Researcher profile

I. Israelashvili

I. Israelashvili contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2019arXiv

First results of Resistive-Plate Well (RPWELL) detector operation at 163 K

We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk resistivity. The results of single- and double-stage RPWELL detectors operated in stable conditions in Ne/5$\%$CH$_{4}$ at 163 K are summarized. The RPWELL comprised a ferric-based (Fe$^{3+}$) ceramic composite ("Fe-ceramic") as the resistive plate, of volume resistivity $\sim$$10^{11}$ $Ω$$\cdot$cm at this temperature. Gains of $\sim$$10^{4}$ and $\sim$$10^{5}$ were reached with the single-stage RPWELL, with 6 keV X-rays and single UV-photons, respectively. The double-stage detector, a THGEM followed by the RPWELL, reached gains $\sim$$10^{5}$ and $\sim$$10^{6}$ with X-rays and single UV-photons, respectively. The results were obtained with and without a CsI photocathode on the first multiplying element. Potential applications at these cryogenic conditions are discussed.

preprint2016arXiv

Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography

A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.

preprint2015arXiv

First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC

We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signals. The detector comprised a triple Thick Gas Electron Multiplier (THGEM) structure with cesium iodide photocathode on the first element; it was shown to operate stably at 180 K with gains above 10^5, providing high single-photon detection efficiency even in the presence of large alpha particle-induced S2 signals comprising thousands of photoelectrons. S1 scintillation signals were recorded with a time resolution of 1.2 ns (RMS). The energy resolution (σ/E) for S2 electroluminescence of 5.5 MeV alpha particles was ~9%, which is comparable to that obtained in the XENON100 TPC with PMTs. The results are discussed within the context of potential GPM deployment in future multi-ton noble-liquid detectors.

preprint2014arXiv

A Comprehensive Simulation Study of a Liquid-Xe Detector for Contraband Detection

Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the type and performance of LXe converter. We have evaluated the detector spectral response, detection efficiency and spatial resolution for gamma-rays and neutrons in the energy range of 2-15 MeV for 50 mm thick converters consisting of plain LXe volume and LXe-filled capillaries, of Teflon, Polyethylene or hydrogen-containing Teflon (Tefzel). Neutron detection efficiencies for plain LXe, Teflon-capillaries and Tefzel-capillaries converters were about 20% over the entire energy range. In polyethylene capillaries converters the neutron detection efficiency was about 10% at 2 MeV and increased up to about 20% at 14 MeV. Detection efficiencies of gammas in Teflon, Tefzel and polyethylene converters were ~35%. The plain-LXe converter provided the highest gamma-ray detection efficiency, of ~40-50% for 2-15 MeV energy range. Optimization of LXe-filled Tefzel capillary dimensions resulted in spatial resolution of ~1.5mm (FWHM) for neutrons and up to 3.5 mm (FWHM) for gamma-rays. Simulations of radiographic images of various materials using two discrete energy gamma-rays (4.4 MeV and 15.1 MeV) and neutrons in broad energy range (2-10 MeV) were performed in order to evaluate the potential of elemental discrimination.