to identify and correct for wavelength calibration errors in the interrogating light source. The temperature and comb wavelength accuracy is limited primarily by the linewidth of the ring resonances, with accuracy and resolution scaling with the ring quality factor.

preprint2016arXiv

Ultra broadband waveveguide coupler using an anisotropic sub-wavelength metamaterial

Multimode interference couplers are a fundamental building block in many integrated photonic systems, ranging from high-speed coherent receivers to quantum splitters. However, their basic structure has remained fundamentally unchanged for almost four decades, limiting their size and operation bandwidth. Using sub-wavelength metamaterials, photonic devices with break-through size and performance have been recently reported. Leveraging the inherent anisotropy of these structures, here we derive a semi-analytic expression that enables the design of compact and ultra broadband multimode interference couplers. We experimentally demonstrate virtually perfect operation over a bandwidth in excess of 300nm (500nm in simulation), for a device three times shorter than its conventional counterpart, making this the most broadband multimode interference coupler reported to date. These results will enable ultra broadband integrated systems for applications in communications and sensing.