Source author record

Fateme Esmailie

Fateme Esmailie appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Experimental validation of a three-dimensional heat transfer model within the scala tympani with application to magnetic cochlear implant surgery

Magnetic guidance of cochlear implants is a promising technique to reduce the risk of physical trauma during surgery. In this approach, a magnet attached to the tip of the implant electrode array is guided within the scala tympani using a magnetic field. After surgery, the magnet must be detached from the implant electrode array via localized heating and removed from the scala tympani which may cause thermal trauma. Objectives: The objective of this work is to experimentally validate a three-dimensional (3D) heat transfer model of the scala tympani which will enable accurate predictions of the maximum safe input power to avoid localized hyperthermia when detaching the magnet from the implant electrode array. Methods: Experiments are designed using a rigorous scale analysis and performed by measuring transient temperatures in a 3D-printed scala tympani phantom subjected to a sudden change in its thermal environment and localized heating via a small heat source. Results: The measured and predicted temperatures are in good agreement with an error less than 6$\%$. Conclusions: The validated 3D heat transfer model of the scala tympani is finally applied to evaluate the maximum safe input power to avoid localized hyperthermia when detaching the magnet. For the most conservative case where all boundaries except the insertion opening are adiabatic, the power required to release the magnet attached to the implant electrode array by 1 mm$^3$ of paraffin is approximately half of the predicted maximum safe input power. Significance: This work will enable the design of a thermally safe magnetic cochlear implant surgery procedure.

preprint2020arXiv

Heat transfer analysis in an uncoiled model of the cochlea during magnetic cochlear implant surgery

Magnetic cochlear implant surgery requires removal of a magnet via a heating process after implant insertion, which may cause thermal trauma within the ear. Intra-cochlear heat transfer analysis is required to ensure that the magnet removal phase is thermally safe. The objective of this work is to determine the safe range of input power density to detach the magnet without causing thermal trauma in the ear, and to analyze the effectiveness of natural convection with respect to conduction for removing the excess heat. A finite element model of an uncoiled cochlea, which is verified and validated, is applied to determine the range of maximum safe input power density to detach a 1-mm-long, 0.5-mm-diameter cylindrical magnet from the cochlear implant electrode array tip. It is shown that heat dissipation in the cochlea is primarily mediated by conduction through the electrode array. The electrode array simultaneously reduces natural convection due to the no-slip boundary condition on its surface and increases axial conduction in the cochlea. It is concluded that natural convection heat transfer in a cochlea during robotic cochlear implant surgery can be neglected. It is found that thermal trauma is avoided by applying a power density from $2.265 \times 10^7$ W/m$^3$ for 114 s to $6.6\times10^7$ W/m$^3$ for 9 s resulting in a maximum temperature increase of 6$^\circ$C on the magnet boundary.

preprint2020arXiv

Thermal Model of an Omnimagnet for Performance Assessment and Temperature Control

An Omnimagnet is an electromagnetic device that enables remote magnetic manipulation of devices such as medical implants and microrobots. It is comprised of three orthogonal nested solenoids with a ferromagnetic core at the center. Electrical current within the solenoids leads to Joule heating, resulting in undesired temperature increase within the Omnimagnet. If the temperature exceeds the melting point of the wire insulation, device failure will occur. Thus, a study of heat transfer within an Omnimagnet is a necessity, particularly to maximize the performance of the device. For the first time, a transient heat transfer model, that incorporates all three heat transfer modes, is proposed and validated with experimental data for an Omnimagnet with maximum root mean square error equal to 8${\%}$ (4$^{\circ}$C). This transient model is not computationally expensive. It is relatively easy to apply to Omnimagnets with different structures. The accuracy of this model depends on the accuracy of the input data. The code is applied to calculate the maximum safe operational time at a fixed input current or the maximum safe input current for a fixed time interval. The maximum safe operational time and maximum safe input current depend on size and structure of the Omnimagnet and the lowest melting point of all the Omnimagnet materials. A parametric study shows that increasing convective heat transfer during cooling, and during heating with low input currents, is an effective method to increase the maximum operational time of the Omnimagnet.The thermal model is also presented in a state-space equation format that can be used in a real-time Kalman filter current controller to avoid device failure due to excessive heating.