Researcher profile

Ignacio O. Romero

Ignacio O. Romero contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
1topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

A feasibility Study of Time of Flight Computed Tomography for Breast Imaging

Cone beam computed tomography (CBCT) for breast imaging has potential to replace conventional mammograms. However, concerns over dose and image quality prevent CBBCT systems from the clinical trial phase to next stage. The time of flight (TOF) method was recently shown to reduce the x-ray scattering effects by 95% and improve the image CNR by 110% for large volume objects. The advancements in x-ray sources like in compact Free Electron Lasers (FEL) and advancements in detector technology show potential for the TOF method to be feasible in CBCT when imaging large objects. In this study, we investigate the efficacy of this TOF CBCT in improving the breast cancer imaging. The GATE software was used to simulate the cone beam CT imaging of an 8 cm diameter cylindrical water phantom using a modeled 20 keV quasi-energetic FEL source and various detector temporal resolutions ranging from 1 to 1000 ps. An inhomogeneous breast phantom of similar size was also imaged using the same system setup. Results show that a detector temporal resolution of 10 ps improved the image contrast-to-noise ratio (CNR) by 57% and reduced the scatter-to-primary ratio (SPR) by 8.63 for a small cylindrical phantom. For the breast phantom, the image CNR was enhanced by 12% and the SPR was reduced by 1.35 at 5 ps temporal resolution.

preprint2021arXiv

Radiation dose estimation in pencil beam x-ray luminescence computed tomography imaging

Pencil x-ray beam imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries due to the illumination of a line instead of an area or volume. However, the pencil beam geometry suffers from long scan times and concerns over dose discourage laboratory use of pencil beam x-ray sources. Molecular imaging techniques like XLCT imaging benefit most from pencil beam imaging to accurately localize the distribution of contrast agents embedded in a small animal object. To investigate the dose deposited by pencil beam x-ray imaging in XLCT, dose estimations from one angular projection scan by three different x-ray source energies were performed on a small animal object composed of water, bone, and blood with a Monte Carlo simulation platform, GATE (Geant4 Application for Tomographic Emission). Our results indicate that, with an adequate x-ray benchtop source with high brilliance and quasi-monochromatic properties like the Sigray source, the dose concerns can be reduced. With the Sigray source, the bone marrow was estimated to have a radiation dose of 30 mGy for a typical XLCT imaging, in which we have 6 angular projections, 100 micrometer scan step size, and 10^6 x-ray photons per linear scan.

preprint2021arXiv

X-ray fluorescence computed tomography (XFCT) imaging with a superfine pencil beam x-ray source

X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique of x-ray photons, which can be used to sense different elements or nanoparticle (NP) agents inside deep samples or tissues. XFCT has been an active research topic for many years. However, XFCT has not been a popular molecular imaging tool because it has limited molecular sensitivity and spatial resolution. To further investigate XFCT imaging, we present a benchtop XFCT imaging system, in in which a unique pencil beam x-ray source and a ring of x-ray spectrometers were simulated using GATE (Geant4 Application for Tomographic Emission) software. An accelerated majorization minimization (MM) algorithm with an L1 regularization scheme was used to reconstruct the XRF image of Molybdenum (Mo) NP targets from the numerical measurements of GATE simulations. With a low x-ray source output rate, good target localization was achieved with a DICE coefficient of 83.681%. The reconstructed signal intensity of the targets was found to be relatively proportional to the target concentrations if detector number and placement is optimized. The MM algorithm performance was compared with maximum likelihood expectation maximization (ML-EM) and filtered back projection (FBP) algorithms. In the future, the benchtop XFCT imaging system will be tested experimentally