Source author record

J. D. Parker

J. D. Parker appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2016arXiv

Interference effect between $ϕ$ and $Λ(1520)$ production channels in the $γp \rightarrow K^+K^-p$ reaction near threshold

The $ϕ$-$Λ(1520)$ interference effect in the $γp\to K^+K^-p$ reaction has been measured for the first time in the energy range from 1.673 to 2.173 GeV. The relative phases between $ϕ$ and $Λ(1520)$ production amplitudes were obtained in the kinematic region where the two resonances overlap. The measurement results support strong constructive interference when $K^+K^-$ pairs are observed at forward angles, but destructive interference for proton emission at forward angles. Furthermore, the observed interference effect does not account for the $\sqrt{s}=2.1$ GeV bump structure in forward differential cross sections for $ϕ$ photoproduction. This fact suggests possible exotic structures such as a hidden-strangeness pentaquark state, a new Pomeron exchange and rescattering processes via other hyperon states.

preprint2016arXiv

Readout technologies for directional WIMP Dark Matter detection

The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

preprint2015arXiv

An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays

Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.

preprint2015arXiv

Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam

We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.

preprint2014arXiv

Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment

To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.

preprint2013arXiv

Backward-angle photoproduction of $ω$ and $η'$ mesons from protons at $E_γ=1.5-3.0$ GeV

We report the measurement of differential cross sections for $ω$ and $η'$ photoproduction from protons at backward angles ($-1.0<\cosΘ_{C.M}^{X}<-0.8$) using linearly polarized photons at $E_γ=$$1.5-3.0$ GeV. Differential cross sections for $ω$ mesons are larger than the predicted $u$-channel contribution in the energy range $2.0\leq\sqrt{s}\leq2.4$ GeV. The differential cross sections for $ω$ and $η'$ mesons become closer to the predicted $u$-channel contribution at $\sqrt{s}>2.4$ GeV. A bump structure in the $\sqrt{s}$ dependence of the differential cross sections for $η'$ mesons was observed at $\sqrt{s}\sim$2.35 GeV.

preprint2013arXiv

Search for $K^-pp$ bound state via $γd \rightarrow K^+ π^-X$ reaction at $E_γ=1.5-2.4$ GeV

A search for $K^-pp$ bound state (the lightest kaonic nucleus) has been performed using the $γd \rightarrow K^+ π^- \rm{X}$ reaction at E$_γ$=1.5-2.4 GeV at LEPS/SPring-8. The differential cross section of $K^+ π^-$ photo-production off deuterium has been measured for the first time in this energy region, and a bump structure was searched for in the inclusive missing mass spectrum. A statistically significant bump structure was not observed in the region from 2.22 to 2.36 GeV/$c^2$, and the upper limits of the differential cross section for the $K^-pp$ bound state production were determined to be 0.1$-$0.7 $μ$ b (95$%$ confidence level) for a set of assumed binding energy and width values.

preprint2012arXiv

Neutron imaging detector based on the muPIC micro-pixel chamber

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.

preprint2007arXiv

Weak decays of 4He-Lambda

We measured the lifetime and the mesonic and non-mesonic decay rates of the 4He-Lambda hypernucleus. The hypernuclei were created using a 750 MeV/c momentum K- beam on a liquid 4He target by the reaction 4He(K-,pi-)4He-Lambda. The 4He-Lambda lifetime was directly measured using protons from Lambda p -> n p non-mesonic decay (also referred to as proton-stimulated decay) and was found to have a value of tau = 245 +/- 24 ps. The mesonic decay rates were determined from the observed numbers of pi-'s and pi0's as Gamma_pi-/Gamma_tot = 0.270 +/- 0.024 and Gamma_pi0/Gamma_tot = 0.564 +/- 0.036, respectively, and the values of the proton- and neutron-stimulated decay rates were extracted as Gamma_p/Gamma_tot = 0.169 +/- 0.019 and Gamma_n/Gamma_tot <= 0.032 (95% CL), respectively. The effects of final-state interactions and possible 3-body Lambda N N decay contributions were studied in the context of a simple model of nucleon-stimulated decay. Nucleon-nucleon coincidence events were observed and were used in the determination of the non-mesonic branching fractions. The implications of the results of this analysis were considered for the empirical Delta I = 1/2 rule and the decay rates of the 4H-Lambda hypernucleus.