Researcher profile

I. A. Vartanyants

I. A. Vartanyants contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
19works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

19 published item(s)

preprint2021arXiv

Structural Study of a Self-Assembled Gold Mesocrystal Grain by Coherent X-ray Diffraction Imaging

Mesocrystals are nanostructured materials consisting of individual nanocrystals having a preferred crystallographic orientation. On mesoscopic length scales, the properties of mesocrystals are strongly affected by structural heterogeneity. Here, we report the detailed structural characterization of a faceted mesocrystal grain self-assembled from 60 nm sized gold nanocubes. Using coherent X-ray diffraction imaging, we determined the structure of the mesocrystal with the resolution sufficient to resolve each gold nanoparticle. The reconstructed electron density of the gold mesocrystal reveals its intrinsic structural heterogeneity, including local deviations of lattice parameters, and the presence of internal defects. The strain distribution shows that the average superlattice obtained by angular X-ray cross-correlation analysis and the real, multidomain structure of a mesocrystal are very close to each other, with a deviation less than 10 percent. These results will provide an important impact to understanding of the fundamental principles of structuring and self-assembly including ensuing properties of mesocrystals.

preprint2014arXiv

Characterization of Spatial Coherence of Synchrotron Radiation with Non-Redundant Arrays of Apertures

We present a method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern. The technique is based on scattering from non-redundant arrays (NRA) of slits and records the degree of spatial coherence at several relative separations from one to 15 microns, simultaneously. Using NRAs we measured the transverse coherence of the X-ray beam at the XUV X-ray beamline P04 of the PETRA III synchrotron storage ring as a function of different beam parameters. To verify the results obtained with the NRAs additional Young's double pinhole experiments were conducted and show good agreement.

preprint2014arXiv

Intensity interferometry of single x-ray pulses from a synchrotron storage ring

We report on measurements of second-order intensity correlations at the high brilliance storage ring PETRA III using a prototype of the newly developed Adaptive Gain Integrating Pixel Detector (AGIPD). The detector recorded individual synchrotron radiation pulses with an x-ray photon energy of 14.4 keV and repetition rate of about 5 MHz. The second-order intensity correlation function was measured simultaneously at different spatial separations that allowed to determine the transverse coherence length at these x-ray energies. The measured values are in a good agreement with theoretical simulations based on the Gaussian Schell-model.

preprint2014arXiv

Spatially resolved x-ray studies of liquid crystals with strongly developed bond-orientational order

We present an x-ray study of freely suspended hexatic films of the liquid crystal 3(10)OBC. Our results reveal spatial inhomogeneities of the bond-orientational (BO) order in the vicinity of the hexatic-smectic phase transition and the formation of large scale hexatic domains at lower temperatures. Deep in the hexatic phase up to 25 successive sixfold BO order parameters have been directly determined by means of angular x-ray cross-correlation analysis (XCCA). Such strongly developed hexatic order allowed us to determine higher order correction terms in the scaling relation predicted by the multicritical scaling theory over a full temperature range of the hexatic phase existence.

preprint2013arXiv

Coherence properties of focused X-ray beams at high brilliance synchrotron sources

An analytical approach describing properties of focused partially coherent X-ray beams is presented. The method is based on the results of statistical optics and gives both the beam size and transverse coherence length at any distance behind an optical element. In particular, here we consider Gaussian Schell-model beams and thin optical elements. Limiting cases of incoherent and fully coherent illumination of the focusing element are discussed. The effect of the beam defining aperture, typically used in combination with focusing elements at synchrotron sources to improve transverse coherence, is also analyzed in detail. As an example the coherence properties in the focal region of compound refractive lenses at the PETRA III synchrotron source are analyzed.

preprint2013arXiv

Hanbury Brown and Twiss interferometry at a free-electron laser

We present measurements of second- and higher-order intensity correlation functions (so-called Hanbury Brown and Twiss experiment) performed at the free-electron laser (FEL) FLASH in the non-linear regime of its operation. We demonstrate the high transverse coherence properties of the FEL beam with a degree of transverse coherence of about 80% and degeneracy parameter of the order 10^9 that makes it similar to laser sources. Intensity correlation measurements in spatial and frequency domain gave an estimate of the FEL average pulse duration of 50 fs. Our measurements of the higher-order correlation functions indicate that FEL radiation obeys Gaussian statistics, which is characteristic to chaotic sources.

preprint2013arXiv

Orientation Determination in Single Particle X-ray Coherent Diffraction Imaging Experiments

