Researcher profile

I. D. Moore

I. D. Moore contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
11works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Direct determination of the atomic mass difference of the pairs $^{76}$As-$^{76}$Se and $^{155}$Tb-$^{155}$Gd rules out $^{76}$As and $^{155}$Tb as possible candidates for electron (anti)neutrino mass measurements

The first direct determination of the ground-state-to-ground-state $Q$ values of the $β^-$ decay $^{76}$As $\rightarrow$ $^{76}$Se and the electron-capture decay $^{155}$Tb $\rightarrow$ $^{155}$Gd was performed utilizing the double Penning trap mass spectrometer JYFLTRAP. By measuring the atomic mass difference of the decay pairs via the phase-imaging ion-cyclotron-resonance (PI-ICR) technique, the $Q$ values of $^{76}$As $\rightarrow$ $^{76}$Se and $^{155}$Tb $\rightarrow$ $^{155}$Gd were determined to be 2959.265(74) keV and 814.94(18) keV, respectively. The precision was increased relative to earlier measurements by factors of 12 and 57, respectively. The new $Q$ values are 1.33 keV and 5 keV lower compared to the values adopted in the most recent Atomic Mass Evaluation 2020. With the newly determined ground-state-to-ground-state $Q$ values combined with the excitation energy from $γ$-ray spectroscopy, the $Q$ values for ground-state-to-excited-state transitions $^{76}$As (ground state) $\rightarrow$ $^{76}$Se$^*$ (2968.4(7) keV) and $^{155}$Tb (ground state) $\rightarrow$ $^{155}$Gd$^*$ (815.731(3) keV) were derived to be -9.13(70) keV and -0.79(18) keV. Thus we have confirmed that both of the $β^{-}$-decay and EC-decay candidate transitions are energetically forbidden at a level of at least 4$σ$, thus definitely excluding these two cases from the list of potential candidates for the search of low-$Q$-value $β^-$ or EC decays to determine the electron-(anti)neutrino mass.

preprint2022arXiv

High-precision electron-capture $Q$ value measurement of $^{111}$In for electron-neutrino mass determination

A precise determination of the ground state $^{111}$In ($9/2^+$) electron capture to ground state of $^{111}$Cd ($1/2^+$) $Q$ value has been performed utilizing the double Penning trap mass spectrometer, JYFLTRAP. A value of 857.63(17) keV was obtained, which is nearly a factor of 20 more precise than the value extracted from the Atomic Mass Evaluation 2020 (AME2020). The high-precision electron-capture $Q$ value measurement along with the nuclear energy level data of 866.60(6) keV, 864.8(3) keV, 855.6(10) keV, and 853.94(7) keV for $^{111}$Cd was used to determine whether the four states are energetically allowed for a potential ultra-low $Q$-value $β^{}$ decay or electron-capture decay. Our results confirm that the excited states of 866.60(6) keV with spin-parity ($J^π$) of 3/2$^{+}$ and 864.8(3) keV with $J^π$ = 3/2$^{+}$ are ruled out due to their deduced electron-capture $Q$ value being smaller than 0 keV at the level of around 20$σ$ and 50$σ$, respectively. Electron-capture decays to the excited states at 853.94(7) keV ($J^π$ = 7/2$^+$) and 855.6(10) keV ($J^π$ = 3/2$^+$), are energetically allowed with $Q$ values of 3.69(19) keV and 2.0(10) keV, respectively. The allowed decay transition $^{111}$In (9/2$^{+}$) $\rightarrow$ $^{111}$Cd (7/2$^{+}$), with a $Q$ value of 3.69(19) keV, is a potential a new candidate for neutrino-mass measurements by future EC experiments featuring new powerful detection technologies. The results show that the indium level $2p_{1/2}$ for this decay branch leads to a significant increase in the number of EC events in the energy region sensitive to the electron neutrino mass.

preprint2021arXiv

$^{159}$Dy electron-capture: a strong new candidate for neutrino mass determination

