Source author record

J. Wenz

J. Wenz appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Dual-energy electron beams from a compact laser-driven accelerator

Ultrafast pump-probe experiments open the possibility to track fundamental material behaviour like changes in its electronic configuration in real time. To date, most of these experiments are performed using an electron or a high-energy photon beam, which is synchronized to an infrared laser pulse. Entirely new opportunities can be explored if not only a single, but multiple synchronized, ultra-short, high-energy beams are used. However, this requires advanced radiation sources that are capable of producing dual-energy electron beams, for example. Here, we demonstrate simultaneous generation of twin-electron beams from a single compact laser wakefield accelerator. The energy of each beam can be individually adjusted over a wide range and our analysis shows that the bunch lengths and their delay inherently amount to femtoseconds. Our proof-of-concept results demonstrate an elegant way to perform multi-beam experiments in future on a laboratory scale.

preprint2014arXiv

Temporal evolution of longitudinal bunch profile in a laser wakefield accelerator

Due to their ultra-short duration and peak currents in the kA range, laser-wakefield accelerated electron bunches are promising drivers for ultrafast X-ray generation in compact free-electron-lasers (FELs), Thomson-scattering or betatron sources. Here we present the first single-shot, high-resolution measurements of the longitudinal bunch profile obtained without prior assumptions about the bunch shape. Our method allows complex features, such as multi-bunch structures, to be detected. Varying the length of the gas target, and thus the acceleration length, enables an assessment of the bunch profile evolution during the acceleration process. We find a minimum bunch duration of 4.2 fs (full width at half maximum) with shot-to-shot fluctuation of 11% rms. Our results suggest that after depletion of the laser energy, a transition from a laser-driven to a particle-driven wakefield occurs, associated with the injection of a secondary bunch. The resulting double-bunch structure might act as an elegant approach for driver-witness type experiments, i.e. allowing a non-dephasing-limited acceleration of the secondary bunch in a plasma-afterburner stage.

preprint2014arXiv

Tunable, all-optical quasi-monochromatic Thomson X-ray source

Brilliant X-ray sources are of great interest for many research fields from biology via medicine to material research. The quest for a cost-effective, brilliant source with unprecedented temporal resolution has led to the recent realization of various high-intensity-laser-driven X-ray beam sources. Here we demonstrate the first all-laser-driven, energy-tunable and quasi-monochromatic X-ray source based on Thomson backscattering. This is a decisive step beyond previous results, where the emitted radiation exhibited an uncontrolled broad energy distribution. In the experiment, one part of the laser beam was used to drive a few-fs bunch of quasi-monoenergetic electrons from a Laser-Wakefield Accelerator (LWFA), while the remainder was scattered off the bunch in a near-counter-propagating geometry. When the electron energy was tuned from 10-50 MeV, narrow-bandwidth X-ray spectra peaking at 5-35keV were directly measured, limited in photon energy by the sensitivity curve of our X-ray detector. Due to the ultrashort LWFA electron bunches, these beams exhibit few-fs pulse duration.