Researcher profile

J. I. Collar

J. I. Collar contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Comments on "Direct measurement of the ionization quenching factor of nuclear recoils in germanium in the keV energy range"

We examine a recent measurement of the quenching factor (QF) in germanium at 80 K, noticing a number of inconsistencies capable of affecting a claimed agreement with Lindhard's ion-stopping formalism in the sub-keV nuclear recoil energy regime. Namely, an underestimated uncertainty in the energy scale and a missing correction for a large instrumental non-linearity in this scale able to severely distort the QF behavior at low energy, favoring reduced values. The discussion is expanded to inspect the impact of QF model selection on a study of neutrino electromagnetic properties using CE$ν$NS data that supports a non-zero electric charge at the 3.5 $σ$ level.

preprint2022arXiv

Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

preprint2020arXiv

Coherent Elastic Neutrino-Nucleus Scattering at the European Spallation Source

The European Spallation Source (ESS), presently well on its way to completion, will soon provide the most intense neutron beams for multi-disciplinary science. Fortuitously, it will also generate the largest pulsed neutrino flux suitable for the detection of Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS), a process recently measured for the first time at ORNL's Spallation Neutron Source. We describe innovative detector technologies maximally able to profit from the order-of-magnitude increase in neutrino flux provided by the ESS, along with their sensitivity to a rich particle physics phenomenology accessible through high-statistics, precision CE$ν$NS measurements.

preprint2019arXiv

Dark Matter-Electron Scattering from Aromatic Organic Targets

Sub-GeV dark matter (DM) which interacts with electrons can excite electrons occupying molecular orbitals in a scattering event. In particular, aromatic compounds such as benzene or xylene have an electronic excitation energy of a few eV, making them sensitive to DM as light as a few MeV. These compounds are often used as solvents in organic scintillators, where the de-excitation process leads to a photon which propagates until it is absorbed and re-emitted by a dilute fluor. The fluor photoemission is not absorbed by the bulk, but is instead detected by a photon detector such as a photomultiplier tube. We develop the formalism for DM-electron scattering in aromatic organic molecules, calculate the expected rate in p-xylene, and apply this calculation to an existing measurement of the single photo-electron emission rate in a low-background EJ-301 scintillator cell. Despite the fact that this measurement was performed in a shallow underground laboratory under minimal overburden, the DM-electron scattering limits extracted from these data are already approaching leading constraints in the 3-100 MeV DM mass range. We discuss possible next steps in the evolution of this direct detection technique, in which scalable organic scintillators are used in solid or liquid crystal phases and in conjunction with semiconductor photodetectors to improve sensitivity through directional signal information and potentially lower dark rates.