{ The ground-state to ground-state electron-capture $Q$ value of $^{159}$Dy ($3/2^-$) has been measured directly utilizing the double Penning trap mass spectrometer JYFLTRAP. A value of 364.73(19)~keV was obtained from a measurement of the cyclotron frequency ratio of the decay parent $^{159}$Dy and the decay daughter $^{159}$Tb ions using the novel phase-imaging ion-cyclotron resonance technique. The $Q$ values for allowed Gamow-Teller transition to $5/2^-$ and the third-forbidden unique transition to $11/2^+$ state with excitation energies of 363.5449(14)~keV and 362.050(40)~keV in $^{159}$Tb were determined to be 1.18(19) keV and 2.68(19) keV, respectively. The high-precision $Q$ value of transition $3/2^-\to 5/2^-$ from this work, revealing itself as the lowest electron-capture $Q$ value, is utilized to unambiguously characterise all the possible lines that are present in its electron capture spectrum. { We performed atomic many-body calculations for both transitions to determine electron-capture probabilities from various atomic orbitals, and found an order of magnitude enhancement in the event rates near the end-point of energy spectrum in the transition to the $5/2^-$ nuclear excited state, which can become very interesting once the experimental challenges of identifying decays into excited states are overcome. The transition to the $11/2^+$ state is strongly suppressed and found unsuitable for measuring the neutrino mass. These results show that the electron capture in the $^{159}$Dy atom, going to the $5/2^-$ state of the $^{159}$Tb nucleus, %\textcolor{red} {is a new candidate which may open the way to determine the electron-neutrino mass in the sub-eV region by studying EC. Further experimental feasibility studies, including coincidence measurements with realistic detectors, will be of great interest.} }

preprint2020arXiv

Determination of Beta Decay Ground State Feeding of Nuclei of Importance for Reactor Applications

In $β$-decay studies the determination of the decay probability to the ground state of the daughter nucleus often suffers from large systematic errors. The difficulty of the measurement is related to the absence of associated delayed $γ$-ray emission. In this work we revisit the $4πγ-β$ method proposed by Greenwood and collaborators in the 1990s, which has the potential to overcome some of the experimental difficulties. Our interest is driven by the need to determine accurately the $β$-intensity distributions of fission products that contribute significantly to the reactor decay heat and to the antineutrinos emitted by reactors. A number of such decays have large ground state branches. The method is relevant for nuclear structure studies as well. Pertinent formulae are revised and extended to the special case of $β$-delayed neutron emitters, and the robustness of the method is demonstrated with synthetic data. We apply it to a number of measured decays that serve as test cases and discuss the features of the method. Finally, we obtain ground state feeding intensities with reduced uncertainty for four relevant decays that will allow future improvements in antineutrino spectrum and decay heat calculations using the summation method.

preprint2020arXiv

High-precision $Q$-value measurement confirms the potential of $^{135}$Cs for antineutrino-mass detection

The ground-state-to-ground-state $β$-decay $Q$-value of $^{135}\textrm{Cs}(7/2^+)\to\,^{135}\textrm{Ba}(3/2^+)$ was directly measured for the first time utilizing the Phase-Imaging Ion-Cyclotron Resonance (PI-ICR) technique at the JYFLTRAP Penning-trap setup. It is the first direct determination of this $Q$-value and its value of 268.66(30)\,keV is a factor of three more precise than the currently adopted $Q$-value in the Atomic Mass Evaluation 2016. Moreover, the $Q$-value deduced from the $β$-decay endpoint energy has been found to deviate from our result by approximately 6 standard deviations. The measurement confirms that the first-forbidden unique $β^-$-decay transition $^{135}\textrm{Cs}(7/2^+)\to\,^{135}\textrm{Ba}(11/2^-)$ is a candidate for antineutrino-mass measurements with an ultra-low $Q$-value of $0.44(31)$ keV. This $Q$-value is almost an order of magnitude smaller than in any presently running or planned direct (anti)neutrino-mass experiment.

preprint2020arXiv

Novel Penning-trap techniques reveal isomeric states in $^{128}$In and $^{130}$In for the first time

