Researcher profile

Javier Escudero

Javier Escudero contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2023arXiv

Stratified Multivariate Multiscale Dispersion Entropy for Physiological Signal Analysis

Multivariate entropy quantification algorithms are becoming a prominent tool for the extraction of information from multi-channel physiological time-series. However, in the analysis of physiological signals from heterogeneous organ systems, certain channels may overshadow the patterns of others, resulting in information loss. Here, we introduce the framework of Stratified Entropy to prioritize each channels' dynamics based on their allocation to respective strata, leading to a richer description of the multi-channel time-series. As an implementation of the framework, three algorithmic variations of the Stratified Multivariate Multiscale Dispersion Entropy are introduced. These variations and the original algorithm are applied to synthetic time-series, waveform physiological time-series, and derivative physiological data. Based on the synthetic time-series experiments, the variations successfully prioritize channels following their strata allocation while maintaining the low computation time of the original algorithm. In experiments on waveform physiological time-series and derivative physiological data, increased discrimination capacity was noted for multiple strata allocations in the variations when benchmarked to the original algorithm. This suggests improved physiological state monitoring by the variations. Furthermore, our variations can be modified to utilize a priori knowledge for the stratification of channels. Thus, our research provides a novel approach for the extraction of previously inaccessible information from multi-channel time series acquired from heterogeneous systems.

preprint2022arXiv

Hybrid Artifact Detection System for Minute Resolution Blood Pressure Signals from ICU

Physiological monitoring in intensive care units (ICU) generates data that can be used in clinical research. However, the recording conditions in clinical settings limit the automated extraction of relevant information from physiological signals due to noise and artifacts. Therefore, removing artifacts before clinical research is essential. Manual annotation by experienced researchers, which is the gold standard for removing artifacts, is time-consuming and costly due to the volume of the data generated in the ICU. In this study, we propose a hybrid artifact detection system that combines a Variational Autoencoder with a statistical detection component for the labeling of artifactual samples to automate the costly process of cleaning physiological recordings. The system is applied to minute-by-minute mean blood pressure signals from an intensive care unit dataset. Its performance is verified by manual annotations made by an expert. We benchmark the performance of our system with two other systems that combine an ARIMA or an autoencoder-based model with our statistical detection component. Our results indicate that the system consistently achieves sensitivity and specificity levels of over 90%. Thus, it provides an initial foundation to automate data cleaning in recordings from ICU.

preprint2022arXiv

Multivariate permutation entropy, a Cartesian graph product approach

Entropy metrics are nonlinear measures to quantify the complexity of time series. Among them, permutation entropy is a common metric due to its robustness and fast computation. Multivariate entropy metrics techniques are needed to analyse data consisting of more than one time series. To this end, we present a multivariate permutation entropy, $MPE_G$, using a graph-based approach. Given a multivariate signal, the algorithm $MPE_G$ involves two main steps: 1) we construct an underlying graph G as the Cartesian product of two graphs G1 and G2, where G1 preserves temporal information of each times series together with G2 that models the relations between different channels, and 2) we consider the multivariate signal as samples defined on the regular graph G and apply the recently introduced permutation entropy for graphs. Our graph-based approach gives the flexibility to consider diverse types of cross channel relationships and signals, and it overcomes with the limitations of current multivariate permutation entropy.

preprint2020arXiv

Consistency of Muscle Synergies Extracted via Higher-Order Tensor Decomposition Towards Myoelectric Control

In recent years, muscle synergies have been pro-posed for proportional myoelectric control. Synergies were extracted using matrix factorisation techniques (mainly non-negative matrix factorisation, NMF), which requires identification of synergies to tasks or movements. In addition, NMF methods were viable only with a task dimension of 2 degrees of freedoms(DoFs). Here, the potential use of a higher-order tensor model for myoelectric control is explored. We assess the ability of a constrained Tucker tensor decomposition to estimate consistent synergies when the task dimensionality is increased up to 3-DoFs. Synergies extracted from 3rd-order tensor of 1 and 3 DoFs were compared. Results showed that muscle synergies extracted via constrained Tucker decomposition were consistent with the increase of task-dimension. Hence, these results support the consideration of proportional 3-DoF myoelectric control based on tensor decompositions.

preprint2020arXiv

Normalised Degree Variance

Finding graph indices which are unbiased to network size and density is of high importance both within a given field and across fields for enhancing comparability of modern network science studies. The degree variance is an important metric for characterising network degree heterogeneity. Here, we provide an analytically valid normalisation of degree variance to replace previous normalisations which are either invalid or not applicable to all networks. It is shown that this normalisation provides equal values for graphs and their complements; it is maximal in the star graph (and its complement); and its expected value is constant with respect to density for Erdös-Rényi (ER) random graphs of the same size. We strengthen these results with model observations in ER random graphs, random geometric graphs, scale-free networks, random hierarchy networks and resting-state brain networks, showing that the proposed normalisation is generally less affected by both network size and density than previous normalisation attempts. The closed form expression proposed also benefits from high computational efficiency and straightforward mathematical analysis. Analysis of 184 real-world binary networks across different disciplines shows that normalised degree variance is not correlated with average degree and is robust to node and edge subsampling. Comparisons across subdomains of biological networks reveals greater degree heterogeneity among brain connectomes and food webs than in protein interaction networks.

preprint2020arXiv

On the use of higher-order tensors to model muscle synergies

The muscle synergy concept provides the best framework to understand motor control and it has been recently utilised in many applications such as prosthesis control. The current muscle synergy model relies on decomposing multi-channel surface Electromyography (EMG) signals into a synergy matrix (spatial mode) and its weighting function (temporal mode). This is done using several matrix factorisation techniques, with Non-negative matrix factorisation (NMF) being the most prominent method. Here, we introduce a 4th-order tensor muscle synergy model that extends the current state of the art by taking spectral information and repetitions (movements) into account. This adds more depth to the model and provides more synergistic information. In particular, we illustrate a proof-of-concept study where the Tucker3 tensor decomposition model was applied to a subset of wrist movements from the Ninapro database. The results showed the potential of Tucker3 tensor factorisation in finding patterns of muscle synergies with information about the movements and highlights the differences between the current and proposed model.