Researcher profile

Jeanette Hussong

Jeanette Hussong contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Delaying Leading Edge Vortex Detachment by Plasma Flow Control at Topologically Critical Locations

Flapping wing propulsion offers unrivalled manoeuvrability and efficiency at low flight speeds and in hover. These advantages are attributed to the leading edge vortex developing on an unsteady wing, which induces additional lift. We propose and validate a manipulation hypothesis that allows prolongation of the leading edge vortex growth phase, by delaying its detachment with the aid of flow control. This approach targets an overall lift increase on unsteady airfoils. A dielectric barrier discharge plasma actuator is successfully used to compress secondary structures upstream of the main vortex on a pitching and plunging flat plate. To determine flow control timing and location, the tangential velocity on the airfoil surface is used, which is also used to quantify topological effects of flow control. This flow control is then tested for different motion kinematics and on a NACA 0012 airfoil. Significant increase of the peak circulation of the leading edge vortex of about 20% for all cases with flow control indicates that this approach is applicable for various kinematics, dynamics and airfoil types.

preprint2020arXiv

Insights into Leading Edge Vortex Formation and Detachment on a Pitching and Plunging Flat Plate

The present study is a prelude to applying different flow control devices on pitching and plunging airfoils with the intention of controlling the growth of the leading edge vortex (LEV); hence, the lift under unsteady stall conditions. As a pre-requisite, the parameters influencing the development of the LEV topology must be fully understood, and this constitutes the main motivation of the present experimental investigation. The aims of this study are twofold. First, an approach is introduced to validate the comparability between flow fields and LEV characteristics of two different facilities using water and air as working media by making use of a common baseline case. The motivation behind this comparison is that with two facilities the overall parameter range can be greatly expanded. This comparison includes an overview of the respective parameter ranges, control of the airfoil kinematics and careful scrutiny of how post-processing procedures of velocity data from time-resolved particle image velocimetry (PIV) influence the integral properties and topological features used to characterise the LEV development. Second, and based on results coming from both facilities, the appearance of secondary structures and their effect on LEV detachment over an extended parameter range is studied. A Lagrangian flow field analysis, based on finite-time Lyapunov Exponent (FTLE) ridges, allows precise identification of secondary structures and reveals that their emergence is closely correlated to a vortex Reynolds number threshold computed from the LEV circulation. This threshold is used to model the temporal onset of secondary structures. Further analysis indicates that the emergence of secondary structures causes the LEV to stop accumulating circulation if the shear layer angle at the leading edge of the flat plate has ceased to increase.

preprint2020arXiv

On the calibration of Astigmatism particle tracking velocimetryfor suspensions of different volume fractions

In the present study we demonstrate for the first time how Astigmatism Particle Tracking Velocimetry (APTV) can be utilized to measure suspensions dynamics. Measurements were successfully performed in monodisperse, refractive index matched suspensions of up to a volume fraction of $Φ=19.9\%$. For this, a small percentage of the particles is labeled with fluorescent dye acting as tracers for the particle tracking procedure. Calibration results show, that a slight deviation of the refractive index of liquid and particles leads to a strong shape change of the calibration curve with respect to the unladen case. This effect becomes more severe along the channel height. To compensate the shape change of the calibration curves the interpolation technique developed by Brockmann et al. (Experiments in Fluids, 61(2), 67, \citeyear{brockmann2020utilizing}) is adapted. Using this technique, the interpolation procedure is applied to suspensions with 6 different volume fractions ranging from $Φ<0.01\%$ to $Φ=19.9\%$. To determine the effect of volume fraction on the perfomance of the method, the depth reconstruction error $σ_z$ and the measurement volume depth $Δz$, obtained in different calibration measurements, are estimated. Here, a relative position reconstruction accuracy of $σ_z$/$Δz$=0.90\% and $σ_z$/$Δz$=2.53\% is achieved for labeled calibration particles in dilute ($Φ<0.01\%$) and semi-dilute ($Φ\approx19.9\%$) suspensions, respectively. The measurement technique is validated for a laminar flow in a straight rectangular channel with a cross-sectional area of 2.55$\times$30\,mm$^2$. Uncertainties of 1.39\% and 3.34\% for the in-plane and 9.04\% and 22.57\% for the out-of-plane velocity with respect to the maximum streamwise velocity are achieved, at solid volume fractions of $Φ<0.01\%$ and $Φ=19.9\%$, respectively.