Isomeric states in $^{128}$In and $^{130}$In have been studied with the JYFLTRAP Penning trap at the IGISOL facility. By employing novel ion manipulation techniques, different states were separated and masses of six beta-decaying states were measured. JYFLTRAP was also used to select the ions of interest for identification at a post-trap decay spectroscopy station. A new beta-decaying high-spin isomer feeding the $15^-$ isomer in $^{128}$Sn has been discovered in $^{128}$In at $1797.6(20)$ keV. Shell-model calculations employing a CD-Bonn potential re-normalized with the perturbative G-matrix approach suggest this new isomer to be a $16^+$ spin-trap isomer. In $^{130}$In, the lowest-lying $(10^-)$ isomeric state at $58.6(82)$ keV was resolved for the first time using the phase-imaging ion cyclotron resonance technique. The energy difference between the $10^-$ and $1^-$ states in $^{130}$In, stemming from parallel/antiparallel coupling of $(π0g_{9/2}^{-1})\otimes(ν0h_{11/2}^{-1})$, has been found to be around 200 keV lower than predicted by the shell model. Precise information on the energies of the excited states determined in this work is crucial for producing new improved effective interactions for the nuclear shell model description of nuclei near $^{132}$Sn.

preprint2020arXiv

Self-consistent tomography and measurement-device independent cryptography

A recurring problem in quantum mechanics is to estimate either the state of a quantum system or the measurement operator applied to it. If we wish to estimate both, then the difficulty is that the state and the measurement always appear together: to estimate the state, we must use a measurement; to estimate the measurement operator, we must use a state. The data of such quantum estimation experiments come in the form of measurement frequencies. Ideally, the measured average frequencies can be attributed to an average state and an average measurement operator. If this is not the case, we have correlated state-preparation-and-measurement (SPAM) errors. We extend some tests developed to detect such correlated errors to apply to a cryptographic scenario in which two parties trust their individual states but not the measurement performed on the joint state.

preprint2019arXiv

A new off-line ion source facility at IGISOL

An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap mass measurements, laser spectroscopy and atom trap experiments.

preprint2019arXiv

Characterization of $^{233}$U alpha recoil sources for $^{229(m)}$Th beam production

Radioactive $^{233}$U alpha recoil sources are being considered for the production of a thorium ion source to study the low-energy isomer in $^{229}$Th with high-resolution collinear laser spectroscopy at the IGISOL facility of the University of Jyväskylä. In this work two different $^{233}$U sources have been characterized via alpha and gamma spectroscopy of the decay radiation obtained directly from the sources and from alpha-recoils embedded in implantation foils. These measurements revealed rather low $^{229}$Th recoil efficiencies of only a few percent. Although the low efficiency of one of the two sources can be attributed to its inherent thickness, the low recoil efficiency of the second, thinner source, was unexpected. Rutherford backscattering spectrometry (RBS) was performed to investigate the elemental composition as a function of depth revealing a contamination layer on top of the thin source. The combination of spectroscopic methods proves to be a useful approach in the assessment of alpha recoil source performance in general.

preprint2019arXiv

Exploring the mass surface near the rare-earth abundance peak via precision mass measurements at JYFLTRAP

The JYFLTRAP double Penning trap at the Ion Guide Isotope Separator On-Line (IGISOL) facility has been used to measure the atomic masses of 13 neutron-rich rare-earth isotopes. Eight of the nuclides, $^{161}$Pm, $^{163}$Sm, $^{164,165}$Eu, $^{167}$Gd, and $^{165,167,168}$Tb, were measured for the first time. The systematics of the mass surface has been studied via one- and two-neutron separation energies as well as neutron pairing-gap and shell-gap energies. The proton-neutron pairing strength has also been investigated. The impact of the new mass values on the astrophysical rapid neutron capture process has been studied. The calculated abundance distribution results in a better agreement with the solar abundance pattern near the top of the rare-earth abundance peak at around $A\approx165$.

preprint2008arXiv

A Hot Cavity Laser Ion Source at IGISOL

A development program is underway at the IGISOL (Ion Guide Isotope Separator On-Line) facility, University of Jyvaskyla, to efficiently and selectively produce low-energy radioactive ion beams of silver isotopes and isomers, with a particular interest in N=Z 94Ag. A hot cavity ion source has been installed, based on the FEBIAD (Forced Electron Beam Induced Arc Discharge) technique, combined with a titanium:sapphire laser system for selective laser ionization. The silver recoils produced via the heavy-ion fusion-evaporation reaction, 40Ca(58Ni, p3n)94Ag, are stopped in a graphite catcher, diffused, extracted and subsequently ionized using a three-step laser ionization scheme. The performance of the different components of the hot cavity laser ion source is discussed and initial results using stable 107,109Ag are presented.