Single particle diffraction imaging experiments at free-electron lasers (FEL) have a great potential for structure determination of reproducible biological specimens that can not be crystallized. One of the challenges in processing the data from such an experiment is to determine correct orientation of each diffraction pattern from samples randomly injected in the FEL beam. We propose an algorithm (see also O. Yefanov et al., Photon Science - HASYLAB Annual Report 2010) that can solve this problem and can be applied to samples from tens of nanometers to microns in size, measured with sub-nanometer resolution in the presence of noise. This is achieved by the simultaneous analysis of a large number of diffraction patterns corresponding to different orientations of the particles. The algorithms efficiency is demonstrated for two biological samples, an artificial protein structure without any symmetry and a virus with icosahedral symmetry. Both structures are few tens of nanometers in size and consist of more than 100 000 non-hydrogen atoms. More than 10 000 diffraction patterns with Poisson noise were simulated and analyzed for each structure. Our simulations indicate the possibility to achieve resolution of about 3.3 Å at 3 Å wavelength and incoming flux of 10^{12} photons per pulse focused to 100\times 100 nm^2.

preprint2013arXiv

Ptychography imaging of the phase vortices in the x-ray beam formed by nanofocusing lenses

We present the ptychography reconstruction of the x-ray beam formed by nanofocusing lenses (NFLs) containing a number of phase singularities (vortices) in the vicinity of the focal plane. As a test object Siemens star pattern was used with the finest features of 50 nm for ptychography measurements. The extended ptychography iterative engine (ePIE) algorithm was applied to retrieve both complex illumination and object functions from the set of diffraction patterns. The reconstruction revealed the focus size of 91.4$\pm$1.1 nm in horizontal and 70$\pm$0.3 nm in vertical direction at full width at half maximum (FWHM). The complex probe function was propagated along the optical axis of the beam revealing the evolution of the phase singularities.

preprint2013arXiv

Spatial properties of $π-π$ conjugated network in semicrystalline polymer thin films studied by intensity x-ray cross-correlation functions

We present results of x-ray study of spatial properties of $π-π$ conjugated networks in polymer thin films. We applied the x-ray cross-correlation analysis to x-ray scattering data from blends of poly(3-hexylthiophene) (P3HT) and gold nanoparticles. The Fourier spectra of the intensity cross-correlation functions for different films contain non-zero components of orders $n=2,4$ and $6$ measuring the degree of structural order in the system.

preprint2013arXiv

X-ray cross-correlation analysis of disordered systems: potentials and limitations

Angular x-ray cross-correlation analysis (XCCA) is an approach to study the structure of disordered systems using the results of x-ray scattering experiments. In this paper we summarize recent theoretical developments related to the Fourier analysis of the cross-correlation functions. Results of our simulations demonstrate the application of XCCA to two- and three-dimensional (2D and 3D) disordered systems of particles. We show that the structure of a single particle can be recovered using x-ray data collected from a 2D disordered system of identical particles. We also demonstrate that valuable structural information about the local structure of 3D systems, inaccessible from a standard small-angle x-ray scattering experiment, can be resolved using XCCA.

preprint2013arXiv

X-ray cross-correlation analysis of liquid crystal membranes in the vicinity of hexatic-smectic phase transition

We present an x-ray study of liquid crystal membranes in the vicinity of hexatic-smectic phase transition by means of angular x-ray cross-correlation analysis (XCCA). By applying two-point angular intensity cross-correlation functions to the measured series of diffraction patterns the parameters of bond-orientational (BO) order in hexatic phase were directly determined. The temperature dependence of the positional correlation lengths was analyzed as well. The obtained correlation lengths show larger values for the higher-order Fourier components of BO order. These findings indicate a strong coupling between BO and positional order that has not been studied in detail up to now.

preprint2012arXiv

Dynamics of colloidal crystals studied by pump-probe experiments at FLASH

We present a time-resolved infrared (IR) pump and extreme-ultraviolet (XUV) probe diffraction experiment to investigate ultrafast structural dynamics in colloidal crystals with picosecond resolution. The experiment was performed at the FLASH facility at DESY with a fundamental wavelength of 8 nm. In our experiment, the temporal changes of Bragg peaks were analyzed and their frequency components were calculated using Fourier analysis. Periodic modulations in the colloidal crystal were localized at a frequency of about 4-5 GHz. Based on the Lamb theory, theoretical calculations of vibrations of the isotropic elastic polystyrene spheres of 400 nm in size reveal a 5.07 GHz eigenfrequency of the ground (breathing) mode.

preprint2012arXiv

Impact of ultrafast electronic damage in single particle x-ray imaging experiments

In single particle coherent x-ray diffraction imaging experiments, performed at x-ray free-electron lasers (XFELs), samples are exposed to intense x-ray pulses to obtain single-shot diffraction patterns. The high intensity induces electronic dynamics on the femtosecond time scale in the system, which can reduce the contrast of the obtained diffraction patterns and adds an isotropic background. We quantify the degradation of the diffraction pattern from ultrafast electronic damage by performing simulations on a biological sample exposed to x-ray pulses with different parameters. We find that the contrast is substantially reduced and the background is considerably strong only if almost all electrons are removed from their parent atoms. This happens at fluences of at least one order of magnitude larger than provided at currently available XFEL sources.

preprint2012arXiv

Solution of the phase problem for coherent scattering from a disordered system of identical particles

