Source author record

Jake J. Abbott

Jake J. Abbott appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Thermal Model of an Omnimagnet for Performance Assessment and Temperature Control

An Omnimagnet is an electromagnetic device that enables remote magnetic manipulation of devices such as medical implants and microrobots. It is comprised of three orthogonal nested solenoids with a ferromagnetic core at the center. Electrical current within the solenoids leads to Joule heating, resulting in undesired temperature increase within the Omnimagnet. If the temperature exceeds the melting point of the wire insulation, device failure will occur. Thus, a study of heat transfer within an Omnimagnet is a necessity, particularly to maximize the performance of the device. For the first time, a transient heat transfer model, that incorporates all three heat transfer modes, is proposed and validated with experimental data for an Omnimagnet with maximum root mean square error equal to 8${\%}$ (4$^{\circ}$C). This transient model is not computationally expensive. It is relatively easy to apply to Omnimagnets with different structures. The accuracy of this model depends on the accuracy of the input data. The code is applied to calculate the maximum safe operational time at a fixed input current or the maximum safe input current for a fixed time interval. The maximum safe operational time and maximum safe input current depend on size and structure of the Omnimagnet and the lowest melting point of all the Omnimagnet materials. A parametric study shows that increasing convective heat transfer during cooling, and during heating with low input currents, is an effective method to increase the maximum operational time of the Omnimagnet.The thermal model is also presented in a state-space equation format that can be used in a real-time Kalman filter current controller to avoid device failure due to excessive heating.