Source author record

J. Corbett

J. Corbett appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.

preprint2022arXiv

Effective Field Theory Analysis of CDMSlite Run 2 Data

CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.

preprint2021arXiv

Constraints on dark photons and axion-like particles from SuperCDMS Soudan

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

preprint2021arXiv

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.

preprint2011arXiv

Modal noise prediction in fibre-spectroscopy I: Visibility and the coherent model

Fibre modal noise occurs in high spectral resolution, high signal-to-noise applications. It imposes fundamental limits on the photometric accuracy of state-of-the-art fibre-spectrograph systems. In order to maximize the performance of current and future instruments it is therefore essential to predict fibre modal noise. To attain a predictive model we are using a dual approach, bringing theoretical assumptions in line with the experimental data obtained using a test-bench spectrograph. We show that the task of noise prediction can be reduced to determining the visibility of the modal pattern which can be measured at the detector plane. Subsequently, the visibility-dependence of essential parameters is presented. This work will soon provide a basis for prediction of modal noise limitations in fibre-coupled spectrograph designs.

preprint2001arXiv

Dynamic Aperture Studies for SPEAR 3

The Stanford Synchrotron Radiation Laboratory is investigating an accelerator upgrade project that would replace the present 130 nm rad FODO lattice with an 18 nm rad double bend achromat (DBA) lattice: SPEAR 3. The low emittance design yields a high brightness beam, but the stronger focusing in the DBA lattice increases chromaticity and beam sensitivity to machine errors. To ensure efficient injection and long Touschek lifetime, an optimization of the design lattice and dynamic aperture has been performed. In this paper, we review the methods used to maximize the SPEAR 3 dynamic aperture including necessary optics modifications, choice of tune and phase advance, optimization of sextupole and coupling correction, and modeling effects of machine errors, wigglers and lattice periodicity.