While the implementation of single particle coherent diffraction imaging for non-crystalline particles is complicated by current limitations in photon flux, hit rate, and sample delivery a concept of many-particle coherent diffraction imaging offers an alternative way to overcome these difficulties. Here we present a direct, non-iterative approach for the recovery of the diffraction pattern corresponding to a single particle using coherent x-ray data collected from a two-dimensional (2D) disordered system of identical particles, that does not require a priori information about the particles and can be applied to a general case of particles without symmetry. The reconstructed single particle diffraction pattern can be directly used in common iterative phase retrieval algorithms to recover the structure of the particle.

preprint2012arXiv

Spectrometer for Hard X-Ray Free Electron Laser Based on Diffraction Focusing

X-ray free electron lasers (XFELs) generate sequences of ultra-short, spatially coherent pulses of x-ray radiation. We propose the diffraction focusing spectrometer (DFS), which is able to measure the whole energy spectrum of the radiation of a single XFEL pulse with an energy resolution of $ΔE/E\approx 2\times 10^{-6}$. This is much better than for most modern x-ray spectrometers. Such resolution allows one to resolve the fine spectral structure of the XFEL pulse. The effect of diffraction focusing occurs in a single crystal plate due to dynamical scattering, and is similar to focusing in a Pendry lens made from the metamaterial with a negative refraction index. Such a spectrometer is easier to operate than those based on bent crystals. We show that the DFS can be used in a wide energy range from 5 keV to 20 keV.

preprint2012arXiv

X-ray cross-correlation analysis applied to disordered two-dimensional systems

Angular x-ray cross-correlation analysis (XCCA) is an approach to study the structure of disordered systems using the results of coherent x-ray scattering experiments. Here, we present the results of simulations that validate our theoretical findings for XCCA obtained in a previous paper [M. Altarelli et al., Phys. Rev. B 82, 104207 (2010)]. We consider as a model two-dimensional (2D) disordered systems composed of non-interacting colloidal clusters with fivefold symmetry and with orientational and positional disorder. We simulate a coherent x-ray scattering in the far field from such disordered systems and perform the angular cross-correlation analysis of calculated diffraction data. The results of our simulations show the relation between the Fourier series representation of the cross-correlation functions (CCFs) and different types of correlations in disordered systems. The dependence of structural information extracted by XCCA on the density of disordered systems and the degree of orientational disorder of clusters is investigated. The statistical nature of the fluctuations of the CCFs in the model `single-shot' experiments is demonstrated and the potential of extracting structural information from the analysis of CCFs averaged over a set of diffraction patterns is discussed. We also demonstrate the effect of partial coherence of x-rays on the results of XCCA.

preprint2011arXiv

Three-dimensional structure of a single colloidal crystal grain studied by coherent x-ray diffraction

A coherent x-ray diffraction experiment was performed on an isolated colloidal crystal grain at the coherence beamline P10 at PETRA III. Using azimuthal rotation scans the three-dimensional (3D) scattered intensity in reciprocal space from the sample was measured. It includes several Bragg peaks as well as the coherent interference around these peaks. The analysis of the scattered intensity reveals the presence of a plane defect in a single grain of the colloidal sample. We confirm these findings by model simulations. In these simulations we also analyze the experimental conditions to phase 3D diffraction pattern from a single colloidal grain. This approach has the potential to produce a high resolution image of the sample revealing its inner structure, with possible structural defects.

preprint2010arXiv

X-ray cross-correlation analysis and local symmetries of disordered systems. I. General theory

In a recent article (P.Wochner et al., PNAS (2009)) x-ray scattering intensity correlations around a ring, in the speckle diffraction pattern of a colloidal glass, were shown to display a remarkable ~ cos(n $ϕ$) dependence on the angular coordinate $ϕ$ around the ring, with integer index n depending on the magnitude of the scattering wavevector. With an analytical derivation that preserves full generality in the Fraunhofer diffraction limit, we clarify the relationship of this result to previous x-ray studies of bond-orientation order, and provide a sound basis to the statement that the angular intensity correlations deliver information on local bond arrangements in a disordered (or partially ordered) system. We present a detailed analysis of the angular cross-correlation function and show its applicability for studies of wide range of structural properties of disordered systems, from local structure to spatial correlations between distant structural elements.

preprint2009arXiv

Analysis of Coherence Properties of 3-rd Generation Synchrotron Sources and Free-Electron Lasers

A general theoretical approach based on the results of statistical optics is used for the analysis of the transverse coherence properties of 3-rd generation synchrotron sources and x-ray free-electron lasers (XFEL). Correlation properties of the wavefields are calculated at different distances from an equivalent Gaussian Schell-model source. This model is used to describe coherence properties of the five meter undulator source at the synchrotron storage ring PETRA III. In the case of XFEL sources the decomposition of the statistical fields into a sum of independently propagating transverse modes is used for the analysis of the coherence properties of these new sources. A detailed calculation is performed for the parameters of the SASE1 undulator at the European XFEL. It is demonstrated that only a few modes contribute significantly to the total radiation field of that source.