Researcher profile

Jean-Claude Tinguely

Jean-Claude Tinguely contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Transmission Structured Illumination Microscopy using Tilt-mirror Assembly

We present experimental demonstration of tilt-mirror assisted transmission structured illumination microscopy (tSIM) that offers a large field of view super resolution imaging. An assembly of custom-designed tilt-mirrors are employed as the illumination module where the sample is excited with the interference of two beams reflected from the opposite pair of mirror facets. Tunable frequency structured patterns are generated by changing the mirror-tilt angle and the hexagonal-symmetric arrangement is considered for the isotropic resolution in three orientations. Utilizing high numerical aperture (NA) objective in standard SIM provides super-resolution compromising with the field-of-view (FOV). Employing low NA (20X/0.4) objective lens detection, we experimentally demonstrate ~ (0.56mm x 0.35mm) size single FOV image with ~1.7- and ~2.4-fold resolution improvement (exploiting various illumination by tuning tilt-mirrors) over the diffraction limit. The results are verified both for the fluorescent beads as well as biological samples. The tSIM geometry decouples the illumination and the collection light paths consequently enabling free change of the imaging objective lens without influencing the spatial frequency of the illumination pattern that are defined by the tilt-mirrors. The large and scalable FoV supported by tSIM will find usage for applications where scanning large areas are necessary as in pathology and applications where images must be correlated both in space and time.

preprint2020arXiv

Multi-modal on-chip nanoscopy and quantitative phase image reveals the morphology of liver sinusoidal enodthelial cells

Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a lateral optical resolution of 61 nm combined with a highly sensitive quantitative phase microscopy (QPM) system with a spatial phase sensitivity of $\pm$20 mrad. We use the system to obtain the 3D morphology of liver sinusoidal endothelial cells (LSECs) combined with super-resolved spatial information. LSECs have a unique morphology with nanopores that are present in the plasma membrane, called fenestration. The fenestrations are grouped in clusters called sieve plates, which are around 100 nm thick. Thus, imaging and quantification of fenestration and sieve plate thickness requires resolution and sensitivity of sub-100 nm along both lateral and axial directions. In the chip-based nanoscope, the optical waveguides are used both for hosting and illuminating the sample. A strong evanescent field is generated on top of the waveguide surface for single molecule fluorescence excitation. The fluorescence signal is captured by an upright microscope, which is converted into a Linnik-type interferometer to sequentially acquire both super-resolved images and quantitative phase information of the sample. The multi-modal microscope provided an estimate of the fenestration diameter of 124$\pm$41 nm and revealed the average estimated thickness of the sieve plates in the range of 91.2$\pm$43.5 nm for two different cells. The combination of these techniques offers visualization of both the lateral size (using nanoscopy) and the thickness map of sieve plates, i.e. discrete clusters fenestrations in QPM mode.

preprint2019arXiv

Structured illumination microscopy using a photonic chip

Structured illumination microscopy (SIM) enables live cell, super-resolution imaging at high speeds. SIM uses sophisticated optical systems to generate pre-determined excitation light patterns, and reconstruction algorithms to enhance the resolution by up to a factor of two. The optical set-up of SIM relies on delicate free-space optics to generate the light patterns, and a high numerical aperture objective lens to project the pattern on the sample. These arrangements are prone to miss-alignment, often with high costs, and with the final resolution-enhancement being limited by the numerical aperture of the collection optics. Here, we present a photonic-chip based total internal reflection fluorescence (TIRF)-SIM that greatly reduces the complexity of the optical setup needed to acquire TIRF-SIM images. This is achieved by taking out the light delivery from the microscope and transferring it to a photonic-chip. The conventional glass slide is replaced by the planar photonic chip, that both holds and illuminates the specimen. The chip is used to create a standing wave interference pattern, which illuminates the sample via evanescent fields. The phase of the interference pattern is controlled by the use of thermo-optical modulation, leaving the footprint of the light illumination path for the SIM system to around 4 by 4 cm$^2$. Furthermore, we show that by the use of the photonic-chip technology, the resolution enhancement of SIM can be increased above that of the conventional approach. In addition, by the separation of excitation and collection light paths the technology opens the possibility to use low numerical objective lenses, without sacrificing on the SIM resolution. Chip-based SIM represents a simple, stable and affordable approach, which could enable widespread penetration of the technique and might also open avenues for high throughput optical super-resolution microscopy.